AFNI program: afni_proc.py

Output of -help



===========================================================================
afni_proc.py        - generate a tcsh script for an AFNI process stream

Purpose: ~1~

   This program is meant to create single subject processing scripts for
   task, resting state or surface-based analyses.  The processing scripts
   are written in the tcsh language.

   The typical goal is to create volumes of aligned response magnitudes
   (stimulus beta weights) to use as input for a group analysis.

Inputs (only EPI is required): ~1~

   - anatomical dataset
   - EPI time series datasets
   - stimulus timing files
   - processing and design decisions:
       e.g. TRs to delete, blur size, censoring options, basis functions

Main outputs (many datasets are created): ~1~

   - for task-based analysis: stats dataset (and anat_final)
   - for resting-state analysis: errts datasets ("cleaned up" EPI)

Basic script outline: ~1~

   - copy all inputs to new 'results' directory
   - process data: e.g. despike,tshift/align/tlrc/volreg/blur/scale/regress
   - leave all (well, most) results there, so user can review processing
   - create @ss_review scripts to help user with basic quality control

The exact processing steps are controlled by the user, including which main
processing blocks to use, and their order.  See the 'DEFAULTS' section for
a description of the default options for each block.

The output script (when executed) would create a results directory, copy
input files into it, and perform all processing there.  So the user can
delete the results directory and modify/re-run the script at their whim.

Note that the user need not actually run the output script.  The user
should feel free to modify the script for their own evil purposes, or to
just compare the processing steps with those in their own scripts.  Also,
even if a user is writing their own processing scripts, it is a good idea
to get some independent confirmation of the processing, such as by using
afni_proc.py to compare the results on occasion.

The text interface can be accessed via the -ask_me option.  It invokes a
question & answer session, during which this program sets user options on
the fly.  The user may elect to enter some of the options on the command
line, even if using -ask_me.  See "-ask_me EXAMPLES", below.

** However, -ask_me has not been touched in many years.  I suggest starting
   with the 'modern' examples (for task/rest/surface), or by using the
   uber_subject.py GUI (graphical user interface) to generate an initial
   afni_proc.py command script.

   See uber_subject.py -help (or just start the GUI) for details.

==================================================
SECTIONS: order of sections in the "afni_proc.py -help" output ~1~

    program introduction    : (above) basic overview of afni_proc.py
    PROCESSING BLOCKS       : list of possible processing blocks
    DEFAULTS                : basic default operations, per block
    EXAMPLES                : various examples of running this program
    NOTE sections           : details on various topics
        GENERAL ANALYSIS NOTE, QUALITY CONTROL NOTE,
        RESTING STATE NOTE, FREESURFER NOTE,
        TIMING FILE NOTE, MASKING NOTE,
        ANAT/EPI ALIGNMENT CASES NOTE, ANAT/EPI ALIGNMENT CORRECTIONS NOTE,
        WARP TO TLRC NOTE,
        RETROICOR NOTE, MULTI ECHO NOTE,
        RUNS OF DIFFERENT LENGTHS NOTE, SCRIPT EXECUTION NOTE
    OPTIONS                 : descriptions of all program options
        informational       : options to get quick info and quit
        general execution   : options not specific to a processing block
        block options       : specific to blocks, in default block order

==================================================
PROCESSING BLOCKS (of the output script): ~1~

The output script will go through the following steps, unless the user
specifies otherwise.

automatic blocks (the tcsh script will always perform these): ~2~

    setup       : check subject arg, set run list, create output dir, and
                  copy stim files
    tcat        : copy input datasets and remove unwanted initial TRs

default blocks (the user may skip these, or alter their order): ~2~

    tshift      : slice timing alignment on volumes (default is -time 0)
    volreg      : volume registration (default to third volume)
    blur        : blur each volume (default is 4mm fwhm)
    mask        : create a 'brain' mask from the EPI data (dilate 1 voxel)
    scale       : scale each run mean to 100, for each voxel (max of 200)
    regress     : regression analysis (default is GAM, peak 1, with motion
                  params)

optional blocks (the default is to _not_ apply these blocks) ~2~

    align       : align EPI anat anatomy (via align_epi_anat.py)
    combine     : combine echoes into one
    despike     : truncate spikes in each voxel's time series
    empty       : placeholder for some user command (uses 3dTcat as sample)
    ricor       : RETROICOR - removal of cardiac/respiratory regressors
    surf        : project volumetric data into the surface domain
    tlrc        : warp anat to standard space

implicit blocks (controlled by program, added when appropriate) ~2~

    blip                   : perform B0 distortion correction
    outcount               : temporal outlier detection
    quality control review : generate QC review scripts and HTML report
    @radial_correlate      : QC - compute local neighborhood correlations
    uniformity correction  : anatomical uniformity correction

==================================================
DEFAULTS: basic defaults for each block (blocks listed in default order) ~1~

    A : denotes automatic block that is not a 'processing' option
    D : denotes a default processing block (others must be requested)

A   setup:    - use 'SUBJ' for the subject id
                    (option: -subj_id SUBJ)
              - create a t-shell script called 'proc_subj'
                    (option: -script proc_subj)
              - use results directory 'SUBJ.results'
                    (option: -out_dir SUBJ.results)

A   tcat:     - do not remove any of the first TRs

    despike:  - NOTE: by default, this block is _not_ used
              - automasking is not done (requires -despike_mask)

    ricor:    - NOTE: by default, this block is _not_ used
              - polort based on twice the actual run length
              - solver is OLSQ, not REML
              - do not remove any first TRs from the regressors

D   tshift:   - align slices to the beginning of the TR
              - use quintic interpolation for time series resampling
                    (option: -tshift_interp -quintic)

    align:    - align the anatomy to match the EPI
                (also required for the option of aligning EPI to anat)

    tlrc:     - use TT_N27+tlrc as the base (-tlrc_base TT_N27+tlrc)
              - no additional suffix (-tlrc_suffix NONE)
              - use affine registration (no -tlrc_NL_warp)

D   volreg:   - align to third volume of first run, -zpad 1
                    (option: -volreg_align_to third)
                    (option: -volreg_zpad 1)
              - use cubic interpolation for volume resampling
                    (option: -volreg_interp -cubic)
              - apply motion params as regressors across all runs at once
              - do not align EPI to anat
              - do not warp to standard space

    combine:  - combine methods using OC (optimally combined)

D   blur:     - blur data using a 4 mm FWHM filter with 3dmerge
                    (option: -blur_filter -1blur_fwhm)
                    (option: -blur_size 4)
                    (option: -blur_in_mask no)

D   mask:     - create a union of masks from 3dAutomask on each run
              - not applied in regression without -regress_apply_mask
              - if possible, create a subject anatomy mask
              - if possible, create a group anatomy mask (tlrc base)

D   scale:    - scale each voxel to mean of 100, clip values at 200

D   regress:  - use GAM regressor for each stim
                    (option: -regress_basis)
              - compute the baseline polynomial degree, based on run length
                    (e.g. option: -regress_polort 2)
              - do not censor large motion
              - output fit time series
              - output ideal curves for GAM/BLOCK regressors
              - output iresp curves for non-GAM/non-BLOCK regressors

    empty:    - do nothing (just copy the data using 3dTcat)


==================================================
EXAMPLES (options can be provided in any order): ~1~

        Example 1. Minimum use. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              merely shows how simple a command can be)

           Provide datasets and stim files (or stim_times files).  Note that a
           dataset suffix (e.g. HEAD) must be used with wildcards, so that
           datasets are not applied twice.  In this case, a stim_file with many
           columns is given, where the script to changes it to stim_times files.
           
        --------------------------
        last mod date : 2008.12.10
        keywords      : obsolete, task
        --------------------------

        afni_proc.py                                                         \
            -dsets               epiRT*.HEAD                                 \
            -regress_stim_files  stims.1D
 

        Example 2. Very simple. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper)

           Use all defaults, except remove 3 TRs and use basis
           function BLOCK(30,1).  The default basis function is GAM.
            
        --------------------------
        last mod date : 2009.05.28
        keywords      : obsolete, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                sb23.e2.simple                           \
            -dsets                  sb23/epi_r??+orig.HEAD                   \
            -tcat_remove_first_trs  3                                        \
            -regress_stim_times     sb23/stim_files/blk_times.*.1D           \
            -regress_basis          'BLOCK(30,1)'
 

        Example 3. Formerly a simple class example. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper)

           Copy the anatomy into the results directory, register EPI data to
           the last TR, specify stimulus labels, compute blur estimates, and
           provide GLT options directly to 3dDeconvolve.  The GLTs will be
           ignored after this, as they take up too many lines.
            
        --------------------------
        last mod date : 2009.05.28
        keywords      : obsolete, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                 sb23.blk                                \
            -dsets                   sb23/epi_r??+orig.HEAD                  \
            -copy_anat               sb23/sb23_mpra+orig                     \
            -tcat_remove_first_trs   3                                       \
            -volreg_align_to         last                                    \
            -regress_stim_times      sb23/stim_files/blk_times.*.1D          \
            -regress_stim_labels     tneg tpos tneu eneg epos eneu fneg fpos \
                                     fneu                                    \
            -regress_basis           'BLOCK(30,1)'                           \
            -regress_opts_3dD        -gltsym 'SYM: +eneg -fneg'              \
                                     -glt_label 1 eneg_vs_fneg               \
                                     -gltsym                                 \
                                     'SYM: 0.5*fneg 0.5*fpos -1.0*fneu'      \
                                     -glt_label 2 face_contrast              \
                                     -gltsym                                 \
                                     'SYM: tpos epos fpos -tneg -eneg -fneg' \
                                     -glt_label 3 pos_vs_neg                 \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 4. Similar to 3, but specify the processing blocks. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper)

           Adding despike and tlrc, and removing tshift.  Note that
           the tlrc block is to run @auto_tlrc on the anat.  Ignore the GLTs.
           
        --------------------------
        last mod date : 2009.05.28
        keywords      : obsolete, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                 sb23.e4.blocks                          \
            -dsets                   sb23/epi_r??+orig.HEAD                  \
            -blocks                  despike volreg blur mask scale regress  \
                                     tlrc                                    \
            -copy_anat               sb23/sb23_mpra+orig                     \
            -tcat_remove_first_trs   3                                       \
            -regress_stim_times      sb23/stim_files/blk_times.*.1D          \
            -regress_stim_labels     tneg tpos tneu eneg epos eneu fneg fpos \
                                     fneu                                    \
            -regress_basis           'BLOCK(30,1)'                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 5a. RETROICOR, resting state data. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              just a terribly simple example using ricor)

           Assuming the class data is for resting-state and that we have the
           appropriate slice-based regressors from RetroTS.py, apply the
           despike and ricor processing blocks.  Note that '-do_block' is used
           to add non-default blocks into their default positions.  Here the
           'despike' and 'ricor' processing blocks would come before 'tshift'.

           Remove 3 TRs from the ricor regressors to match the EPI data.  Also,
           since degrees of freedom are not such a worry, regress the motion
           parameters per-run (each run gets a separate set of 6 regressors).

           The regression will use 81 basic regressors (all of "no interest"),
           with 13 retroicor regressors being removed during preprocessing:

                 27 baseline  regressors ( 3 per run * 9 runs)
                 54 motion    regressors ( 6 per run * 9 runs)

           To example #3, add -do_block, -ricor_* and -regress_motion_per_run.
           
        --------------------------
        last mod date : 2009.05.28
        keywords      : obsolete, physio, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                 sb23.e5a.ricor                          \
            -dsets                   sb23/epi_r??+orig.HEAD                  \
            -do_block                despike ricor                           \
            -tcat_remove_first_trs   3                                       \
            -ricor_regs_nfirst       3                                       \
            -ricor_regs              sb23/RICOR/r*.slibase.1D                \
            -regress_motion_per_run

           If tshift, blurring and masking are not desired, consider replacing
           the -do_block option with an explicit list of blocks:

                -blocks despike ricor volreg regress
           

        Example 5b. RETROICOR, while running a normal regression. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              another overly simple example using ricor)

           Add the ricor regressors to a normal regression-based processing
           stream.  Apply the RETROICOR regressors across runs (so using 13
           concatenated regressors, not 13*9).  Note that concatenation is
           normally done with the motion regressors too.

           To example #3, add -do_block and three -ricor options.
           
        --------------------------
        last mod date : 2009.05.28
        keywords      : obsolete, physio, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                 sb23.e5b.ricor                          \
            -dsets                   sb23/epi_r??+orig.HEAD                  \
            -do_block                despike ricor                           \
            -copy_anat               sb23/sb23_mpra+orig                     \
            -tcat_remove_first_trs   3                                       \
            -ricor_regs_nfirst       3                                       \
            -ricor_regs              sb23/RICOR/r*.slibase.1D                \
            -ricor_regress_method    across-runs                             \
            -volreg_align_to         last                                    \
            -regress_stim_times      sb23/stim_files/blk_times.*.1D          \
            -regress_stim_labels     tneg tpos tneu eneg epos eneu fneg fpos \
                                     fneu                                    \
            -regress_basis           'BLOCK(30,1)'                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts

           Also consider adding -regress_bandpass.
           

        Example 5c. RETROICOR: censor and band pass. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper, no BP)

           This is an example of how we might currently suggest analyzing
           resting state data.  If no RICOR regressors exist, see example 9
           (or just remove any ricor options).

           Censoring due to motion has long been considered appropriate in
           BOLD FMRI analysis, but is less common for those doing bandpass
           filtering in RS FMRI because the FFT requires one to either break
           the time axis (evil) or to replace the censored data with something
           probably inappropriate.

           Instead, it is slow (no FFT, but maybe SFT :) but effective to
           regress frequencies within the regression model, where censoring
           is simple.

           Note: band passing in the face of RETROICOR is questionable.  It may
                 be questionable in general.  To skip bandpassing, remove the
                 -regress_bandpass option line.

           Also, align EPI to anat and warp to standard space.
           
        --------------------------
        last mod date : 2016.05.03
        keywords      : obsolete, physio, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  sb23.e5a.ricor                         \
            -dsets                    sb23/epi_r??+orig.HEAD                 \
            -blocks                   despike ricor tshift align tlrc volreg \
                                      blur mask regress                      \
            -copy_anat                sb23/sb23_mpra+orig                    \
            -tcat_remove_first_trs    3                                      \
            -ricor_regs_nfirst        3                                      \
            -ricor_regs               sb23/RICOR/r*.slibase.1D               \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -blur_size                6                                      \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.2                                    \
            -regress_bandpass         0.01 0.1                               \
            -regress_apply_mot_types  demean deriv                           \
            -regress_run_clustsim     no                                     \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 6. A simple task example, based on AFNI_data6. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              meant to be fast, but not complete, e.g. NL warp)
              (              prefer: see Example 6b)

           This example has changed to more closely correspond with the
           the class analysis example, AFNI_data6/FT_analysis/s05.ap.uber.

           The tshift block will interpolate each voxel time series to adjust
           for differing slice times, where the result is more as if each
           entire volume were acquired at the beginning of the TR.

           The 'align' block implies using align_epi_anat.py to align the
           anatomy with the EPI.  Here, the EPI base is first unifized locally.
           Additional epi/anat alignment options specify using lpc+ZZ for the
           cost function (more robust than simply lpc), -giant_move (in case
           the anat and EPI start a bit far apart), and -check_flip, to try to
           verify whether EPI left and right agree with the anatomy.
           This block computes the anat to EPI transformation matrix, which
           will be inverted in the volreg block, based on -volreg_align_e2a.

           Also, compute the transformation of the anatomy to MNI space, using
           affine registration (for speed in this simple example) to align to
           the 2009c template.

           In the volreg block, align the EPI to the MIN_OUTLIER volume (a
           low-motion volume, determined based on the data).  Then concatenate
           all EPI transformations, warping the EPI to standard space in one
           step (without multiple resampling operations), combining:

              EPI  ->  EPI base  ->  anat  ->  MNI 2009c template

           The standard space transformation is included by specifying option
           -volreg_tlrc_warp.

           A 4 mm blur is applied, to keep it very light (about 1.5 times the
           voxel size).

           The regression model is based on 2 conditions, each lasting 20 s
           per event, modeled by convolving a 20 s boxcar function with the
           BLOCK basis function, specified as BLOCK(20,1) to make the regressor
           unit height (height 1).

           One extra general linear test (GLT) is included, contrasting the
           visual reliable condition (vis) with auditory reliable (aud).

           Motion regression will be per run (using one set of 6 regressors for
           each run, i.e. 18 regressors in this example).

           The regression includes censoring of large motion (>= 0.3 ~mm
           between successive time points, based on the motion parameters),
           as well as censoring of outlier time points, where at least 5% of
           the brain voxels are computed as outliers.

           The regression model starts as a full time series, for time
           continuity, before censored time points are removed.  The output
           errts will be zero at censored time points (no error there), and so
           the output fit times series (fitts) will match the original data.

           The model fit time series (fitts) will be computed AFTER the linear
           regression, to save RAM on class laptops.

           Create sum_ideal.1D, as the sum of all non-baseline regressors, for
           quality control.

           Estimate the blur in the residual time series.  The resulting 3 ACF
           parameters can be averaged across subjects for cluster correction at
           the group level.

           Skip running the Monte Carlo cluster simulation example (which would
           specify minimum cluster sizes for cluster significance, based on the
           ACF parameters and mask), for speed.

           Once the proc script is created, execute it.
           
        --------------------------
        last mod date : 2020.02.15
        keywords      : task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT.e6                                  \
            -copy_anat                FT/FT_anat+orig                        \
            -dsets                    FT/FT_epi_r?+orig.HEAD                 \
            -blocks                   tshift align tlrc volreg mask blur     \
                                      scale regress                          \
            -radial_correlate_blocks  tcat volreg                            \
            -tcat_remove_first_trs    2                                      \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_compute_tsnr      yes                                    \
            -mask_epi_anat            yes                                    \
            -blur_size                4.0                                    \
            -regress_stim_times       FT/AV1_vis.txt FT/AV2_aud.txt          \
            -regress_stim_labels      vis aud                                \
            -regress_basis            'BLOCK(20,1)'                          \
            -regress_opts_3dD         -jobs 2                                \
                                      -gltsym 'SYM: vis -aud'                \
                                      -glt_label 1 V-A                       \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_compute_fitts                                           \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     no                                     \
            -html_review_style        pythonic                               \
            -execute

         * One could also use ANATICOR with task (e.g. -regress_anaticor_fast)
           in the case of -regress_reml_exec.  3dREMLfit supports voxelwise
           regression, but 3dDeconvolve does not.
             

        Example 6b. A modern task example, with preferable options. ~2~

              (recommended?  yes, reasonable for a complete analysis)

           GOOD TO CONSIDER

           This is based on Example 6, but is more complete.
           Example 6 is meant to run quickly, as in an AFNI bootcamp setting.
           Example 6b is meant to process more as we might suggest.

              - apply -check_flip in align_epi_anat.py, to monitor consistency
              - apply non-linear registration to MNI template, using output
                from @SSwarper:
                  o apply skull-stripped anat in -copy_anat
                  o apply original anat as -anat_follower (QC, for comparison)
                  o pass warped anat and transforms via -tlrc_NL_warped_dsets,
                    to apply those already computed transformations
              - use -mask_epi_anat to tighten the EPI mask (for QC),
                intersecting it (full_mask) with the anat mask (mask_anat)
              - use 3dREMLfit for the regression, to account for temporal
                autocorrelation in the noise
                (-regress_3dD_stop, -regress_reml_exec)
              - generate the HTML QC report using the nicer pythonic functions
                (requires matplotlib)
           
        --------------------------
        last mod date : 2020.02.15
        keywords      : complete, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT.e6b                                 \
            -copy_anat                Qwarp/anat_warped/anatSS.FT.nii        \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat FT/FT_anat+orig      \
            -dsets                    FT/FT_epi_r?+orig.HEAD                 \
            -blocks                   tshift align tlrc volreg mask blur     \
                                      scale regress                          \
            -radial_correlate_blocks  tcat volreg                            \
            -tcat_remove_first_trs    2                                      \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     Qwarp/anat_warped/anatQQ.FT.nii        \
                                      Qwarp/anat_warped/anatQQ.FT.aff12.1D   \
                                      Qwarp/anat_warped/anatQQ.FT_WARP.nii   \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_compute_tsnr      yes                                    \
            -mask_epi_anat            yes                                    \
            -blur_size                4.0                                    \
            -regress_stim_times       FT/AV1_vis.txt FT/AV2_aud.txt          \
            -regress_stim_labels      vis aud                                \
            -regress_basis            'BLOCK(20,1)'                          \
            -regress_opts_3dD         -jobs 2                                \
                                      -gltsym 'SYM: vis -aud'                \
                                      -glt_label 1 V-A                       \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_3dD_stop                                                \
            -regress_reml_exec                                               \
            -regress_compute_fitts                                           \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     no                                     \
            -html_review_style        pythonic                               \
            -execute

           To compare one's own command against this one, consider adding
                -compare_opts 'example 6b'
           to the end of (or anywhere in) the current command, as in:

                afni_proc.py ... my options ...   -compare_opts 'example 6b'
           

        Example 7. Apply some esoteric options. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              e.g. NL warp without @SSwarper)
              (              prefer: see Example 6b)

           a. Blur only within the brain, as far as an automask can tell.  So
              add -blur_in_automask to blur only within an automatic mask
              created internally by 3dBlurInMask (akin to 3dAutomask).

           b. Let the basis functions vary.  For some reason, we expect the
              BOLD responses to the telephone classes to vary across the brain.
              So we have decided to use TENT functions there.  Since the TR is
              3.0s and we might expect up to a 45 second BOLD response curve,
              use 'TENT(0,45,16)' for those first 3 out of 9 basis functions.

              This means using -regress_basis_multi instead of -regress_basis,
              and specifying all 9 basis functions appropriately.

           c. Use amplitude modulation.

              We expect responses to email stimuli to vary proportionally with
              the number of punctuation characters used in the message (in
              certain brain regions).  So we will use those values as auxiliary
              parameters 3dDeconvolve by marrying the parameters to the stim
              times (using 1dMarry).

              Use -regress_stim_types to specify that the epos/eneg/eneu stim
              classes should be passed to 3dDeconvolve using -stim_times_AM2.

           d. Not only censor motion, but censor TRs when more than 10% of the
              automasked brain are outliers.  So add -regress_censor_outliers.

           e. Include both de-meaned and derivatives of motion parameters in
              the regression.  So add '-regress_apply_mot_types demean deriv'.

           f. Output baseline parameters so we can see the effect of motion.
              So add -bout under option -regress_opts_3dD.

           g. Save on RAM by computing the fitts only after 3dDeconvolve.
              So add -regress_compute_fitts.

           h. Speed things up.  Have 3dDeconvolve use 4 CPUs and skip the
              single subject 3dClustSim execution.  So add '-jobs 4' to the
              -regress_opts_3dD option and add '-regress_run_clustsim no'.
           
        --------------------------
        last mod date : 2020.01.08
        keywords      : task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  sb23.e7.esoteric                       \
            -dsets                    sb23/epi_r??+orig.HEAD                 \
            -blocks                   tshift align tlrc volreg blur mask     \
                                      scale regress                          \
            -copy_anat                sb23/sb23_mpra+orig                    \
            -tcat_remove_first_trs    3                                      \
            -align_opts_aea           -cost lpc+ZZ                           \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -blur_size                4                                      \
            -blur_in_automask                                                \
            -regress_stim_times       sb23/stim_files/blk_times.*.1D         \
            -regress_stim_types       times times times AM2 AM2 AM2 times    \
                                      times times                            \
            -regress_stim_labels      tneg tpos tneu eneg epos eneu fneg     \
                                      fpos fneu                              \
            -regress_basis_multi      'BLOCK(30,1)' 'TENT(0,45,16)'          \
                                      'BLOCK(30,1)' 'BLOCK(30,1)'            \
                                      'TENT(0,45,16)' 'BLOCK(30,1)'          \
                                      'BLOCK(30,1)' 'TENT(0,45,16)'          \
                                      'BLOCK(30,1)'                          \
            -regress_apply_mot_types  demean deriv                           \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.1                                    \
            -regress_compute_fitts                                           \
            -regress_opts_3dD         -bout -gltsym 'SYM: +eneg -fneg'       \
                                      -glt_label 1 eneg_vs_fneg              \
                                      -jobs 4                                \
            -regress_run_clustsim     no                                     \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 8. Surface-based analysis. ~2~

              (recommended?  yes, reasonable for a complete analysis)

           This example is intended to be run from AFNI_data6/FT_analysis.
           It is provided with the class data in file s03.ap.surface.

           Add -surf_spec and -surf_anat to provide the required spec and
           surface volume datasets.  The surface volume will be aligned to
           the current anatomy in the processing script.  Two spec files
           (lh and rh) are provided, one for each hemisphere (via wildcard).

           Also, specify a (resulting) 6 mm FWHM blur via -blur_size.  This
           does not add a blur, but specifies a resulting blur level.  So
           6 mm can be given directly for correction for multiple comparisons
           on the surface.

           Censor per-TR motion above 0.3 mm.

           Note that no -regress_est_blur_errts option is given, since that
           applies to the volume only (and since the 6 mm blur is a resulting
           blur level, so the estimates are not needed).

           The -blocks option is provided, but it is the same as the default
           for surface-based analysis, so is not really needed here.  Note that
           the 'surf' block is added and the 'mask' block is removed from the
           volume-based defaults.

           important options:

                -blocks         : includes surf, but no mask
                                  (default blocks for surf, so not needed)
                -surf_anat      : volume aligned with surface
                -surf_spec      : spec file(s) for surface

           Note: one would probably want to use standard mesh surfaces here.
                 This example will be updated with them in the future.
            
        --------------------------
        last mod date : 2017.09.12
        keywords      : complete, surface, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                 FT.surf                                 \
            -blocks                  tshift align volreg surf blur scale     \
                                     regress                                 \
            -copy_anat               FT/FT_anat+orig                         \
            -dsets                   FT/FT_epi_r?+orig.HEAD                  \
            -surf_anat               FT/SUMA/FTmb_SurfVol+orig               \
            -surf_spec               FT/SUMA/FTmb_?h.spec                    \
            -tcat_remove_first_trs   2                                       \
            -align_opts_aea          -cost lpc+ZZ                            \
                                     -giant_move                             \
            -volreg_align_to         MIN_OUTLIER                             \
            -volreg_align_e2a                                                \
            -blur_size               6                                       \
            -regress_stim_times      FT/AV1_vis.txt FT/AV2_aud.txt           \
            -regress_stim_labels     vis aud                                 \
            -regress_basis           'BLOCK(20,1)'                           \
            -regress_motion_per_run                                          \
            -regress_censor_motion   0.3                                     \
            -regress_opts_3dD        -jobs 2                                 \
                                     -gltsym 'SYM: vis -aud'                 \
                                     -glt_label 1 V-A
 

        Example 9. Resting state analysis with censoring and band passing. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              e.g. has band pass, no @SSwarper)
              (              prefer: see Example 11)

           With censoring and bandpass filtering.

           This is our suggested way to do preprocessing for resting state
           analysis, under the assumption that no cardio/physio recordings
           were made (see example 5 for cardio files).

           Censoring due to motion has long been considered appropriate in
           BOLD FMRI analysis, but is less common for those doing bandpass
           filtering in RS FMRI because the FFT requires one to either break
           the time axis (evil) or to replace the censored data with something
           probably inappropriate.

           Instead, it is slow (no FFT, but maybe SFT :) but effective to
           regress frequencies within the regression model, where censoring
           is simple.

           inputs: anat, EPI
           output: errts dataset (to be used for correlation)

           special processing:
              - despike, as another way to reduce motion effect
                 (see block despike)
              - censor motion TRs at the same time as bandpassing data
                 (see -regress_censor_motion, -regress_bandpass)
              - regress motion parameters AND derivatives
                 (see -regress_apply_mot_types)

           Note: for resting state data, a more strict threshold may be a good
                 idea, since motion artifacts should play a bigger role than in
                 a task-based analysis.

                 So the typical suggestion of motion censoring at 0.3 for task
                 based analysis has been changed to 0.2 for this resting state
                 example, and censoring of outliers has also been added, at a
                 value of 5% of the brain mask.

                 Outliers are typically due to motion, and may capture motion
                 in some cases where the motion parameters do not, because
                 motion is not generally a whole-brain-between-TRs event.

           Note: if regressing out regions of interest, either create the ROI
                 time series before the blur step, or remove blur from the list
                 of blocks (and apply any desired blur after the regression).

           Note: it might be reasonable to estimate the blur using epits rather
                 than errts in the case of bandpassing.  Both options are
                 included here.

           Note: scaling is optional here.  While scaling has no direct effect
                 on voxel correlations, it does have an effect on ROI averages
                 used for correlations.

           Other options to consider: -tlrc_NL_warp, -anat_uniform_method
            
        --------------------------
        last mod date : 2019.02.26
        keywords      : rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  subj123                                \
            -dsets                    epi_run1+orig.HEAD                     \
            -copy_anat                anat+orig                              \
            -blocks                   despike tshift align tlrc volreg blur  \
                                      mask scale regress                     \
            -tcat_remove_first_trs    3                                      \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -blur_size                4                                      \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_bandpass         0.01 0.1                               \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 9b. Resting state analysis with ANATICOR. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              e.g. has band pass, no @SSwarper)
              (              prefer: see Example 11)

           Like example #9, but also regress out the signal from locally
           averaged white matter.  The only change is adding the option
           -regress_anaticor.

           Note that -regress_anaticor implies options -mask_segment_anat and
           -mask_segment_erode.
            
        --------------------------
        last mod date : 2020.01.08
        keywords      : rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  subj123                                \
            -dsets                    epi_run1+orig.HEAD                     \
            -copy_anat                anat+orig                              \
            -blocks                   despike tshift align tlrc volreg blur  \
                                      mask scale regress                     \
            -tcat_remove_first_trs    3                                      \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -blur_size                4                                      \
            -regress_anaticor                                                \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_bandpass         0.01 0.1                               \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 10. Resting state analysis, with tissue-based regressors. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              e.g. missing @SSwarper)
              (              prefer: see Example 11)

           Like example #9, but also regress the eroded white matter averages.
           The WMe mask come from the Classes dataset, created by 3dSeg via the
           -mask_segment_anat and -mask_segment_erode options.

        ** While -mask_segment_anat also creates a CSF mask, that mask is ALL
           CSF, not just restricted to the ventricles, for example.  So it is
           probably not appropriate for use in tissue-based regression.

           CSFe was previously used as an example of what one could do, but as
           it is not advised, it has been removed.

           Also, align to minimum outlier volume, and align to the anatomy
           using cost function lpc+ZZ.

           Note: it might be reasonable to estimate the blur using epits rather
                 than errts in the case of bandpassing.  Both options are
                 included here.
            
        --------------------------
        last mod date : 2020.01.08
        keywords      : rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  subj123                                \
            -dsets                    epi_run1+orig.HEAD                     \
            -copy_anat                anat+orig                              \
            -blocks                   despike tshift align tlrc volreg blur  \
                                      mask scale regress                     \
            -tcat_remove_first_trs    3                                      \
            -align_opts_aea           -cost lpc+ZZ                           \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -blur_size                4                                      \
            -mask_epi_anat            yes                                    \
            -mask_segment_anat        yes                                    \
            -mask_segment_erode       yes                                    \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_bandpass         0.01 0.1                               \
            -regress_apply_mot_types  demean deriv                           \
            -regress_ROI              WMe                                    \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts
 

        Example 10b. Resting state analysis, as 10a with 3dRSFC. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              prefer: see Example 11)
              (         ***        : use censoring and 3dLombScargle)

            This is for band passing and computation of ALFF, etc.

          * This will soon use a modified 3dRSFC.

            Like example #10, but add -regress_RSFC to bandpass via 3dRSFC.
            Skip censoring and regression band passing because of the bandpass
            operation in 3dRSFC.

            To correspond to common tractography, this example stays in orig
            space (no 'tlrc' block, no -volreg_tlrc_warp option).  Of course,
            going to standard space is an option.
            
        --------------------------
        last mod date : 2019.02.13
        keywords      : rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  subj123                                \
            -dsets                    epi_run1+orig.HEAD                     \
            -copy_anat                anat+orig                              \
            -blocks                   despike tshift align volreg blur mask  \
                                      scale regress                          \
            -tcat_remove_first_trs    3                                      \
            -volreg_align_e2a                                                \
            -blur_size                6.0                                    \
            -mask_apply               epi                                    \
            -mask_segment_anat        yes                                    \
            -mask_segment_erode       yes                                    \
            -regress_bandpass         0.01 0.1                               \
            -regress_apply_mot_types  demean deriv                           \
            -regress_ROI              WMe                                    \
            -regress_RSFC                                                    \
            -regress_run_clustsim     no                                     \
            -regress_est_blur_errts
 

        Example 11. Resting state analysis (now even more modern :). ~2~

              (recommended?  yes, reasonable for a complete analysis)

         o Yes, censor (outliers and motion) and despike.
         o Align the anatomy and EPI using the lpc+ZZ cost function, rather
           than the default lpc one.  Apply -giant_move, in case the datasets
           do not start off well-aligned.  Include -check_flip for good measure.
           A locally unifized EPI base is used for anatomical registration.
         o Register EPI volumes to the one which has the minimum outlier
              fraction (so hopefully the least motion).
         o Use non-linear registration to MNI template (non-linear 2009c).
           * This adds a lot of processing time.
           * Let @SSwarper align to template MNI152_2009_template_SSW.nii.gz.
             Then use the resulting datasets in the afni_proc.py command below
             via -tlrc_NL_warped_dsets.
                  @SSwarper -input FT_anat+orig        \
                            -subid FT                  \
                            -odir  FT_anat_warped      \
                            -base  MNI152_2009_template_SSW.nii.gz

            - The SS (skull-stripped) can be given via -copy_anat, and the
              with-skull unifized anatU can be given as a follower.
         o No bandpassing.
         o Use fast ANATICOR method (slightly different from default ANATICOR).
         o Use FreeSurfer segmentation for:
             - regression of first 3 principal components of lateral ventricles
             - ANATICOR white matter mask (for local white matter regression)
           * For details on how these masks were created, see "FREESURFER NOTE"
             in the help, as it refers to this "Example 11".
         o Erode FS white matter and ventricle masks before application.
         o Bring along FreeSurfer parcellation datasets:
             - aaseg : NN interpolated onto the anatomical grid
             - aeseg : NN interpolated onto the EPI        grid
           * These 'aseg' follower datasets are just for visualization,
             they are not actually required for the analysis.
         o Compute average correlation volumes of the errts against the
           the gray matter (aeseg) and ventricle (FSVent) masks.
         o Run @radial_correlate at the ends of the tcat, volreg and regress
           blocks.  If ANATICOR is being used to remove a scanner artifact,
           the errts radcor images might show the effect of this.

           Note: it might be reasonable to use either set of blur estimates
                 here (from epits or errts).  The epits (uncleaned) dataset
                 has all of the noise (though what should be considered noise
                 in this context is not clear), while the errts is motion
                 censored.  For consistency in resting state, it would be
                 reasonable to stick with epits.  They will likely be almost
                 identical.
            
        --------------------------
        last mod date : 2022.10.06
        keywords      : complete, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT.11.rest                             \
            -blocks                   despike tshift align tlrc volreg blur  \
                                      mask scale regress                     \
            -radial_correlate_blocks  tcat volreg regress                    \
            -copy_anat                anatSS.FT.nii                          \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat anatU.FT.nii         \
            -anat_follower_ROI        aaseg anat                             \
                                      aparc.a2009s+aseg_REN_all.nii.gz       \
            -anat_follower_ROI        aeseg epi                              \
                                      aparc.a2009s+aseg_REN_all.nii.gz       \
            -anat_follower_ROI        FSvent epi fs_ap_latvent.nii.gz        \
            -anat_follower_ROI        FSWe epi fs_ap_wm.nii.gz               \
            -anat_follower_erode      FSvent FSWe                            \
            -dsets                    FT_epi_r?+orig.HEAD                    \
            -tcat_remove_first_trs    2                                      \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     anatQQ.FT.nii anatQQ.FT.aff12.1D       \
                                      anatQQ.FT_WARP.nii                     \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -blur_size                4                                      \
            -mask_epi_anat            yes                                    \
            -regress_motion_per_run                                          \
            -regress_ROI_PC           FSvent 3                               \
            -regress_ROI_PC_per_run   FSvent                                 \
            -regress_make_corr_vols   aeseg FSvent                           \
            -regress_anaticor_fast                                           \
            -regress_anaticor_label   FSWe                                   \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -html_review_style        pythonic
 

        Example 11b. Similar to 11, but without FreeSurfer. ~2~

              (recommended?  yes, reasonable for a complete analysis)
              (              if this ventricle extraction method seems okay)

         AFNI currently does not have a good program to extract ventricles.
         But it can make a CSF mask that includes them.  So without FreeSurfer,
         one could import a ventricle mask from the template (e.g. for TT space,
         using TT_desai_dd_mpm+tlrc).  For example, assuming Talairach space
         (and a 2.5 mm^3 final voxel grid) for the analysis, one could create a
         ventricle mask as follows:

                3dcalc -a ~/abin/TT_desai_dd_mpm+tlrc                       \
                       -expr 'amongst(a,152,170)' -prefix template_ventricle
                3dresample -dxyz 2.5 2.5 2.5 -inset template_ventricle+tlrc \
                       -prefix template_ventricle_2.5mm

         o Be explicit with 2.5mm, using '-volreg_warp_dxyz 2.5'.
         o Use template TT_N27+tlrc, to be aligned with the desai atlas.
         o No -anat_follower options, but use -mask_import to import the
           template_ventricle_2.5mm dataset (and call it Tvent).
         o Use -mask_intersect to intersect ventricle mask with the subject's
           CSFe mask, making a more reliable subject ventricle mask (Svent).
         o Ventricle principle components are created as per-run regressors.
         o Make WMe and Svent correlation volumes, which are just for
           entertainment purposes anyway.
         o Run the cluster simulation.
            
        --------------------------
        last mod date : 2020.01.17
        keywords      : complete, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT.11b.rest                            \
            -blocks                   despike tshift align tlrc volreg blur  \
                                      mask scale regress                     \
            -copy_anat                FT_anat+orig                           \
            -dsets                    FT_epi_r?+orig.HEAD                    \
            -tcat_remove_first_trs    2                                      \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                TT_N27+tlrc                            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_warp_dxyz         2.5                                    \
            -blur_size                4                                      \
            -mask_segment_anat        yes                                    \
            -mask_segment_erode       yes                                    \
            -mask_import              Tvent template_ventricle_2.5mm+tlrc    \
            -mask_intersect           Svent CSFe Tvent                       \
            -mask_epi_anat            yes                                    \
            -regress_motion_per_run                                          \
            -regress_ROI_PC           Svent 3                                \
            -regress_ROI_PC_per_run   Svent                                  \
            -regress_make_corr_vols   WMe Svent                              \
            -regress_anaticor_fast                                           \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     yes
 

        Example 12. background: Multi-echo data processing. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              incomplete - just shows basic ME options)
              (              prefer: see Example 13)

         Processing multi-echo data should be similar to single echo data,
         except for perhaps:

            combine         : the addition of a 'combine' block
            -dsets_me_echo  : specify ME data, per echo
            -dsets_me_run   : specify ME data, per run (alternative to _echo)
            -echo_times     : specify echo times (if needed)
            -combine_method : specify method to combine echoes (if any)

         An afni_proc.py command might be updated to include something like:
            
        --------------------------
        last mod date : 2018.02.27
        keywords      : ME, rest
        --------------------------

        afni_proc.py                                                         \
            -blocks          tshift align tlrc volreg mask combine blur      \
                             scale regress                                   \
            -dsets_me_echo   epi_run*_echo_01.nii                            \
            -dsets_me_echo   epi_run*_echo_02.nii                            \
            -dsets_me_echo   epi_run*_echo_03.nii                            \
            -echo_times      15 30.5 41                                      \
            -mask_epi_anat   yes                                             \
            -combine_method  OC
 

        Example 12a. Multi-echo data processing - very simple. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper)
              (              prefer: see Example 13)

         Keep it simple and just focus on the basic ME options, plus a few
         for controlling registration.

         o This example uses 3 echoes of data across just 1 run.
            - so use a single -dsets_me_run option to input EPI datasets
         o Echo 2 is used to drive registration for all echoes.
            - That is the default, but it is good to be explicit.
         o The echo times are not needed, as the echoes are never combined.
         o The echo are never combined (in this example), so that there
           are always 3 echoes, even until the end.
            - Note that the 'regress' block is not valid for multiple echoes.
            
        --------------------------
        last mod date : 2018.02.27
        keywords      : ME, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                FT.12a.ME                                \
            -blocks                 tshift align tlrc volreg mask blur       \
            -copy_anat              FT_anat+orig                             \
            -dsets_me_run           epi_run1_echo*.nii                       \
            -reg_echo               2                                        \
            -tcat_remove_first_trs  2                                        \
            -volreg_align_to        MIN_OUTLIER                              \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp
 

        Example 12b. Multi-echo data processing - OC resting state. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper)
              (              prefer: see Example 13)

         Still keep this simple, mostly focusing on ME options, plus standard
         ones for resting state.

         o This example uses 3 echoes of data across just 1 run.
            - so use a single -dsets_me_run option to input EPI datasets
         o Echo 2 is used to drive registration for all echoes.
            - That is the default, but it is good to be explicit.
         o The echoes are combined via the 'combine' block.
         o So -echo_times is used to provided them.
            
        --------------------------
        last mod date : 2020.01.08
        keywords      : ME, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT.12a.ME                              \
            -blocks                   tshift align tlrc volreg mask combine  \
                                      blur scale regress                     \
            -copy_anat                FT_anat+orig                           \
            -dsets_me_run             epi_run1_echo*.nii                     \
            -echo_times               15 30.5 41                             \
            -reg_echo                 2                                      \
            -tcat_remove_first_trs    2                                      \
            -align_opts_aea           -cost lpc+ZZ                           \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -combine_method           OC                                     \
            -blur_size                4                                      \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits
 

        Example 12c. Multi-echo data processing - ME-ICA resting state. ~2~

              (recommended?  no, not intended for a complete analysis)
              (              many missing preferences, e.g. @SSwarper)
              (              prefer: see Example 13)

         As above, but run tedana.py for MEICA denoising.

         o Since tedana.py will mask the data, it may be preferable to
           blur only within that mask (-blur_in_mask yes).
         o A task analysis using tedana might look much the same,
           but with the extra -regress options for the tasks.
            
        --------------------------
        last mod date : 2020.01.08
        keywords      : ME, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT.12a.ME                              \
            -blocks                   tshift align tlrc volreg mask combine  \
                                      blur scale regress                     \
            -copy_anat                FT_anat+orig                           \
            -dsets_me_run             epi_run1_echo*.nii                     \
            -echo_times               15 30.5 41                             \
            -reg_echo                 2                                      \
            -tcat_remove_first_trs    2                                      \
            -align_opts_aea           -cost lpc+ZZ                           \
            -tlrc_base                MNI152_2009_template.nii.gz            \
            -tlrc_NL_warp                                                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -combine_method           tedana                                 \
            -blur_size                4                                      \
            -blur_in_mask             yes                                    \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits

         Consider an alternative combine method, 'tedana_OC_tedort'.
           

        Example 13. Complicated ME, surface-based resting state example. ~2~

              (recommended?  yes, reasonable for a complete analysis)

         Key aspects of this example:

            - multi-echo data, using "optimally combined" echoes
            - resting state analysis (without band passing)
            - surface analysis
            - blip up/blip down distortion correction
            - slice-wise regression of physiological parameters (RETROICOR)
            - ventricle principal component regression (3 PCs)
            - EPI volreg to per-run MIN_OUTLIER, with across-runs allineate
            - QC: @radial_correlate on tcat and volreg block results
            - QC: pythonic html report

            * since this is a surface-based example, the are no tlrc options

         Minor aspects:

            - a FWHM=6mm blur is applied, since blur on surface is TO is size

         Note: lacking good sample data for this example, it is simply faked
               for demonstration (echoes are identical, fake ricor parameters
               are not part of this data tree).
            
        --------------------------
        last mod date : 2019.09.06
        keywords      : complete, ME, physio, rest, surface
        --------------------------

        afni_proc.py                                                         \
            -subj_id                   FT.complicated                        \
            -blocks                    despike ricor tshift align volreg     \
                                       mask combine surf blur scale regress  \
            -radial_correlate_blocks   tcat volreg                           \
            -blip_forward_dset         'FT/FT_epi_r1+orig.HEAD[0]'           \
            -blip_reverse_dset         'FT/FT_epi_r1+orig.HEAD[0]'           \
            -copy_anat                 FT/FT_anat+orig                       \
            -anat_follower_ROI         FSvent epi FT/SUMA/FT_vent.nii        \
            -anat_follower_erode       FSvent                                \
            -regress_ROI_PC            FSvent 3                              \
            -regress_ROI_PC_per_run    FSvent                                \
            -regress_make_corr_vols    FSvent                                \
            -dsets_me_echo             FT/FT_epi_r?+orig.HEAD                \
            -dsets_me_echo             FT/FT_epi_r?+orig.HEAD                \
            -dsets_me_echo             FT/FT_epi_r?+orig.HEAD                \
            -echo_times                11 22.72 34.44                        \
            -combine_method            OC                                    \
            -tcat_remove_first_trs     2                                     \
            -tshift_interp             -wsinc9                               \
            -mask_epi_anat             yes                                   \
            -ricor_regs_nfirst         2                                     \
            -ricor_regs                FT/fake.slibase.FT.r?.1D              \
            -ricor_regress_method      per-run                               \
            -align_unifize_epi         local                                 \
            -align_opts_aea            -cost lpc+ZZ                          \
                                       -giant_move                           \
            -volreg_align_to           MIN_OUTLIER                           \
            -volreg_align_e2a                                                \
            -volreg_post_vr_allin      yes                                   \
            -volreg_pvra_base_index    MIN_OUTLIER                           \
            -volreg_warp_final_interp  wsinc5                                \
            -surf_anat                 FT/SUMA/FT_SurfVol.nii                \
            -surf_spec                 FT/SUMA/std.141.FT_?h.spec            \
            -blur_size                 6                                     \
            -regress_censor_motion     0.2                                   \
            -regress_censor_outliers   0.05                                  \
            -regress_motion_per_run                                          \
            -regress_apply_mot_types   demean deriv                          \
            -html_review_style         pythonic
 

        AP class 3. s03.ap.surface - basic surface analysis ~2~

              (recommended?  yes, reasonable for a complete analysis)
                             (though it is a very simple example)

           This is the surface analysis run during an AFNI bootcamp.
            
        --------------------------
        last mod date : 2022.11.23
        keywords      : complete, surface, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                 FT.surf                                 \
            -blocks                  tshift align volreg surf blur scale     \
                                     regress                                 \
            -copy_anat               FT/FT_anat+orig                         \
            -dsets                   FT/FT_epi_r?+orig.HEAD                  \
            -surf_anat               FT/SUMA/FT_SurfVol.nii                  \
            -surf_spec               FT/SUMA/std.60.FT_?h.spec               \
            -tcat_remove_first_trs   2                                       \
            -align_unifize_epi       local                                   \
            -align_opts_aea          -cost lpc+ZZ                            \
                                     -giant_move                             \
                                     -check_flip                             \
            -volreg_align_to         MIN_OUTLIER                             \
            -volreg_align_e2a                                                \
            -blur_size               6                                       \
            -regress_stim_times      FT/AV1_vis.txt FT/AV2_aud.txt           \
            -regress_stim_labels     vis aud                                 \
            -regress_basis           'BLOCK(20,1)'                           \
            -regress_motion_per_run                                          \
            -regress_censor_motion   0.3                                     \
            -regress_opts_3dD        -jobs 2                                 \
                                     -gltsym 'SYM: vis -aud'                 \
                                     -glt_label 1 V-A
 

        AP class 5. s05.ap.uber - basic task analysis ~2~

              (recommended?  no, not intended for a complete analysis)
              (              prefer: see Example 6b)

           A basic task analysis with a pair of visual and auditory tasks.

           notable options include :
                - affine registration to the (default) TT_N27+tlrc template
                - censoring based on both motion params and outliers
                - '-regress_compute_fitts' to reduce RAM needs in 3dD
                - mask_epi_anat - intersect full_mask (epi) with mask_anat
                - QC: computing radial correlation volumes at the end
                      of the tcat (initial) and volreg processing blocks
                - QC: include -check_flip left/right consistency check
                - QC: compute sum of ideals, for evaluation
            
        --------------------------
        last mod date : 2022.11.23
        keywords      : task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT                                     \
            -blocks                   tshift align tlrc volreg blur mask     \
                                      scale regress                          \
            -radial_correlate_blocks  tcat volreg                            \
            -copy_anat                FT/FT_anat+orig                        \
            -dsets                    FT/FT_epi_r1+orig.HEAD                 \
                                      FT/FT_epi_r2+orig.HEAD                 \
                                      FT/FT_epi_r3+orig.HEAD                 \
            -tcat_remove_first_trs    2                                      \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -blur_size                4.0                                    \
            -mask_epi_anat            yes                                    \
            -regress_stim_times       FT/AV1_vis.txt FT/AV2_aud.txt          \
            -regress_stim_labels      vis aud                                \
            -regress_basis            'BLOCK(20,1)'                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_motion_per_run                                          \
            -regress_opts_3dD         -jobs 2                                \
                                      -gltsym 'SYM: vis -aud'                \
                                      -glt_label 1 V-A                       \
                                      -gltsym 'SYM: 0.5*vis +0.5*aud'        \
                                      -glt_label 2 mean.VA                   \
            -regress_compute_fitts                                           \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     no                                     \
            -execute
 

        AP demo 1a. for QC, ap_run_simple_rest.tcsh with EPI and anat ~2~

              (recommended?  yes, for quick quality control)

         This example was generated by running ap_run_simple_rest.tcsh,
         providing a single subject anat and (3 runs of) EPI.  It could
         be generated (and run) using the following:

            cd AFNI_data6/FT_analysis/FT
            ap_run_simple_rest.tcsh -subjid FT -run_proc \
              -anat FT_anat+orig -epi FT_epi_r*.HEAD

         This is highly recommended as a tool for quick quality control to be
         run on all EPI data right out of the scanner.  It is fine to run on
         task data, but without worrying about the actual task regression.

            
        --------------------------
        last mod date : 2024.02.20
        keywords      : rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT                                     \
            -blocks                   tshift align tlrc volreg mask blur     \
                                      scale regress                          \
            -radial_correlate_blocks  tcat volreg regress                    \
            -copy_anat                FT_anat+orig                           \
            -dsets                    FT/FT_epi_r1+orig.HEAD                 \
                                      FT/FT_epi_r2+orig.HEAD                 \
                                      FT/FT_epi_r3+orig.HEAD                 \
            -tcat_remove_first_trs    2                                      \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_compute_tsnr      yes                                    \
            -mask_epi_anat            yes                                    \
            -blur_size                6                                      \
            -regress_censor_motion    0.25                                   \
            -regress_censor_outliers  0.05                                   \
            -regress_motion_per_run                                          \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -html_review_style        pythonic
 

        AP demo 1b. for QC, ap_run_simple_rest.tcsh with no anat ~2~

              (recommended?  yes, for quick quality control of EPI)

         This example was generated by running ap_run_simple_rest.tcsh,
         providing only 3 runs of EPI data.  It could be generated (and run)
         using the following:

            cd AFNI_data6/FT_analysis/FT
            ap_run_simple_rest.tcsh -subjid FT -run_proc -epi FT_epi_r*.HEAD

         No anatomical volume is included, excluding many options from
         example simple_rest_QC.

            
        --------------------------
        last mod date : 2022.11.23
        keywords      : rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  FT                                     \
            -script                   proc.FT                                \
            -out_dir                  FT.results                             \
            -blocks                   tshift volreg mask blur scale regress  \
            -radial_correlate_blocks  tcat volreg                            \
            -dsets                    FT/FT_epi_r1+orig.HEAD                 \
                                      FT/FT_epi_r2+orig.HEAD                 \
                                      FT/FT_epi_r3+orig.HEAD                 \
            -tcat_remove_first_trs    2                                      \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_compute_tsnr      yes                                    \
            -blur_size                6                                      \
            -regress_censor_motion    0.25                                   \
            -regress_censor_outliers  0.05                                   \
            -regress_motion_per_run                                          \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -html_review_style        pythonic
 

        AP demo 2a. do_20_ap_se.tcsh - one way to process rest data ~2~

              (recommended?  somewhat, includes tissue-based regression)

         This example is part of the APMULTI_Demo1_rest tree, installable by
         running :

            @Install_APMULTI_Demo1_rest

         This is a sample rest processing command, including:

            - despike block for high motion subjects

            - QC options:
                -radial_correlate_blocks, (-align_opts_aea) -check_flip
                -volreg_compute_tsnr, -regress_make_corr_vols,
                -html_review_style, -anat_follower_ROI (some are for QC)

            - non-linear template alignment (precomputed warp is provided)

            - noise removal of:
                - motion and derivatives, per run
                - ventricle principal components (top 3 per run)
                - fast ANATICOR
                - censoring for both motion and outliers

         * input dataset names have been shortened to protect the margins

            
        --------------------------
        last mod date : 2023.04.19
        keywords      : complete, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  sub-005                                \
            -blocks                   despike tshift align tlrc volreg mask  \
                                      blur scale regress                     \
            -radial_correlate_blocks  tcat volreg                            \
            -copy_anat                sswarper/anatSS.sub-005.nii            \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat                      \
                                      sswarper/anatU.sub-005.nii             \
            -anat_follower_ROI        aaseg anat                             \
                                      SUMA/aparc.a2009s+aseg_REN_all.nii.gz  \
            -anat_follower_ROI        aeseg epi                              \
                                      SUMA/aparc.a2009s+aseg_REN_all.nii.gz  \
            -anat_follower_ROI        FSvent epi SUMA/fs_ap_latvent.nii.gz   \
            -anat_follower_ROI        FSWe epi SUMA/fs_ap_wm.nii.gz          \
            -anat_follower_erode      FSvent FSWe                            \
            -dsets                    func/sub-005_rest_echo-2_bold.nii.gz   \
            -tcat_remove_first_trs    4                                      \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     sswarper/anatQQ.sub-005.nii            \
                                      sswarper/anatQQ.sub-005.aff12.1D       \
                                      sswarper/anatQQ.sub-005_WARP.nii       \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_warp_dxyz         3                                      \
            -volreg_compute_tsnr      yes                                    \
            -blur_size                5                                      \
            -mask_epi_anat            yes                                    \
            -regress_motion_per_run                                          \
            -regress_ROI_PC           FSvent 3                               \
            -regress_ROI_PC_per_run   FSvent                                 \
            -regress_make_corr_vols   aeseg FSvent                           \
            -regress_anaticor_fast                                           \
            -regress_anaticor_label   FSWe                                   \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -html_review_style        pythonic
 

        AP demo 2b. do_44_ap_me_bTs.tcsh - ME surface rest with tedana ~2~

              (recommended?  yes)

         This example is based on the APMULTI_Demo1_rest tree, installable by
         running :

            @Install_APMULTI_Demo1_rest

         This is a sample rest processing command, including:

            - reverse phase encoding (blip) distortion correction
              (-blip_forward_dset, -blip_reverse_dset)
            - multi-echo EPI (-dsets_me_run, -echo_times)
            - MEICA-group tedana usage
              (-combine_method m_tedana, -volreg_warp_final_interp wsinc5)

            - surface-based analysis (-surf_anat, -surf_spec)

            - despike block for high motion subjects

            - QC options:
                -radial_correlate_blocks, -align_opts_aea -check_flip,
                -volreg_compute_tsnr, -regress_make_corr_vols,
                -anat_follower anat_w_skull, -anat_follower_ROI (some for QC),
                -html_review_style

            - noise removal of:
                - tedana
                - motion and derivatives, per run
                - censoring for both motion and outliers

         * input dataset names have been shortened to protect the margins

            
        --------------------------
        last mod date : 2024.01.04
        keywords      : complete, blip, ME, rest, surface, tedana
        --------------------------

        afni_proc.py                                                         \
            -subj_id                   sub-005                               \
            -blocks                    despike tshift align volreg mask      \
                                       combine surf blur scale regress       \
            -radial_correlate_blocks   tcat volreg                           \
            -copy_anat                 sswarper/anatSS.sub-005.nii           \
            -anat_has_skull            no                                    \
            -anat_follower             anat_w_skull anat                     \
                                       sswarper/anatU.sub-005.nii            \
            -anat_follower_ROI         aaseg anat                            \
                                       SUMA/aparc.a2009s+aseg_REN_all.nii.gz \
            -anat_follower_ROI         aeseg epi                             \
                                       SUMA/aparc.a2009s+aseg_REN_all.nii.gz \
            -anat_follower_ROI         FSvent epi SUMA/fs_ap_latvent.nii.gz  \
            -anat_follower_ROI         FSWe epi SUMA/fs_ap_wm.nii.gz         \
            -anat_follower_erode       FSvent FSWe                           \
            -surf_anat                 SUMA/sub-005_SurfVol.nii              \
            -surf_spec                 SUMA/std.141.sub-005_lh.spec          \
                                       SUMA/std.141.sub-005_rh.spec          \
            -blip_forward_dset         'func/sub-005_blip-match.nii.gz[0]'   \
            -blip_reverse_dset         'func/sub-005_blip-opp.nii.gz[0]'     \
            -dsets_me_run              func/sub-005_rest_echo-1_bold.nii.gz  \
                                       func/sub-005_rest_echo-2_bold.nii.gz  \
                                       func/sub-005_rest_echo-3_bold.nii.gz  \
            -echo_times                12.5 27.6 42.7                        \
            -combine_method            m_tedana                              \
            -tcat_remove_first_trs     4                                     \
            -tshift_interp             -wsinc9                               \
            -align_unifize_epi         local                                 \
            -align_opts_aea            -cost lpc+ZZ                          \
                                       -giant_move                           \
                                       -check_flip                           \
            -volreg_align_to           MIN_OUTLIER                           \
            -volreg_align_e2a                                                \
            -volreg_warp_final_interp  wsinc5                                \
            -volreg_compute_tsnr       yes                                   \
            -blur_size                 4                                     \
            -mask_epi_anat             yes                                   \
            -regress_motion_per_run                                          \
            -regress_make_corr_vols    aeseg FSvent                          \
            -regress_censor_motion     0.2                                   \
            -regress_censor_outliers   0.05                                  \
            -regress_apply_mot_types   demean deriv                          \
            -html_review_style         pythonic
 

        AP publish 1. pamenc, ds000030.v16 parametric encoding task analysis. ~2~

              (recommended?  yes, reasonable for a complete analysis)

           original analysis was from:
               Gorgolewski KJ, Durnez J and Poldrack RA.
               Preprocessed Consortium for Neuropsychiatric Phenomics dataset.
               F1000Research 2017, 6:1262
               https://doi.org/10.12688/f1000research.11964.2

           downloadable from https://legacy.openfmri.org/dataset/ds000030
            
        --------------------------
        last mod date : 2020.02.10
        keywords      : complete, publish, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  SID                                    \
            -script                   proc.SID                               \
            -scr_overwrite                                                   \
            -blocks                   tshift align tlrc volreg mask blur     \
                                      scale regress                          \
            -copy_anat                anatSS.SID.nii                         \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat anatU.SID.nii        \
            -dsets                    func/SID_task-pamenc_bold.nii.gz       \
            -tcat_remove_first_trs    0                                      \
            -tshift_opts_ts           -tpattern alt+z2                       \
            -radial_correlate         yes                                    \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     anatQQ.SID.nii anatQQ.SID.aff12.1D     \
                                      anatQQ.SID_WARP.nii                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -blur_size                6                                      \
            -blur_in_mask             yes                                    \
            -regress_stim_times       timing/times.CONTROL.txt               \
                                      timing/times.TASK.txt                  \
            -regress_stim_labels      CONTROL TASK                           \
            -regress_stim_types       AM1                                    \
            -regress_basis_multi      dmBLOCK                                \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_compute_fitts                                           \
            -regress_fout             no                                     \
            -regress_opts_3dD         -jobs 8                                \
            -regress_3dD_stop                                                \
            -regress_reml_exec                                               \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     no                                     \
            -html_review_style        pythonic
 

        AP publish 2. NARPS analysis from AFNI. ~2~

              (recommended?  yes, reasonable for a complete analysis)

           An amplitude modulation task analysis.
            
        --------------------------
        last mod date : 2020.02.10
        keywords      : complete, publish, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  sid                                    \
            -script                   proc.sid                               \
            -scr_overwrite                                                   \
            -blocks                   tshift align tlrc volreg mask blur     \
                                      scale regress                          \
            -copy_anat                anatSS.sid.nii                         \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat anatU.sid.nii        \
            -anat_follower_ROI        FS_wm_e epi                            \
                                      SUMA/mask.aseg.wm.e1.nii.gz            \
            -anat_follower_ROI        FS_REN_epi epi                         \
                                      SUMA/aparc+aseg_REN_all.nii.gz         \
            -anat_follower_ROI        FS_REN_anat anat                       \
                                      SUMA/aparc+aseg_REN_all.nii.gz         \
            -anat_follower_erode      FS_wm_e                                \
            -dsets                    func/sid_task-MGT_run-01_bold.nii.gz   \
                                      func/sid_task-MGT_run-02_bold.nii.gz   \
                                      func/sid_task-MGT_run-03_bold.nii.gz   \
                                      func/sid_task-MGT_run-04_bold.nii.gz   \
            -tcat_remove_first_trs    0                                      \
            -tshift_opts_ts           -tpattern alt+z2                       \
            -radial_correlate         yes                                    \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     anatQQ.sid.nii anatQQ.sid.aff12.1D     \
                                      anatQQ.sid_WARP.nii                    \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -mask_epi_anat            yes                                    \
            -blur_size                5                                      \
            -test_stim_files          no                                     \
            -regress_stim_times       timing/times.Resp.txt                  \
                                      timing/times.NoResp.txt                \
            -regress_stim_labels      Resp NoResp                            \
            -regress_stim_types       AM2 AM1                                \
            -regress_basis_multi      dmBLOCK                                \
            -regress_anaticor_fast                                           \
            -regress_anaticor_fwhm    20                                     \
            -regress_anaticor_label   FS_wm_e                                \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_compute_fitts                                           \
            -regress_opts_3dD         -jobs 8                                \
                                      -gltsym 'SYM: Resp[1] -Resp[2]'        \
                                      -glt_label 1 gain-loss                 \
                                      -GOFORIT 10                            \
            -regress_opts_reml        -GOFORIT                               \
            -regress_3dD_stop                                                \
            -regress_reml_exec                                               \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -regress_make_corr_vols   FS_wm_e                                \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     no                                     \
            -html_review_style        pythonic
 

        AP publish 3a. do_21_ap_ex1_align.tcsh - only perform alignment steps. ~2~

              (recommended?  somewhat, for alignment only)

         This example is based on the APMULTI_Demo1_rest tree, but will come
         with a new demo package.  Probably.  Maybe.

         This is a full analysis, including:

            - reverse phase encoding (blip) distortion correction
              (-blip_forward_dset, -blip_reverse_dset)
            - EPI motion registration (to MIN_OUTLIER)
            - EPI to anatomical registration
            - non-linear anatomical to MNI template registration
              (precomputed affine+non-linear warp is provided)
            * the regress block is included only for QC

            - QC options:
                -anat_follower (with skull), (-align_opts_aea) -check_flip

         * input dataset names have been shortened to protect the margins

            
        --------------------------
        last mod date : 2024.01.26
        keywords      : partial, publish, align
        --------------------------

        afni_proc.py                                                         \
            -subj_id                sub-005.eg1                              \
            -blocks                 align tlrc volreg regress                \
            -copy_anat              sswarper/anatSS.sub-005.nii              \
            -anat_has_skull         no                                       \
            -anat_follower          anat_w_skull anat                        \
                                    sswarper/anatU.sub-005.nii               \
            -dsets                  func/sub-005_rest_echo-2_bold.nii.gz     \
            -blip_forward_dset      'func/sub-005_blip-match.nii.gz[0]'      \
            -blip_reverse_dset      'func/sub-005_blip-opp.nii.gz[0]'        \
            -tcat_remove_first_trs  4                                        \
            -align_unifize_epi      local                                    \
            -align_opts_aea         -cost lpc+ZZ                             \
                                    -giant_move                              \
                                    -check_flip                              \
            -tlrc_base              MNI152_2009_template_SSW.nii.gz          \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets   sswarper/anatQQ.sub-005.nii              \
                                    sswarper/anatQQ.sub-005.aff12.1D         \
                                    sswarper/anatQQ.sub-005_WARP.nii         \
            -volreg_align_to        MIN_OUTLIER                              \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_warp_dxyz       3
 

        AP publish 3b. do_22_ap_ex2_task.tcsh - pamenc task analysis. ~2~

              (recommended?  yes, for a volumetric task analysis)

         This example is based on the AFNI_demos/AFNI_pamenc data.

         This is a full analysis, including:
            - slice time correction (alt+z2 timing pattern)
            - EPI registration to MIN_OUTLIER vr_base volume
            - EPI/anat alignment, with -align_unifize_epi local
            - NL warp to MNI152_2009 template, as computed by @SSwarper
            - all registration transformations are concatenated
            - computing an EPI mask intersected with the anatomical mask
              for blurring and QC (-mask_epi_anat)
            - applying a 6 mm FWHM Gaussian blur, restricted to the EPI mask
            - voxelwise scaling to percent signal change
            - linear regression of task events using duration modulation with
              the BLOCK basis function (dmUBLOCK(-1)), where the ideal response
              height is unit for a 1 s event
            - censoring time points where motion exceeds 0.3 mm or the outlier
              fraction exceeds 5%
            - regression is performed by 3dREMLfit, accounting for voxelwise
              temporal autocorrelation in the noise
            - estimate data blur is from the regression residuals using
              the mixed-model ACF function

            - QC options:
                -anat_follower (with skull), (-align_opts_aea) -check_flip,
                -radial_correlate_blocks, -volreg_compute_tsnr,
                -regress_make_ideal_sum, -html_review_style

         * input dataset names have been shortened

            
        --------------------------
        last mod date : 2024.02.20
        keywords      : complete, publish, task
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  sub-10506.ex2                          \
            -blocks                   tshift align tlrc volreg mask blur     \
                                      scale regress                          \
            -copy_anat                ssw/anatSS.sub-10506.nii               \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat                      \
                                      anat/sub-10506_T1w.nii.gz              \
            -dsets                    func/sub-10506_pamenc_bold.nii.gz      \
            -tcat_remove_first_trs    0                                      \
            -tshift_opts_ts           -tpattern alt+z2                       \
            -radial_correlate_blocks  tcat volreg regress                    \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -giant_move -cost lpc+ZZ               \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     ssw/anatQQ.sub-10506.nii               \
                                      ssw/anatQQ.sub-10506.aff12.1D          \
                                      ssw/anatQQ.sub-10506_WARP.nii          \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_warp_dxyz         3.0                                    \
            -volreg_compute_tsnr      yes                                    \
            -mask_epi_anat            yes                                    \
            -blur_size                6                                      \
            -blur_in_mask             yes                                    \
            -regress_stim_times       timing/times.CONTROL.txt               \
                                      timing/times.TASK.txt                  \
            -regress_stim_labels      CONTROL TASK                           \
            -regress_stim_types       AM1                                    \
            -regress_basis_multi      'dmUBLOCK(-1)'                         \
            -regress_motion_per_run                                          \
            -regress_censor_motion    0.3                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_compute_fitts                                           \
            -regress_fout             no                                     \
            -regress_opts_3dD         -jobs 8                                \
                                      -gltsym 'SYM: TASK -CONTROL'           \
                                      -glt_label 1 T-C                       \
                                      -gltsym 'SYM: 0.5*TASK +0.5*CONTROL'   \
                                      -glt_label 2 meanTC                    \
            -regress_3dD_stop                                                \
            -regress_reml_exec                                               \
            -regress_make_ideal_sum   sum_ideal.1D                           \
            -regress_est_blur_errts                                          \
            -regress_run_clustsim     no                                     \
            -html_review_style        pythonic
 

        AP publish 3c. do_23_ap_ex3_vol.tcsh - rest analysis. ~2~

              (recommended?  yes, an example of resting state analysis)

         This example is based on the APMULTI_Demo1_rest tree, to perform a
         resting state analysis with a single echo time series.

         This is a sample alignment processing command, including:
            - physio regression, slicewise, before any temporal or volumetric
              alterations (and per-run, though there is only 1 run here)
            - slice timing correction (notably after physio regression)
            - EPI registration to MIN_OUTLIER vr_base volume
            - EPI/anat alignment, with -align_unifize_epi local
            - NL warp to MNI152_2009 template, as computed by @SSwarper
            - apply 5 mm FWHM Gaussian blur, approx 1.5*voxel size
            - all registration transformations are concatenated
            - voxelwise scaling to percent signal change
            - regression (projection) of:
                - per run motion and first differences
                - first 3 principle components from volreg ventricles
                  (per run, though only 1 run here)
                - censor motion exceeding 0.2 ~mm from enorm time series,
                  or outliers exceeding 5% of brain 
            - estimate data blur is from the regression residuals and the
              regression input (separately) using the mixed-model ACF function

            - QC options:
                -anat_follower (with skull), -anat_follower_ROI (FS GM mask),
                -radial_correlate_blocks, (-align_opts_aea) -check_flip,
                -volreg_compute_tsnr, -regress_make_corr_vols,
                -html_review_style

         * input dataset names have been shortened to protect the margins

            
        --------------------------
        last mod date : 2024.03.08
        keywords      : complete, publish, physio, rest
        --------------------------

        afni_proc.py                                                         \
            -subj_id                  sub-005.eg3                            \
            -blocks                   ricor tshift align tlrc volreg mask    \
                                      blur scale regress                     \
            -radial_correlate_blocks  tcat volreg regress                    \
            -copy_anat                ssw/anatSS.sub-005.nii                 \
            -anat_has_skull           no                                     \
            -anat_follower            anat_w_skull anat                      \
                                      ssw/anatU.sub-005.nii                  \
            -anat_follower_ROI        aagm09 anat                            \
                                      SUMA/aparc.a2009s+aseg_REN_gmrois.nii.gz \
            -anat_follower_ROI        aegm09 epi                             \
                                      SUMA/aparc.a2009s+aseg_REN_gmrois.nii.gz \
            -dsets                    func/sub-005_rest_echo-2_bold.nii.gz   \
            -tcat_remove_first_trs    4                                      \
            -ricor_regs               physio/sub-005_rest_physio.slibase.1D  \
            -ricor_regs_nfirst        4                                      \
            -ricor_regress_method     per-run                                \
            -align_unifize_epi        local                                  \
            -align_opts_aea           -cost lpc+ZZ                           \
                                      -giant_move                            \
                                      -check_flip                            \
            -tlrc_base                MNI152_2009_template_SSW.nii.gz        \
            -tlrc_NL_warp                                                    \
            -tlrc_NL_warped_dsets     ssw/anatQQ.sub-005.nii                 \
                                      ssw/anatQQ.sub-005.aff12.1D            \
                                      ssw/anatQQ.sub-005_WARP.nii            \
            -volreg_align_to          MIN_OUTLIER                            \
            -volreg_align_e2a                                                \
            -volreg_tlrc_warp                                                \
            -volreg_warp_dxyz         3                                      \
            -volreg_compute_tsnr      yes                                    \
            -mask_epi_anat            yes                                    \
            -blur_size                5                                      \
            -regress_motion_per_run                                          \
            -regress_make_corr_vols   aegm09                                 \
            -regress_censor_motion    0.2                                    \
            -regress_censor_outliers  0.05                                   \
            -regress_apply_mot_types  demean deriv                           \
            -regress_est_blur_epits                                          \
            -regress_est_blur_errts                                          \
            -html_review_style        pythonic
 

        AP publish 3d. do_24_ap_ex4_mesurf.tcsh - multi-echo surface-based analysis. ~2~

              (recommended?  yes)

         This example is based on the APMULTI_Demo1_rest tree, to perform a
         resting state analysis on the surface with multi-echo data.

         This is a sample alignment processing command, including:
            - slice timing correction (using wsinc9 interpolation)
            - distortion correction using reverse blip phase encoding
            - EPI registration to MIN_OUTLIER vr_base volume
            - EPI/anat alignment, with -align_unifize_epi local
            - all registration transformations are concatenated, and
              based on echo 2 (as we did not specify), but applied to all
              echoes, and resampled using a wsinc9 interpolant
            - compute a mask dataset to give to tedana (-mask_epi_anat)
              (having tedana do the projection results in masked EPI data)
            - echos are combined and then "cleaned" by tedana
            - the EPI time series are then  projected onto the surface
              (a previously computed set of surfaces, registered to the
              current anat, making a new SurfVol_Alnd_Exp anat dset)
            - (light) blurring _to_ of FWHM of 4 mm is applied on the surface
            - nodewise scaling to percent signal change
            - (light, since tedana) regression (projection) of:
                - per run motion and first differences
                - censor motion exceeding 0.2 ~mm from enorm time series,
                  or outliers exceeding 5% of brain 

            - QC options:
                -anat_follower (with skull), -anat_follower_ROI (FS ROIs),
                -radial_correlate_blocks, (-align_opts_aea) -check_flip,
                -volreg_compute_tsnr, -regress_make_corr_vols,
                -html_review_style

         * input dataset names have been shortened to protect the margins

            
        --------------------------
        last mod date : 2024.01.30
        keywords      : complete, blip, ME, publish, rest, surface, tedana
        --------------------------

        afni_proc.py                                                         \
            -subj_id                   sub-005.eg4                           \
            -blocks                    tshift align volreg mask combine surf \
                                       blur scale regress                    \
            -radial_correlate_blocks   tcat volreg                           \
            -copy_anat                 ssw/anatSS.sub-005.nii                \
            -anat_has_skull            no                                    \
            -anat_follower             anat_w_skull anat                     \
                                       ssw/anatU.sub-005.nii                 \
            -anat_follower_ROI         aaseg anat                            \
                                       SUMA/aparc.a2009s+aseg_REN_all.nii.gz \
            -anat_follower_ROI         aeseg epi                             \
                                       SUMA/aparc.a2009s+aseg_REN_all.nii.gz \
            -anat_follower_ROI         FSvent epi SUMA/fs_ap_latvent.nii.gz  \
            -anat_follower_erode       FSvent                                \
            -surf_anat                 SUMA/sub-005_SurfVol.nii              \
            -surf_spec                 SUMA/std.141.sub-005_lh.spec          \
                                       SUMA/std.141.sub-005_rh.spec          \
            -blip_forward_dset         'func/sub-005_blip-match.nii.gz[0]'   \
            -blip_reverse_dset         'func/sub-005_blip-opp.nii.gz[0]'     \
            -dsets_me_run              func/sub-005_rest_echo-1_bold.nii.gz  \
                                       func/sub-005_rest_echo-2_bold.nii.gz  \
                                       func/sub-005_rest_echo-3_bold.nii.gz  \
            -echo_times                12.5 27.6 42.7                        \
            -combine_method            m_tedana                              \
            -tcat_remove_first_trs     4                                     \
            -tshift_interp             -wsinc9                               \
            -align_unifize_epi         local                                 \
            -align_opts_aea            -cost lpc+ZZ                          \
                                       -giant_move                           \
                                       -check_flip                           \
            -volreg_align_to           MIN_OUTLIER                           \
            -volreg_align_e2a                                                \
            -volreg_warp_final_interp  wsinc5                                \
            -volreg_compute_tsnr       yes                                   \
            -blur_size                 4                                     \
            -mask_epi_anat             yes                                   \
            -regress_motion_per_run                                          \
            -regress_make_corr_vols    aeseg FSvent                          \
            -regress_censor_motion     0.2                                   \
            -regress_censor_outliers   0.05                                  \
            -regress_apply_mot_types   demean deriv                          \
            -html_review_style         pythonic
 


-ask_me EXAMPLES:  ** NOTE: -ask_me is antiquated ** ~2~

            afni_proc.py -ask_me

    Perhaps at some point this will be revived.  It would be useful.
    The -ask_me methods have not been seriously updated since 2006.


==================================================
Many NOTE sections: ~1~
==================================================

--------------------------------------------------
GENERAL ANALYSIS NOTE: ~2~

How might one run a full analysis?  Here are some details to consider.

0. Expect to re-run the full analysis.  This might be to fix a mistake, to
   change applied options or to run with current software, to name a few
   possibilities.  So...

     - keep permanently stored input data separate from computed results
       (one should be able to easily delete the results to start over)
     - keep scripts in yet another location
     - use file naming that is consistent across subjects and groups,
       making it easy to script with

1. Script everything.  One should be able to carry out the full analysis
   just by running the main scripts.

   Learning is best done by typing commands and looking at data, including
   the input to and output from said commands.  But running an analysis for
   publication should not rely on typing complicated commands or pressing
   buttons in a GUI (graphical user interface).

     - it is easy to apply to new subjects
     - the steps can be clear and unambiguous (no magic or black boxes)
     - some scripts can be included with publication
       (e.g. an afni_proc.py command, with the AFNI version)

     - using a GUI relies on consistent button pressing, making it much
       more difficult to *correctly* repeat, or even understand

2. Analyze and perform quality control on new subjects promptly.

     - any problems with the acquisition would (hopefully) be caught early
     - can compare basic quality control measures quickly

3. LOOK AT YOUR DATA.  Quality control is best done by researchers.
   Software should not be simply trusted.

     - afni_proc.py processing scripts write guiding @ss_review_driver
       scripts for *minimal* per-subject quality control (i.e. at a
       minimum, run that for every subject)
     - initial subjects should be scrutinized (beyond @ss_review_driver)

     - concatenate anat_final datasets to look for consistency
     - concatenate final_epi datasets to look for consistency
     - run gen_ss_review_table.py on the out.ss_review*.txt files
       (making a spreadsheet to quickly scan for outlier subjects)

     - many issues can be detected by software, buy those usually just come
       as warnings to the researcher
     - similarly, some issues will NOT be detected by the software
     - for QC, software can assist the researcher, not replace them

     NOTE: Data from external sites should be heavily scrutinized,
           including any from well known public repositories.

4. Consider regular software updates, even as new subjects are acquired.
   This ends up requiring a full re-analysis at the end.

   If it will take a while (one year or more?) to collect data, update the
   software regularly (weekly?  monthly?).  Otherwise, the analysis ends up
   being done with old software.

      - analysis is run with current, rather than old software
      - will help detect changes in the software (good ones or bad ones)
      - at a minimum, more quality control tools tend to show up
      - keep a copy of the prior software version, in case comparisons are
        desired (@update.afni.binaries does keep one prior version)
      - the full analysis should be done with one software version, so once
        all datasets are collected, back up the current analysis and re-run
        the entire thing with the current software
      - keep a snapshot of the software package used for the analysis
      - report the software version in any publication

5. Here is a sample (tcsh) script that might run a basic analysis on
   one or more subjects:

   ======================================================================
   sample analysis script ~3~
   ======================================================================

   #!/bin/tcsh

   # --------------------------------------------------
   # note fixed top-level directories
   set data_root = /main/location/of/all/data

   set input_root = $data_root/scanner_data
   set output_root = $data_root/subject_analysis

   # --------------------------------------------------
   # get a list of subjects, or just use one (consider $argv)
   cd $input root
   set subjects = ( subj* )
   cd -

   # or perhaps just process one subject?
   set subjects = ( subj_017 )


   # --------------------------------------------------
   # process all subjects
   foreach subj_id ( $subjects )

      # --------------------------------------------------
      # note input and output directories
      set subj_indir = $input_root/$subj_id
      set subj_outdir = $output_root/$subj_id

      # --------------------------------------------------
      # if output dir exists, this subject has already been processed
      if ( -d $subj_outdir ) then
         echo "** results dir already exists, skipping subject $subj_id"
         continue
      endif

      # --------------------------------------------------
      # otherwise create the output directory, write an afni_proc.py
      # command to it, and fire it up

      mkdir -p $subj_outdir
      cd $subj_outdir

      # create a run.afni_proc script in this directory
      cat > run.afni_proc << EOF

      # notes:
      #   - consider different named inputs (rather than OutBrick)
      #   - verify how many time points to remove at start (using 5)
      #   - note which template space is preferable (using MNI)
      #   - consider non-linear alignment via -tlrc_NL_warp
      #   - choose blur size (using FWHM = 4 mm)
      #   - choose basis function (using BLOCK(2,1), for example)
      #   - assuming 4 CPUs for linear regression
      #   - afni_proc.py will actually run the proc script (-execute)


      afni_proc.py -subj_id $subj_id                          \
          -blocks tshift align tlrc volreg blur mask regress  \
          -copy_anat $subj_indir/anat+orig                    \
          -dsets                                              \
              $subj_indir/epi_r1+orig                         \
              $subj_indir/epi_r2+orig                         \
              $subj_indir/epi_r3+orig                         \
          -tcat_remove_first_trs 5                            \
          -align_opts_aea -cost lpc+ZZ                        \
          -tlrc_base MNI152_2009_template.nii.gz              \
          -tlrc_NL_warp                                       \
          -volreg_align_to MIN_OUTLIER                        \
          -volreg_align_e2a                                   \
          -volreg_tlrc_warp                                   \
          -blur_size 4.0                                      \
          -regress_motion_per_run                             \
          -regress_censor_motion 0.3                          \
          -regress_reml_exec -regress_3dD_stop                \
          -regress_stim_times                                 \
              $stim_dir/houses.txt                            \
              $stim_dir/faces.txt                             \
              $stim_dir/doughnuts.txt                         \
              $stim_dir/pizza.txt                             \
          -regress_stim_labels                                \
              house face nuts za                              \
          -regress_basis 'BLOCK(2,1)'                         \
          -regress_opts_3dD                                   \
              -jobs 4                                         \
              -gltsym 'SYM: house -face' -glt_label 1 H-F     \
              -gltsym 'SYM: nuts -za'    -glt_label 2 N-Z     \
          -regress_est_blur_errts                             \
          -execute

   EOF
   # EOF terminates the 'cat > run.afni_proc' command, above
   # (it must not be indented in the script)

      # now run the analysis (generate proc and execute)
      tcsh run.afni_proc

   # end loop over subjects
   end

   ======================================================================

--------------------------------------------------
DIRECTORY STRUCTURE NOTE: ~2~

We are working to have a somewhat BIDS-like directory structure.  If our
tools know where to be able to find processed data, many things beyond the
single subject level can be automated.

Starting with a main STUDY (ds000210 in the example) tree, the directory
structure has individual subject input trees at the top level.  Each
subject directory (e.g. sub-001) would contain all of the original data for
that subject, possibly including multiple tasks or resting state data,
anatomical, DWI, etc.  The example includes 1 run of rest, 3 runs of the
cuedSGT task data, and corresponding cuedSGT timing files.

Processed data would then go under a 'derivatives' directory under STUDY
(ds000210), with each sub-directory being a single analysis.  The example
shows a preperatory analysis to do non-linear registration, plus a resting
state analysis and the cuedSGT analysis.

In our case, assuming one is using non-linear registration, the derivatives
directory might contain directories like:

    AFNI_01_SSwarp      - single subject non-linear warp results
                          (these would be used as input to afni_proc.py
                          in any other analyses)

    AFNI_02_task_XXXX   - some main analysis, including single subject
                          (via afni_proc.py?) and possibly group results

    AFNI_03_rest        - maybe a resting state analysis, for example


      So a sample directory tree might look something like:
   
      ds000210 (main study directory)
      |        \                \
      sub-001  sub-002           derivatives
     /                           |            \               \
    --anat                    AFNI_01_SSwarp  AFNI_02_rest    AFNI_03_cuedSGT
         \                    |               |        \
         sub-001_T1w.nii.gz   sub-001         sub-001   sub-002  ...
                               |               |
    --func                    WARP.nii        cmd.afni_proc
         \                                    proc.sub-001
         sub-001_task-rest_run-01.nii.gz      output.proc.sub-001
         sub-001_task-cuedSGT_run-01.nii.gz   sub-001.results
         sub-001_task-cuedSGT_run-02.nii.gz   stim_timing
         sub-001_task-cuedSGT_run-03.nii.gz
         sub-001_task-cuedSGT_run-01_events.tsv
         sub-001_task-cuedSGT_run-02_events.tsv
         sub-001_task-cuedSGT_run-03_events.tsv

--------------------------------------------------
QUALITY CONTROL NOTE: ~2~

Look at the data.

Nothing replaces a living human performing quality control checks by
looking at the data.  And the more a person looks at the data, the better
they get at spotting anomalies.

There are 3 types of QC support generated by afni_proc.py, a static QC
HTML page, scripts to help someone review the data, and individual text
or image files.

    ----------------------------------------------------------------------
    QC_$subj/index.html     - auto-generated web page

       This web page and enclosing QC_$subj directory are automatically
       generated by a sequence of programs:

            apqc_make_tcsh.py
            @ss_review_html
            apqc_make_html.py

       This web page was made to encapsulate the @ss_review_driver results
       in a static image, and will be enhanced separately.

    ----------------------------------------------------------------------
    scripts (the user can run from the results directory):

       @epi_review.FT               - view original (post-SS) EPI data
       @ss_review_basic             - show basic QC measures, in text
                                      (automatically run)
       @ss_review_driver            - minimum recommended QC review
       @ss_review_driver_commands   - same, as pure commands

       @ss_review_html              - generate HTML pages under QC_$subj
                                      (automatically run)

       Notably, the @ss_review_driver script is recommended as the minimum
       QC to perform on every subject.

    ----------------------------------------------------------------------
    other files or datasets:   (* shown or reviewed by @ss_review_driver)

    *  3dDeconvolve.err

          This contains any warnings (or errors) from 3dDeconvolve.  This
          will be created even if 3dREMLfit is run.

    *  anat_final.$subj

          This AFNI dataset should be registered with the final stats
          (including final_epi_vr_base) and with any applied template.
          There is also a version with the skull, anat_w_skull_warped.

    *  blur_est.$subj.1D

          This (text) file has the mixed-model ACF (and possibly the FWHM)
          parameter estimates of the blur.

       Classes

          If 3dSeg is run for anatomical segmentation, this AFNI dataset
          contains the results, a set of masks per tissue class.  The
          white matter mask from this might be used for ANATICOR, for
          example.

       corr_brain

          This AFNI dataset shows the correlation of every voxel with the
          global signal (average time series over brain mask).

          One can request other corr_* datasets, based on any tissue or ROI
          mask.  See -regress_make_corr_vols for details.

    *  dfile_rall.1D (and efile.r??.1D)

          This contains the 6 estimated motion parameters across all runs.
          These parameters are generally used as regressors of no interest,
          hopefully per run.  They are also used to generate the enorm time
          series, which is then used for censoring.

       files_ACF

          This directory contains ACF values at different radii per run.
          One can plot them using something like:

            set af = files_ACF/out.3dFWHMx.ACF.errts.r01.1D
            1dplot -one -x $af'[0]' $af'[1,2,3]'

    *  final_epi_vr_base

          This dataset is of the EPI volume registration base (used by
          3dvolreg), warped to the final space.  It should be in alignment
          with the anat_final dataset (and the template).

       fitts.$subj

          This dataset contains the model fit to the time series data.
          One can view these time series together in afni using the
          Dataset #N plugin.

       full_mask.$subj

          This dataset is a brain mask based on the EPI data, generated
          by 3dAutomask.  Though the default is to apply it as part of the
          main regression, it is used for computations like ACF and TSNR.

       ideal_*.1D

          These time series text files are the ideal regressors of
          interest, if appropriate to calculate.

       mat.basewarp.aff12.1D

          This is used to create the final_epi_vr_base dataset.

          Assuming no non-linear registration (including distortion
          correction), then this matrix holds the combined affine
          transformation of the EPI to anat and to standard space,
          as applied to the volume registration base (it does not contain
          motion correction transformations).

          Time series registration matrices that include motion correction
          are in mat.r*.warp.aff12.1D (i.e. one file per run).

          In the case of non-linear registration, there is no single file
          representing the combined transformation, as it is computed just
          to apply the transformation by 3dNwarpApply.  This command can be
          found in the proc script or as the last HISTORY entry seen from
          the output of "3dinfo final_epi_vr_base".

    *  motion_${subj}_enorm.1D

          This time series text file is the L2 (Euclidean) norm of the
          first (backward) differences of the motion parameters.  The
          values represent time point to time point estimated motion, and
          they are used for censoring.  Values are zero at the beginning of
          each run (motion is not computed across runs).

          A high average of these numbers, particularly after the numbers
          themselves are censored, is justification for dropping a subject.
          This average is reported by the @ss_review scripts.

       motion_${subj}_censor.1D

          This is a binary 0/1 time series (matching enorm, say), that
          distinguishes time points which would be censored (0) from those
          which would not (1).  It is based on the enorm time series and
          the -regress_censor_motion limit, with a default to censor in
          pairs of time points.  There may be a combined censor file, if
          outlier censoring is done (or if a user censor file is input).

       motion_demean.1D

          This is the same as dfile_rall.1D, the motion parameters as
          estimated by 3dvolreg, except the the mean per run has been
          removed.

       motion_deriv.1D

          This contains the first (backward) differences from either
          motion_demean.1D or dfile_rall.1D.  Values are zero at the start
          of each run.

       out.allcostX.txt

          This holds anat/EPI registration costs for all cost functions.
          It might be informational to evaluate alignment across subjects
          and cost functions.

    *  out.cormat_warn.txt

          This contains warnings about a high correlation between any pair
          of regressors in the main regression matrix, including baseline
          terms.

    *  out.gcor.1D

          This contains the global correlation, the average correlation
          between every pair of voxels in the residual time series dataset.
          This single value is reported by the @ss_review scripts.

       out.mask_ae_dice.txt

          This contains the Dice coefficient, evaluating the overlap
          between the anatomical and EPI brain masks.

       out.mask_ae_overlap.txt

          This contains general output from 3dOverlap, for evaluating the
          overlap between the anatomical and EPI brain masks.

       out.mask_at_dice.txt

          This contains the Dice coefficient evaluating the overlap
          between the anatomical and template brain masks.

    *  out.pre_ss_warn.txt

          This contains warnings about time point #0 in any run where it
          might be a pre-steady state time point, based on outliers.

    *  out.ss_review.txt

          This is the text output from @ss_review_basic.  Aside from being
          shown by the @ss_review scripts, it is useful for being compiled
          across subjects via gen_ss_review_table.py.

    *  outcount_rall.1D (and outcount.r??.1D)

          This is a time series of the fraction of the brain that is an
          outlier.  It can be used for censoring.

    *  sum_ideal.1D

          As suggested, this time series is the sum of all non-baseline
          regressors.  It is generated from X.nocensor.xmat.1D if censoring
          is done, and from X.xmat.1D otherwise.  This might help one find
          mistakes in stimulus timing, for example.

    *  TSNR_$subj

          This AFNI dataset contains the voxelwise TSNR after regression.
          The brainwise average is shown in @ss_review_basic.

      X.xmat.1D

          This is the complete regression matrix, created by 3dDeconvolve.
          One can view it using 1dplot.  It contains all regressors except
          for any voxelwise ones (e.g. for ANATICOR).

      X.nocensor.xmat.1D

          This is the same as X.xmat.1D, except the nothing is censored,
          so all time points are present.

    * X.stim.xmat.1D

          This (text) file has the non-baseline regressors (so presumably
          of interest), created by 3dDeconvolve.

--------------------------------------------------
RESTING STATE NOTE: ~2~

It is preferable to process resting state data using physio recordings
(for typical single-echo EPI data).  Without such recordings, bandpassing
is currently considered as the standard in the field of FMRI (though that
is finally starting to change).  Multi-echo acquisitions offer other
possibilities.

Comment on bandpassing:

    Bandpassing does not seem like a great method.

    Bandpassing is the norm right now.  However most TRs may be too long
    for this process to be able to remove the desired components of no
    interest.  On the flip side, if the TRs are short, the vast majority
    of the degrees of freedom are sacrificed just to do it.  Perhaps
    bandpassing will eventually go away, but it is the norm right now.

    Also, there is a danger with bandpassing and censoring in that subjects
    with a lot of motion may run out of degrees of freedom (for baseline,
    censoring, bandpassing and removal of other signals of no interest).
    Many papers have been published where a lot of censoring was done,
    many regressors of no interest were projected out, and there was a
    separate bandpass operation.  It is likely that many subjects should
    have ended up with negative degrees of freedom (were bandpassing
    implemented correctly), making the resulting signals useless (or worse,
    misleading garbage).  But without keeping track of it, researchers may
    not even know.

Bandpassing and degrees of freedom:

    Bandpassing between 0.01 and 0.1 means, from just the lowpass side,
    throwing away frequencies above 0.1.  So the higher the frequency of
    collected data (i.e. the smaller the TR), the higher the fraction of
    DoF will be thrown away.

    For example, if TR = 2s, then the Nyquist frequency (the highest
    frequency detectable in the data) is 1/(2*2) = 0.25 Hz.  That is to
    say, one could only detect something going up and down at a cycle rate
    of once every 4 seconds (twice the TR).

    So for TR = 2s, approximately 40% of the DoF are kept (0.1/0.25) and
    60% are lost (frequencies from 0.1 to 0.25) due to bandpassing.

    To generalize, Nyquist = 1/(2*TR), so the fraction of DoF kept is

        fraction kept = 0.1/Nyquist = 0.1/(1/(2*TR)) = 0.1*2*TR = 0.2*TR

    For example,

        at TR = 2 s,   0.4  of DoF are kept (60% are lost)
        at TR = 1 s,   0.2  of DoF are kept (80% are lost)
        at TR = 0.5 s, 0.1  of DoF are kept (90% are lost)
        at TR = 0.1 s, 0.02 of DoF are kept (98% are lost)

    Consider also:

        Shirer WR, Jiang H, Price CM, Ng B, Greicius MD
        Optimization of rs-fMRI pre-processing for enhanced signal-noise
            separation, test-retest reliability, and group discrimination
        Neuroimage. 2015 Aug 15;117:67-79.

        Gohel SR, Biswal BB
        Functional integration between brain regions at rest occurs in
            multiple-frequency bands
        Brain connectivity. 2015 Feb 1;5(1):23-34.

        Caballero-Gaudes C, Reynolds RC
        Methods for cleaning the BOLD fMRI signal
        Neuroimage. 2017 Jul 1;154:128-49

Application of bandpassing in afni_proc.py:

    In afni_proc.py, this is all done in a single regression model (removal
    of noise and baseline signals, bandpassing and censoring).  If some
    subject were to lose too many TRs due to censoring, this step would
    fail, as it should.

    There is an additional option of using simulated motion time series
    in the regression model, which should be more effective than higher
    order motion parameters, say.  This is done via @simulate_motion.

There are 3 main steps (generate ricor regs, pre-process, group analysis):

    step 0: If physio recordings were made, generate slice-based regressors
            using RetroTS.py.  Such regressors can be used by afni_proc.py
            via the 'ricor' processing block.

            RetroTS.m is Ziad Saad's MATLAB routine to convert the 2 time
            series into 13 slice-based regressors.  RetroTS.m requires the
            signal processing toolkit for MATLAB.

          * RetroTS.py is a conversion of RetroTS.m to python by J Zosky.
            It depends on scipy.  See "RetroTS.py -help" for details.

    step 1: analyze with afni_proc.py

            Consider these afni_proc.py -help examples:
               5b.  case of ricor and no bandpassing
               5c.  ricor and bandpassing and full registration
               9.   no ricor, but with bandpassing
               9b.  with WMeLocal (local white-matter, eroded) - ANATICOR
               10.  also with tissue-based regressors
               10b. apply bandpassing via 3dRSFC
               soon: extra motion regs via motion simulated time series
                     (either locally or not)
               11.  censor, despike, non-linear registration,
                    no bandpassing, fast ANATICOR regression,
                    FreeSurfer masks for ventricle/WM regression
                  * see "FREESURFER NOTE" for more details

        processing blocks:

            despike (shrink large spikes in time series)
            ricor   (if applicable, remove the RetroTS regressors)
            tshift  (correct for slice timing)
            align   (figure out alignment between anat and EPI)
            tlrc    (figure out alignment between anat and template)
            volreg  (align anat and EPI together, and to standard template)
            blur    (apply desired FWHM blur to EPI data)
            scale   (optional, e.g. before seed averaging)
            regress (polort, motion, mot deriv, bandpass, censor,
                     ANATICOR/WMeLocal, tedana)
                    (depending on chosen options)
                    soon: extra motion regressors (via motion simulation)

            ==> "result" is errts dataset, "cleaned" of known noise sources

    step 2: correlation analysis, perhaps with 3dGroupInCorr

        The inputs to this stage are the single subject errts datasets.

        Ignoring 3dGroupInCorr, the basic steps in a correlation analysis
        (and corresponding programs) are as follows.  This may be helpful
        for understanding the process, even when using 3dGroupInCorr.

            a. choose a seed voxel (or many) and maybe a seed radius

            for each subject:

               b. compute time series from seed
                  (3dmaskave or 3dROIstats)
               c. generate correlation map from seed TS
                  (3dTcorr1D (or 3dDeconvolve or 3dfim+))
               d. normalize R->"Z-score" via Fisher's z-transform
                  (3dcalc -expr atanh)

            e. perform group test, maybe with covariates
               (3dttest++: 1-sample, 2-sample or paired)

        To play around with a single subject via InstaCorr:

            a. start afni (maybe show images of both anat and EPI)
            b. start InstaCorr plugin from menu at top right of afni's
               Define Overlay panel
            c. Setup Icorr:
                c1. choose errts dataset
                   (no Start,End; no Blur (already done in pre-processing))
                c2. Automask -> No; choose mask dataset: full_mask
                c3. turn off Bandpassing (already done, if desired)
            d. in image window, show correlations
                d1. go to seed location, right-click, InstaCorr Set
                OR
                d1. hold ctrl-shift, hold left mouse button, drag
            e. have endless fun

        To use 3dGroupInCorr:

            a. run 3dSetupGroupIncorr with mask, labels, subject datasets
               (run once per group of subjects), e.g.

                    3dSetupGroupInCorr                \
                        -labels subj.ID.list.txt      \
                        -prefix sic.GROUP             \
                        -mask EPI_mask+tlrc           \
                        errts_subj1+tlrc              \
                        errts_subj2+tlrc              \
                        errts_subj3+tlrc              \
                            ...                       \
                        errts_subjN+tlrc

                ==> sic.GROUP.grpincorr.niml (and .grpincorr.data)

            b. run 3dGroupInCorr on 1 or 2 sic.GROUP datasets, e.g.

               Here are steps for running 3dGroupInCorr via the afni GUI.
               To deal with computers that have multiple users, consider
               specifying some NIML port block that others are not using.
               Here we use port 2 (-npb 2), just to choose one.

               b1. start afni:

                    afni -niml -npb 2

               b2. start 3dGroupInCorr

                    3dGroupInCorr -npb 2                    \
                        -setA sic.horses.grpincorr.niml     \
                        -setB sic.moths.grpincorr.niml      \
                        -labelA horses -labelB moths        \
                        -covaries my.covariates.txt         \
                        -center SAME -donocov -seedrad 5

               b3. play with right-click -> InstaCorr Set or
                  hold ctrl-shift/hold left mouse and drag slowly

               b4. maybe save any useful dataset via
                  Define Datamode -> SaveAs OLay (and give a useful name)

            b'. alternative, generate result dataset in batch mode, by
                adding -batch and some parameters to the 3dGIC command

                e.g.  -batch XYZAVE GIC.HvsM.PFC 4 55 26

                In such a case, afni is not needed at all.  The resulting
                GIC.HvsM.PFC+tlrc dataset would be written out without any
                need to start the afni GUI.  This works well since seed
                coordinates for group tests are generally known in advance.

                See the -batch option under "3dGroupInCorr -help" for many
                details and options.

            c. threshold/clusterize resulting datasets, just as with a
               task analysis

               (afni GUI, 3dClusterize)

--------------------------------------------------
FREESURFER NOTE: ~2~

FreeSurfer output can be used for a few things in afni_proc.py:

    - simple skull stripping (i.e. instead of 3dSkullStrip)
         *** we now prefer @SSwarper ***
    - running a surface-based analysis
    - using parcellation datasets for:
       - tissue-based regression
       - creating group probability maps
       - creating group atlases (e.g. maximum probability maps)

This NOTE mainly refers to using FreeSurfer parcellations for tissue-based
regression, as is done in Example 11.


First run FreeSurfer, then import to AFNI using @SUMA_Make_Spec_FS, then
make ventricle and white matter masks from the Desikan-Killiany atlas based
parcellation dataset, aparc+aseg.nii.

Note that the aparc.a2009s segmentations are based on the Destrieux atlas,
which might be nicer for probability maps, though the Desikan-Killiany
aparc+aseg segmentation is currently used for segmenting white matter and
ventricles.  I have not studied the differences.


Example 11 brings the aparc.a2009s+aseg segmentation along (for viewing or
atlas purposes, aligned with the result), though the white matter and
ventricle masks are based instead on aparc+aseg.nii.

    # run ) FreeSurfer on FT_anat.nii (NIFTI version of FT_anat+orig)
    3dcopy FT_anat+orig FT_anat.nii
    recon-all -all -subject FT -i FT_anat.nii

    # import to AFNI, in NIFTI format
    @SUMA_Make_Spec_FS -sid FT -NIFTI


  * Note, @SUMA_Make_Spec_FS now (as of 14 Nov, 2019) outputs ventricle
    and white matter masks, for possible use with afni_proc.py:

        SUMA/fs_ap_latvent.nii.gz
        SUMA/fs_ap_wm.nii.gz

Then FT_anat.nii (or FT_anat+orig), fs_ap_latvent.nii.gz and
fs_ap_wm.nii.gz (along with the basically unused
aparc.a2009s+aseg_REN_all.nii.gz) are passed to afni_proc.py.

--------------------------------------------------
TIMING FILE NOTE: ~2~

One issue that the user must be sure of is the timing of the stimulus
files (whether -regress_stim_files or -regress_stim_times is used).

The 'tcat' step will remove the number of pre-steady-state TRs that the
user specifies (defaulting to 0).  The stimulus files, provided by the
user, must match datasets that have had such TRs removed (i.e. the stim
files should start _after_ steady state has been reached).

--------------------------------------------------
MASKING NOTE: ~2~

The default operation of afni_proc.py has changed (as of 24 Mar, 2009).
Prior to that date, the default was to apply the 'epi' mask.  As of
17 Jun 2009, only the 'extents' mask is, if appropriate.

---

There may be 4 masks created by default, 3 for user evaluation and all for
possible application to the EPI data (though it may not be recommended).
The 4th mask (extents) is a special one that will be applied at volreg when
appropriate, unless the user specifies otherwise.

If the user chooses to apply one of the masks to the EPI regression (again,
not necessarily recommended), it is done via the option -mask_apply while
providing the given mask type (epi, anat, group or extents).

--> To apply a mask during regression, use -mask_apply.

Mask descriptions (afni_proc.py name, dataset name, short description):

1. epi ("full_mask") : EPI Automask

   An EPI mask dataset will be created by running '3dAutomask -dilate 1'
   on the EPI data after blurring.  The 3dAutomask command is executed per
   run, after which the masks are combined via a union operation.

2. anat ("mask_anat.$subj") : anatomical skull-stripped mask

   If possible, a subject anatomy mask will be created.  This anatomical
   mask will be created from the appropriate skull-stripped anatomy,
   resampled to match the EPI (that is output by 3dvolreg) and changed into
   a binary mask.

   This requires either the 'align' block or a tlrc anatomy (from the
   'tlrc' block, or just copied via '-copy_anat').  Basically, it requires
   afni_proc.py to know of a skull-stripped anatomical dataset.

   By default, if both the anat and EPI masks exist, the overlap between
   them will be computed for evaluation.

3. group ("mask_group") : skull-stripped @auto_tlrc base

   If possible, a group mask will be created.  This requires the 'tlrc'
   block, from which the @auto_tlrc -base dataset is chosen as the group
   anatomy.  It also requires '-volreg_warp_epi' so that the EPI is in
   standard space.  The group anatomy is then resampled to match the EPI
   and changed into a binary mask.

4. extents ("mask_extents") : mask based on warped EPI extents

   In the case of transforming the EPI volumes to match the anatomical
   volume (via either -volreg_align_e2a or -volreg_tlrc_warp), an extents
   mask will be created.  This is to avoid a motion artifact that arises
   when transforming from a smaller volume (EPI) to a larger one (anat).

** Danger Will Robinson! **

   This EPI extents mask is considered necessary because the align/warp
   transformation that is applied on top of the volreg alignment transform
   (applied at once), meaning the transformation from the EPI grid to the
   anatomy grid will vary per TR.

   The effect of this is seen at the edge voxels (extent edge), where a
   time series could be zero for many of the TRs, but have valid data for
   the rest of them.  If this timing just happens to correlate with any
   regressor, the result could be a strong "activation" for that regressor,
   but which would be just a motion based artifact.

   What makes this particularly bad is that if it does happen, it tends to
   happen for *a cluster* of many voxels at once, possibly an entire slice.
   Such an effect is compounded by any additional blur.  The result can be
   an entire cluster of false activation, large enough to survive multiple
   comparison corrections.

   Thanks to Laura Thomas and Brian Bones for finding this artifact.

-> To deal with this, a time series of all 1s is created on the original
   EPI grid space.  Then for each run it is warped with to the same list of
   transformations that is applied to the EPI data in the volreg step
   (volreg xform and either alignment to anat or warp to standard space).
   The result is a time series of extents of each original volume within
   the new grid.

   These volumes are then intersected over all TRs of all runs.  The final
   mask is the set of voxels that have valid data at every TR of every run.
   Yay.

5. Classes and Classes_resam: GM, WM, CSF class masks from 3dSeg

   By default, unless the user requests otherwise (-mask_segment_anat no),
   and if anat_final is skull-stripped, then 3dSeg will be used to segment
   the anatomy into gray matter, white matter and CSF classes.

   A dataset named Classes is the result of running 3dSeg, which is then
   resampled to match the EPI and named Classes_resam.

   If the user wanted to, this dataset could be used for regression of
   said tissue classes (or eroded versions).


--- masking, continued...

Note that it may still not be a good idea to apply any of the masks to the
regression, as it might then be necessary to intersect such masks across
all subjects, though applying the 'group' mask might be reasonable.

Why has the default been changed?

It seems much better not to mask the regression data in the single-subject
analysis at all, send _all_ of the results to group space, and apply an
anatomically-based mask there.  That could be computed from the @auto_tlrc
reference dataset or from the union of skull-stripped subject anatomies.

Since subjects have varying degrees of signal dropout in valid brain areas
of the EPI data, the resulting EPI intersection mask that would be required
in group space may exclude edge regions that are otherwise desirable.

Also, it is helpful to see if much 'activation' appears outside the brain.
This could be due to scanner or interpolation artifacts, and is useful to
note, rather than to simply mask out and never see.

Rather than letting 3dAutomask decide which brain areas should not be
considered valid, create a mask based on the anatomy _after_ the results
have been warped to a standard group space.  Then perhaps dilate the mask
by one voxel.  Example #11 from '3dcalc -help' shows how one might dilate.

Note that the EPI data can now be warped to standard space at the volreg
step.  In that case, it might be appropriate to mask the EPI data based
on the Talairach template, such as what is used for -base in @auto_tlrc.
This can be done via '-mask_apply group'.

---

For those who have processed some of their data with the older method:

Note that this change should not be harmful to those who have processed
data with older versions of afni_proc.py, as it only adds non-zero voxel
values to the output datasets.  If some subjects were analyzed with the
older version, the processing steps should not need to change.  It is still
necessary to apply an intersection mask across subjects in group space.

It might be okay to create the intersection mask from only those subjects
which were masked in the regression, however one might say that biases the
voxel choices toward those subjects, though maybe that does not matter.
Any voxels used would still be across all subjects.

---

A mask dataset is necessary when computing blur estimates from the epi and
errts datasets.  Also, since it is nice to simply see what the mask looks
like, its creation has been left in by default.

The '-regress_no_mask' option is now unnecessary.

---

Note that if no mask were applied in the 'scaling' step, large percent
changes could result.  Because large values would be a detriment to the
numerical resolution of the scaled short data, the default is to truncate
scaled values at 200 (percent), which should not occur in the brain.

--------------------------------------------------
BLIP NOTE: ~2~

application of reverse-blip (blip-up/blip-down) registration:

   o compute the median of the forward and reverse-blip data
   o align them using 3dQwarp -plusminus
      -> the main output warp is the square root of the forward warp
         to the reverse, i.e. it warps the forward data halfway
      -> in theory, this warp should make the EPI anatomically accurate

order of operations:

   o the blip warp is computed after all initial temporal operations
     (despike, ricor, tshift)
   o and before all spatial operations (anat/EPI align, tlrc, volreg)

notes:

   o If no forward blip time series (volume?) is provided by the user,
     the first time points from the first run will be used (using the
     same number of time points as in the reverse blip time series).
   o As usual, all registration transformations are combined.

differences with unWarpEPI.py (R Cox, D Glen and V Roopchansingh):

                    afni_proc.py            unWarpEPI.py
                    --------------------    --------------------
   tshift step:     before unwarp           after unwarp
                    (option: after unwarp)

   volreg program:  3dvolreg                3dAllineate

   volreg base:     as before               median warped dset
                    (option: MEDIAN_BLIP)   (same as MEDIAN_BLIP)

   unifize EPI?     no (option: yes)        yes
   (align w/anat)

--------------------------------------------------
ANAT/EPI ALIGNMENT CASES NOTE: ~2~

This outlines the effects of alignment options, to help decide what options
seem appropriate for various cases.

1. EPI to EPI alignment (the volreg block)

    Alignment of the EPI data to a single volume is based on the 3 options
    -volreg_align_to, -volreg_base_dset and -volreg_base_ind, where the
    first option is by far the most commonly used.

    Note that a good alternative is: '-volreg_align_to MIN_OUTLIER'.

    The logic of EPI alignment in afni_proc.py is:

        a. if -volreg_base_dset is given, align to that
           (this volume is copied locally as the dataset ext_align_epi)
        b. otherwise, use the -volreg_align_to or -volreg_base_ind volume

    The typical case is to align the EPI to one of the volumes used in
    pre-processing (where the dataset is provided by -dsets and where the
    particular TR is not removed by -tcat_remove_first_trs).  If the base
    volume is the first or third (TR 0 or 2) from the first run, or is the
    last TR of the last run, then -volreg_align_to can be used.

    To specify a TR that is not one of the 3 just stated (first, third or
    last), -volreg_base_ind can be used.

    To specify a volume that is NOT one of those used in pre-processing
    (such as the first pre-steady state volume, which would be excluded by
    the option -tcat_remove_first_trs), use -volreg_base_dset.

2. anat to EPI alignment cases (the align block)

    This is specific to the 'align' processing block, where the anatomy is
    aligned to the EPI.  The focus is on which EPI volume the anat gets
    aligned to.  Whether this transformation is inverted in the volreg
    block (to instead align the EPI to the anat via -volreg_align_e2a) is
    an independent consideration.

    The logic of which volume the anatomy gets aligned to is as follows:
        a. if -align_epi_ext_dset is given, use that for anat alignment
        b. otherwise, if -volreg_base_dset, use that
        c. otherwise, use the EPI base from the EPI alignment choice

    To restate this: the anatomy gets aligned to the same volume the EPI
    gets aligned to *unless* -align_epi_ext_dset is given, in which case
    that volume is used.

    The entire purpose of -align_epi_ext_dset is for the case where the
    user might want to align the anat to a different volume than what is
    used for the EPI (e.g. align anat to a pre-steady state TR but the EPI
    to a steady state one).

    Output:

       The result of the align block is an 'anat_al' dataset.  This will be
       in alignment with the EPI base (or -align_epi_ext_dset).

       In the default case of anat -> EPI alignment, the aligned anatomy
       is actually useful going forward, and is so named 'anat_al_keep'.

       Additionally, if the -volreg_align_e2a option is used (thus aligning
       the EPI to the original anat), then the aligned anat dataset is no
       longer very useful, and is so named 'anat_al_junk'.  However, unless
       an anat+tlrc dataset was copied in for use in -volreg_tlrc_adwarp,
       the skull-striped anat (anat_ss) becomes the current one going
       forward.  That is identical to the original anat, except that it
       went through the skull-stripping step in align_epi_anat.py.

       At that point (e2a case) the pb*.volreg.* datasets are aligned with
       the original anat or the skull-stripped original anat (and possibly
       in Talairach space, if the -volreg_tlrc_warp or _adwarp option was
       applied).

     Checking the results:

       The pb*.volreg.* volumes should be aligned with the anat.  If
       -volreg_align_e2a was used, it will be with the original anat.
       If not, then it will be with anat_al_keep.

       Note that at the end of the regress block, whichever anatomical
       dataset is deemed "in alignment" with the stats dataset will be
       copied to anat_final.$subj.

       So compare the volreg EPI with the final anatomical dataset.

--------------------------------------------------
ANAT/EPI ALIGNMENT CORRECTIONS NOTE: ~2~

Aligning the anatomy and EPI is sometimes difficult, particularly depending
on the contrast of the EPI data (between tissue types).  If the alignment
fails to do a good job, it may be necessary to run align_epi_anat.py in a
separate location, find options that help it to succeed, and then apply
those options to re-process the data with afni_proc.py.

1. If the anat and EPI base do not start off fairly close in alignment,
   the -giant_move option may be needed for align_epi_anat.py.  Pass this
   option to AEA.py via the afni_proc.py option -align_opts_aea:

        afni_proc.py ... -align_opts_aea -giant_move

2. The default cost function used by align_epi_anat.py is lpc (local
   Pearson correlation).  If this cost function does not work (probably due
   to poor or unusual EPI contrast), then consider cost functions such as
   lpa (absolute lpc), lpc+ (lpc plus fractions of other cost functions) or
   lpc+ZZ (approximate with lpc+, but finish with pure lpc).

   The lpa and lpc+ZZ cost functions are common alternatives.  The
   -giant_move option may be necessary independently.

   Examples of some helpful options:

     -align_opts_aea -cost lpa
     -align_opts_aea -giant_move
     -align_opts_aea -cost lpc+ZZ -giant_move
     -align_opts_aea -check_flip
     -align_opts_aea -cost lpc+ZZ -giant_move -resample off
     -align_opts_aea -skullstrip_opts -blur_fwhm 2

3. Testing alignment with align_epi_anat.py directly.

   When having alignment problems, it may be more efficient to copy the
   anat and EPI alignment base to a new directory, figure out a good cost
   function or other options, and then apply them in a new afni_proc.py
   command.

   For testing purposes, it helps to test many cost functions at once.
   Besides the cost specified by -cost, other cost functions can be applied
   via -multi_cost.  This is efficient, since all of the other processing
   does not need to be repeated.  For example:

     align_epi_anat.py -anat2epi                    \
            -anat subj99_anat+orig                  \
            -epi pb01.subj99.r01.tshift+orig        \
            -epi_base 0 -volreg off -tshift off     \
            -giant_move                             \
            -cost lpc -multi_cost lpa lpc+ZZ mi

   That adds -giant_move, and uses the basic lpc cost function along with
   3 additional cost functions (lpa, lpc+ZZ, mi).  The result is 4 new
   anatomies aligned to the EPI, 1 per cost function:

           subj99_anat_al+orig         - cost func lpc      (see -cost opt)
           subj99_anat_al_lpa+orig     - cost func lpa         (additional)
           subj99_anat_al_lpc+ZZ+orig  - cost func lpc+ZZ      (additional)
           subj99_anat_al_mi+orig      - cost func mi          (additional)

   Also, if part of the dataset gets clipped in the case of -giant_move,
   consider the align_epi_anat.py option '-resample off'.

--------------------------------------------------
WARP TO TLRC NOTE: ~2~

afni_proc.py can now apply a +tlrc transformation to the EPI data as part
of the volreg step via the option '-volreg_tlrc_warp'.  Note that it can
also align the EPI and anatomy at the volreg step via '-volreg_align_e2a'.

Manual Talairach transformations can also be applied, but separately, after
volreg.  See '-volreg_tlrc_adwarp'.

This tlrc transformation is recommended for many reasons, though some are
not yet implemented.  Advantages include:

    - single interpolation of the EPI data

        Done separately, volume registration, EPI to anat alignment and/or
        the +tlrc transformation interpolate the EPI data 2 or 3 times.  By
        combining these transformations into a single one, there is no
        resampling penalty for the alignment or the warp to standard space.

        Thanks to D Glen for the steps used in align_epi_anat.py.

    - EPI time series become directly comparable across subjects

        Since the volreg output is now in standard space, there is already
        voxel correspondence across subjects with the EPI data.

    - group masks and/or atlases can be applied to the EPI data without
      additional warping

        It becomes trivial to extract average time series data over ROIs
        from standard atlases, say.

        This could even be done automatically with afni_proc.py, as part
        of the single-subject processing stream (not yet implemented).
        One would have afni_proc.py extract average time series (or maybe
        principal components) from all the ROIs in a dataset and apply
        them as regressors of interest or of no interest.

    - no interpolation of statistics

        If the user wishes to include statistics as part of the group
        analysis (e.g. using 3dMEMA.R), this warping becomes more needed.
        Warping to standard space *after* statistics are generated is not
        terribly valid.

--------------------------------------------------
RETROICOR NOTE: ~2~

** Cardiac and respiratory regressors must be created from an external
   source, such as the RetroTS.py program written by Z Saad, and converted
   to python by J Zosky.  The input to that should be the 2+ signals.  The
   output should be a single file per run, containing 13 or more regressors
   for each slice.  That set of output files would be applied here in
   afni_proc.py.

Removal of cardiac and respiratory regressors can be done using the 'ricor'
processing block.  By default, this would be done after 'despike', but
before any other processing block.

These card/resp signals would be regressed out of the MRI data in the
'ricor' block, after which processing would continue normally. In the final
'regress' block, regressors for slice 0 would be applied (to correctly
account for the degrees of freedom and also to remove residual effects).
    --> This is now only true when using '-regress_apply_ricor yes'.
        The default as of 30 Jan 2012 is to not include them in the final
        regression (since degrees of freedom are really not important for a
        subsequent correlation analysis).

Users have the option of removing the signal "per-run" or "across-runs".

Example R1: 7 runs of data, 13 card/resp regressors, process "per-run"

    Since the 13 regressors are processed per run, the regressors can have
    different magnitudes each run.  So the 'regress' block will actually
    get 91 extra regressors (13 regressors times 7 runs each).

Example R2: process "across-run"

    In this case the regressors are catenated across runs when they are
    removed from the data.  The major difference between this and "per-run"
    is that now only 1 best fit magnitude is applied per regressor (not the
    best for each run).  So there would be only the 13 catenated regressors
    for slice 0 added to the 'regress' block.

Those analyzing resting-state data might prefer the per-run method, as it
would remove more variance and degrees of freedom might not be as valuable.

Those analyzing a normal signal model might prefer doing it across-runs,
giving up only 13 degrees of freedom, and helping not to over-model the
data.

** The minimum options would be specifying the 'ricor' block (preferably
   after despike), along with -ricor_regs and -ricor_regress_method.

Example R3: afni_proc.py option usage:

    Provide additional options to afni_proc.py to apply the despike and
    ricor blocks (which will be the first 2 blocks by default), with each
    regressor named 'slibase*.1D' going across all runs, and where the
    first 3 TRs are removed from each run (matching -tcat_remove_first_trs,
    most likely).

        -do_block despike ricor
        -ricor_regs slibase*.1D
        -ricor_regress_method across-runs
        -ricor_regs_nfirst 3

--------------------------------------------------
MULTI ECHO NOTE: ~2~

    rcr - todo

In the case of multi-echo data, there are many things to consider.
-combine_method
-mask_epi_anat yes
-blocks ... mask combine ...

    see TEDANA NOTE
--------------------------------------------------
TEDANA NOTE: ~2~

This deserves its own section.
-tshift_interp -wsinc9
-mask_epi_anat yes
-volreg_warp_final_interp wsinc5

    see MULTI ECHO NOTE
--------------------------------------------------
RUNS OF DIFFERENT LENGTHS NOTE: ~2~

In the case that the EPI datasets are not all of the same length, here
are some issues that may come up, listed by relevant option:

    -volreg_align_to        OK, as of version 1.49.

    -ricor_regress_method   OK, as of version 3.05.

    -regress_polort         Probably no big deal.
                            If this option is not used, then the degree of
                            polynomial used for the baseline will come from
                            the first run.  Only 1 polort may be applied.

    -regress_est_blur_epits OK, as of version 1.49.

 *  -regress_use_stim_files This may fail, as make_stim_times.py is not
                            currently prepared to handle runs of different
                            lengths.

    -regress_censor_motion  OK, as of version 2.14

 * probably will be fixed (please let me know of interest)

--------------------------------------------------
SCRIPT EXECUTION NOTE: ~2~

The suggested way to run the output processing SCRIPT is via...

    a) if you use tcsh:    tcsh -xef SCRIPT |& tee output.SCRIPT

    b) if you use bash:    tcsh -xef SCRIPT 2>&1 | tee output.SCRIPT

    c) if you use tcsh and the script is executable, maybe use one of:

                        ./SCRIPT |& tee output.SCRIPT
                        ./SCRIPT 2>&1 | tee output.SCRIPT

Consider usage 'a' for example:  tcsh -xef SCRIPT |& tee output.SCRIPT

That command means to invoke a new tcsh with the -xef options (so that
commands echo to the screen before they are executed, exit the script
upon any error, do not process the ~/.cshrc file) and have it process the
SCRIPT file, piping all output to the 'tee' program, which will duplicate
output back to the screen, as well as to the given output file.

parsing the command: tcsh -xef SCRIPT |& tee output.SCRIPT

    a. tcsh

       The script itself is written in tcsh syntax and must be run that way.
       It does not mean the user must use tcsh.  Note uses 'a' and 'b'.
       There tcsh is specified by the user.  The usage in 'c' applies tcsh
       implicitly, because the SCRIPT itself specifies tcsh at the top.

    b. tcsh -xef

       The -xef options are applied to tcsh and have the following effects:

            x : echo commands to screen before executing them
            e : exit (terminate) the processing on any errors
            f : do not process user's ~/.cshrc file

       The -x option is very useful so one see not just output from the
       programs, but the actual commands that produce the output.  It
       makes following the output much easier.

       The -e option tells the shell to terminate on any error.  This is
       useful for multiple reasons.  First, it allows the user to easily
       see the failing command and error message.  Second, it would be
       confusing and useless to have the script try to continue, without
       all of the needed data.

       The -f option tells the shell not to process the user's ~/.cshrc
       (or ~/.tcshrc) file.  The main reason for including this is because
       of the -x option.  If there were any errors in the user's ~/.cshrc
       file and -x option were used, they would terminate the shell before
       the script even started, probably leaving the user confused.

    c. tcsh -xef SCRIPT

       The T-shell is invoked as described above, executing the contents
       of the specified text file (called 'SCRIPT', for example) as if the
       user had typed the included commands in their terminal window.

    d. |&

       These symbols are for piping the output of one program to the input
       of another.  Many people know how to do 'afni_proc.py -help | less'
       (or maybe '| more').  This script will output a lot of text, and we
       want to get a copy of that into a text file (see below).

       Piping with '|' captures only stdout (standard output), and would
       not capture errors and warnings that appear.  Piping with '|&'
       captures both stdout and stderr (standard error).  The user may not
       be able to tell any difference between those file streams on the
       screen, but since programs write to both, we want to capture both.

    e. tee output.SCRIPT

       Where do we want to send this captured stdout and stderr text?  Send
       it to the 'tee' program.  Like a plumber's tee, the 'tee' program
       splits the data (not water) stream off into 2 directions.

       Here, one direction that tee sends the output is back to the screen,
       so the user can still see what is happening.

       The other direction is to the user-specified text file.  In this
       example it would be 'output.SCRIPT'.  With this use of 'tee', all
       screen output will be duplicated in that text file.



==================================================
OPTIONS:  ~2~

    Informational options, general options, and block options.
    Block options are ordered by block.

    -----------------------------------------------------------------
    Informational/terminal options  ~3~

    -help                   : show the complete help

    -help_section SECTION   : show help for given SECTION

        The help is divided into sections, an any one of these can be
        displayed individually by providing the given SECTION:

              intro         - introduction
              examples      - afni_proc.py command examples
              notes         - NOTE_* entries
              options       - descriptions of options
              trailer       - final trailer

    -help_tedana_files      : show tedana file names, compare orig vs bids

       The file naming between older and newer tedana versions (or newer
       using "tedana --convention orig") is shown with this option.  For
       example, the denoised time series after being Optimally Combined
       has possible names of:

           orig                 BIDS
           ----                 ----
           dn_ts_OC.nii.gz      desc-optcomDenoised_bold.nii.gz          

        Please see 'tedana --help' for more information.

    -hist                   : show the module history

    -hist_milestones        : show the history of interesting milestones

    -requires_afni_version  : show AFNI date required by processing script

        Many updates to afni_proc.py are accompanied by corresponding
        updates to other AFNI programs.  So if the processing script is
        created on one computer but executed on another (with an older
        version of AFNI), confusing failures could result.

        The required date is adjusted whenever updates are made that rely
        on new features of some other program.  If the processing script
        checks the AFNI version, the AFNI package must be as current as the
        date output via this option.  Checks are controlled by the option
        '-check_afni_version'.

        The checking method compares the output of:
            afni_proc.py -requires_afni_version

        against the most recent date in afni_history:
            afni_history -past_entries 1

        See also '-requires_afni_hist'.

        See also '-check_afni_version'.

    -requires_afni_hist     : show history of -requires_afni_version

        List the history of '-requires_afni_version' dates and reasons.

    -show_valid_opts        : show all valid options (brief format)

    -show_example NAME      : display the given example command

            e.g. afni_proc.py -show_example 'example 6b'
            e.g. afni_proc.py -show_example 'example 6b' -verb 0
            e.g. afni_proc.py -show_example 'example 6b' -verb 2

        Display the given afni_proc.py help example.  Details shown depend
        on the verbose level, as specified with -verb:

            0: no formatting - command can be copied and applied elsewhere
            1: basic         - show header and formatted command
            2: detailed      - include full description, as in -help output

        To list examples that can be shown, use:

            afni_proc.py -show_example_names

        See also '-show_example_names'.

    -show_example_names     : show names of all sample commands
                              (possibly for use with -compare options)

            e.g. afni_proc.py -show_example_names
            e.g. afni_proc.py -show_example_names -verb 3

        Use this command to list the current examples know by afni_proc.py.
        The format of the output is affected by -verb, with -verb 2 format
        being the default.

        Adding -verb 3 will display the most recent modification date.

    -show_example_keywords  : show keywords associated with all examples

            e.g. afni_proc.py -show_example_keywords
            e.g. afni_proc.py -show_example_keywords -verb 2

        Use this command to list the current examples know by afni_proc.py.
        The format of the output is affected by -verb, with -verb 2 format
        being the default.

    -show_pretty_command    : output the same command, but in a nice format

            e.g. afni_proc.py -show_pretty_command

        Adding this option to an existing afni_proc.py command will result in
        displaying the command itself in a nicely indented manner, using the
        P Taylor special routines.

    -show_pythonic_command  : output the same command, but as a python list

            e.g. afni_proc.py -show_pythonic_command

        Adding this option to an existing afni_proc.py command will result in
        displaying the command itself, but in a python list format that is
        helpful to me.

    -ver                    : show the version number

    -----------------------------------------------------------------
    Terminal 'compare' options ~3~

    These options are used to help compare one afni_proc.py command with a
    different one.  One can compare a current command to a given example,
    one example to another, or one command to another.

    To see a list of examples one can compare against, consider:

        afni_proc.py -show_example_names

    -compare_example_pair EG1 EG2 : compare options for pair of examples

            e.g. -compare_example_pair 'example 6' 'example 6b'

        more completely:

            afni_proc.py -compare_example_pair 'example 6' 'example 6b'

        This option allows one to compare a pair of pre-defined examples
        (from the list in 'afni_proc.py -show_example_names').  It is like
        using -compare_opts, but for comparing example vs. example.

    -compare_opts EXAMPLE   : compare current options against EXAMPLE

            e.g. -compare_opts 'example 6b'

        more completely:

            afni_proc.py  ... my options ...  -compare_opts 'example 6b'

        Adding this option (and parameter) to an existing afni_proc.py
        command results in comparing the options applied in the current
        command against those of the specified target example.

        The afni_proc.py command terminates after showing the comparison
        output.

        The output from this is controlled by the -verb LEVEL:

            0       : show (python-style) lists of differing options
            1 (def) : include parameter differences
                      (except where expected, e.g. -copy_anat dset)
                      (limit param lists to current text line)
            2       : show complete parameter diffs

        Types of differences shown include:

            missing options         :
                where the current command is missing options that the
                specified target command includes
            extra options           :
                where the current command has extra options that the
                specified target command is missing
            differing options       :
                where the current command and target use the same option,
                but their parameters differ
            fewer applied options   :
                where the current command and target use multiple copies of
                the same option, but the current command has fewer
                (what is beyond the matching/differing cases)
            more applied options    :
                where the current command and target use multiple copies of
                the same option, but the current command has more
                (what is beyond the matching/differing cases)

        This option is the basis for all of the -compare* options.

        See also -show_example_names.

    -compare_opts_vs_opts opts... : compare 2 full commands

        more completely:

            afni_proc.py                            \
                ... one full set of options ...     \
                -compare_opts_vs_opts               \
                ... another full set of options ...

        Like other -compare_* options, but this compares 2 full commands,
        separated by -compare_opts_vs_opts.  This is a comparison method
        for comparing 2 local commands, rather than against any known
        example.

    -----------------------------------------------------------------
    General execution and setup options ~3~

    -anat_follower LABEL GRID DSET : specify anat follower dataset

            e.g. -anat_follower GM anat FS_GM_MASK.nii

        Use this option to pass any anatomical follower dataset.  Such a
        dataset is warped by any transformations that take the original
        anat to anat_final.

        Anatomical follower datasets are resampled using wsinc5.  The only
        difference with -anat_follower_ROI is that such ROI datasets are
        resampled using nearest neighbor interpolation.

           LABEL    : to name and refer to this dataset
           GRID     : which grid should this be sampled on, anat or epi?
           DSET     : name of input dataset, changed to copy_af_LABEL

        A default anatomical follower (in the case of skull stripping) is
        the original anat.  That is to get a warped version that still has
        a skull, for quality control.

        See also -anat_follower_ROI, anat_follower_erode.

    -anat_follower_erode LABEL LABEL ...: erode masks for given labels

            e.g. -anat_follower_erode WMe

        Perform a single erosion step on the mask dataset for the given
        label.  This is done on the input ROI (anatomical?) grid.

        The erosion step is applied before any transformation, and uses the
        18-neighbor approach (6 face and 12 edge neighbors, not 8 corner
        neighbors) in 3dmask_tool.

      * For more control on the erosion level, see -anat_follower_erode_level.

        See also -anat_follower_erode_level, -regress_ROI_PC, -regress_ROI.
        Please see '3dmask_tool -help' for more information on eroding.

    -anat_follower_erode_level LABEL LEVEL : erode a mask at a specific level

            e.g. -anat_follower_erode_level WMe 2

        Use this option to specify an anatomical erosion level, in voxels.

        The erosion step is applied before any transformation, and uses the
        18-neighbor approach (6 face and 12 edge neighbors, not 8 corner
        neighbors) in 3dmask_tool.

      * For more control on the erosion level, see -anat_follower_erode_level.

        See also -anat_follower_erode_level, -regress_ROI_PC, -regress_ROI.
        Please see '3dmask_tool -help' for more information on eroding.

    -anat_follower_ROI LABEL GRID DSET : specify anat follower ROI dataset

        e.g. -anat_follower_ROI aaseg anat aparc.a2009s+aseg_REN_all.nii.gz
        e.g. -anat_follower_ROI FSvent epi fs_ap_latvent.nii.gz

        Use this option to pass any anatomical follower dataset.  Such a
        dataset is warped by any transformations that take the original
        anat to anat_final.

        Similar to -anat_follower, except that these anatomical follower
        datasets are resampled using nearest neighbor (NN) interpolation,
        to preserve data values (as opposed to -anat_follower, which uses
        wsinc5).  That is the only difference between these options.

           LABEL    : to name and refer to this dataset
           GRID     : which grid should this be sampled on, anat or epi?
           DSET     : name of input dataset, changed to copy_af_LABEL

        Labels defined via this option may be used in -regress_ROI or _PC.

        See also -anat_follower, anat_follower_erode, -regress_ROI
        or -regress_ROI_PC.

    -anat_has_skull yes/no  : specify whether the anatomy has a skull

            e.g. -anat_has_skull no

        Use this option to block any skull-stripping operations, likely
        either in the align or tlrc processing blocks.

    -anat_uniform_method METHOD : specify uniformity correction method

            e.g. -anat_uniform_method unifize

        Specify the method for anatomical intensity uniformity correction.

            none    : do not do uniformity correction at all
            default : use 3dUnifize at whim of auto_warp.py
            unifize : apply 3dUnifize early in processing stream
                      (so it affects more than auto_warp.py)

        Please see '3dUnifize -help' for details.
        See also -anat_opts_unif.

    -anat_opts_unif OPTS ... : specify extra options for unifize command

            e.g. -anat_opts_unif -Urad 14

        Specify options to be applied to the command used for anatomical
        intensity uniformity correction, such as 3dUnifize.

        Please see '3dUnifize -help' for details.
        See also -anat_uniform_method.

    -anat_unif_GM yes/no    : also unifize gray matter (lower intensities)
                              the default is 'no'

            e.g. -anat_unif_GM yes
            default: -anat_unif_GM no

        If this is set to yes, 3dUnifize will not only apply uniformity
        correction across the brain volume, but also to voxels that look
        like gray matter.  That is to say the option adds '-GM' to the
        3dUnifize command.

      * The default was changed from yes to no 2014, May 16.

        Please see '3dUnifize -help' for details.
        See also -anat_uniform_method, -anat_opts_unif.

    -ask_me                 : ask the user about the basic options to apply

        When this option is used, the program will ask the user how they
        wish to set the basic options.  The intention is to give the user
        a feel for what options to apply (without using -ask_me).

    -bash                   : show example execution command in bash form

        After the script file is created, this program suggests how to run
        it (piping stdout/stderr through 'tee').  If the user is running
        the bash shell, this option will suggest the 'bash' form of a
        command to execute the newly created script.

        example of tcsh form for execution:

            tcsh -x proc.ED.8.glt |& tee output.proc.ED.8.glt

        example of bash form for execution:

            tcsh -x proc.ED.8.glt 2>&1 | tee output.proc.ED.8.glt

        Please see "man bash" or "man tee" for more information.

    -blocks BLOCK1 ...      : specify the processing blocks to apply

            e.g. -blocks volreg blur scale regress
            e.g. -blocks despike tshift align volreg blur scale regress
            default: tshift volreg blur mask scale regress

        The user may apply this option to specify which processing blocks
        are to be included in the output script.  The order of the blocks
        may be varied, and blocks may be skipped.

        See also '-do_block' (e.g. '-do_block despike').

    -check_afni_version yes/no : check that AFNI is current enough

            e.g. -check_afni_version no
            default: yes

        Check that the version of AFNI is recent enough for processing of
        the afni_proc.py script.

        For the version check, the output of:
            afni_proc.py -requires_afni_version

        is tested against the most recent date in afni_history:
            afni_history -past_entries 1

        In the case that newer features in other programs might not be
        needed by the given afni_proc.py script (depending on the options),
        the user is left with this option to ignore the AFNI version check.

        Please see 'afni_history -help' or 'afni -ver' for more information.
        See also '-requires_afni_version'.

    -check_results_dir yes/no : check whether dir exists before proceeding

            e.g. -check_results_dir no
            default: yes

        By default, if the results directory already exists, the script
        will terminate before doing any processing.  Set this option to
        'no' to remove that check.

    -check_setup_errors yes/no : terminate on setup errors

            e.g. -check_setup_errors yes
            default: no

        Have the script check $status after each command in the setup
        processing block.  It is preferable to run the script using the
        -e option to tcsh (as suggested), but maybe the user does not wish
        to do so.

    -command_comment_style STYLE: set style for final AP command comment

            e.g. -command_comment_style pretty

        This controls the format for the trailing afni_proc.py commented
        command at the end of the proc script.  STYLE can be:

            none        - no trailing command will be included
            compact     - the original compact form will be included
            pretty      - the PT-special pretty form will be included

    -copy_anat ANAT         : copy the ANAT dataset to the results dir

            e.g. -copy_anat Elvis/mprage+orig

        This will apply 3dcopy to copy the anatomical dataset(s) to the
        results directory.  Note that if a +view is not given, 3dcopy will
        attempt to copy +acpc and +tlrc datasets, also.

        See also '3dcopy -help'.

    -copy_files file1 ...   : copy file1, etc. into the results directory

            e.g. -copy_files glt_AvsB.txt glt_BvsC.1D glt_eat_cheese.txt
            e.g. -copy_files contrasts/glt_*.txt

        This option allows the user to copy some list of files into the
        results directory.  This would happen before the tcat block, so
        such files may be used for other commands in the script (such as
        contrast files in 3dDeconvolve, via -regress_opts_3dD).

    -do_block BLOCK_NAME ...: add extra blocks in their default positions

            e.g. -do_block despike ricor
            e.g. -do_block align

        With this option, any 'optional block' can be applied in its
        default position.  This includes the following blocks, along with
        their default positions:

            despike : first (between tcat and tshift)
            ricor   : just after despike (else first)
            align   : before tlrc, before volreg
            tlrc    : after align, before volreg
            empty   : NO DEFAULT, cannot be applied via -do_block

        Any block not included in -blocks can be added via this option
        (except for 'empty').

        See also '-blocks', as well as the "PROCESSING BLOCKS" section of
        the -help output.

    -dsets dset1 dset2 ...  : (REQUIRED) specify EPI run datasets

            e.g. -dsets Elvis_run1+orig Elvis_run2+orig Elvis_run3+orig
            e.g. -dsets Elvis_run*.HEAD

        The user must specify the list of EPI run datasets to analyze.
        When the runs are processed, they will be written to start with
        run 1, regardless of whether the input runs were just 6, 7 and 21.

        Note that when using a wildcard it is essential for the EPI
        datasets to be alphabetical, as that is how the shell will list
        them on the command line.  For instance, epi_run1+orig through
        epi_run11+orig is not alphabetical.  If they were specified via
        wildcard their order would end up as run1 run10 run11 run2 ...

        Note also that when using a wildcard it is essential to specify
        the datasets suffix, so that the shell doesn't put both the .BRIK
        and .HEAD filenames on the command line (which would make it twice
        as many runs of data).

    -dsets_me_echo dset1 dset2 ...  : specify ME datasets for one echo
                                      (all runs with each option)

       These examples might correspond to 3 echoes across 4 runs.

            e.g. -dsets_me_echo epi_run*.echo_1+orig.HEAD
                 -dsets_me_echo epi_run*.echo_2+orig.HEAD
                 -dsets_me_echo epi_run*.echo_3+orig.HEAD

            e.g. -dsets_me_echo r?.e1.nii
                 -dsets_me_echo r?.e2.nii
                 -dsets_me_echo r?.e3.nii

            e.g. -dsets_me_echo r1.e1.nii r2.e1.nii r3.e1.nii r4.e1.nii
                 -dsets_me_echo r1.e2.nii r2.e2.nii r3.e2.nii r4.e2.nii
                 -dsets_me_echo r1.e3.nii r2.e3.nii r3.e3.nii r4.e3.nii

        This option is convenient when there are more runs than echoes.

        When providing multi-echo data to afni_proc.py, doing all echoes
        of all runs at once seems messy and error prone.  So one must
        provide either one echo at a time (easier if there are more runs)
        or one run at a time (easier if there are fewer runs).

        With this option:

           - use one option per echo (as opposed to per run, below)
           - each option use should list all run datasets for that echo

        For example, if there are 7 runs and 3 echoes, use 3 options, one
        per echo, and pass the 7 runs of data for that echo in each.

        See also -dsets_me_run.
        See also -echo_times and -reg_echo.

    -dsets_me_run dset1 dset2 ...   : specify ME datasets for one run
                                      (all echoes with each option)

       These examples might correspond to 4 echoes across 2 runs.

            e.g. -dsets_me_run epi_run1.echo_*+orig.HEAD
                 -dsets_me_run epi_run2.echo_*+orig.HEAD

            e.g. -dsets_me_run r1.e*.nii
                 -dsets_me_run r2.e*.nii

            e.g. -dsets_me_run r1.e1.nii r1.e2.nii r1.e3.nii r1.e4.nii
                 -dsets_me_run r2.e1.nii r2.e2.nii r2.e3.nii r2.e4.nii

        This option is convenient when there are more echoes than runs.

        When providing multi-echo data to afni_proc.py, doing all echoes
        of all runs at once seems messy and error prone.  So one must
        provide either one echo at a time (easier if there are more runs)
        or one run at a time (easier if there are fewer runs).

        With this option:

           - use one option per run (as opposed to per echo, above)
           - each option use should list all echo datasets for that run

        For example, if there are 2 runs and 4 echoes, use 2 options, one
        per run, and pass the 4 echoes of data for that run in each.

        See also -dsets_me_echo.
        See also -echo_times and -reg_echo.

    -echo_times TE1 TE2 TE3 ... : specify echo-times for ME data processing

            e.g. -echo_times 20 30.5 41.2

        Use this option to specify echo times, if they are needed for the
        'combine' processing block (OC/ME-ICA/tedana).

        See also -combine_method.

    -execute                : execute the created processing script

        If this option is applied, not only will the processing script be
        created, but it will then be executed in the "suggested" manner,
        such as via:

            tcsh -xef proc.sb23 |& tee output.proc.sb23

        Note that it will actually use the bash format of the command,
        since the system command (C and therefore python) uses /bin/sh.

            tcsh -xef proc.sb23 2>&1 | tee output.proc.sb23

    -exit_on_error yes/no   : set whether proc script should exit on error

            e.g.     -exit_on_error no
            default: -exit_on_error yes

        This option affects how the program will suggest running any
        created proc script, as well as how one would be run if -execute
        is provided.

        If the choice is 'yes' (the default), the help for how to run the
        proc script (terminal and in script, itself) will show running it
        via "tcsh -xef", where the 'e' parameter says to exit on error.
        For example (using tcsh notation):

            tcsh -xef proc.sb23 |& tee output.proc.sb23

        If the choice is 'no', then it will suggest using simply "tcsh -x".
        For example (using tcsh notation):

            tcsh -x proc.sb23 |& tee output.proc.sb23

        This is also applied when using -execute, where afni_proc.py itself 
        runs the given system command.

        See also -execute.

    -find_var_line_blocks B0 B1 ... : specify blocks for find_variance_lines

            default: -find_var_line_blocks tcat
            e.g. -find_var_line_blocks tcat volreg
            e.g. -find_var_line_blocks NONE

        With this option set, find_variance_lines.tcsh will be run at the end
        of each listed block.  It looks for columns of high temporal variance 
        (looking across slices) in the time series data.

        Valid blocks include:

            tcat, tshift, volreg, blur, scale, NONE

        Since 'tcat' is the default block used, this option is turned off by
        using NONE as a block.

        See 'find_variance_lines.tcsh -help' for details.

    -gen_epi_review SCRIPT_NAME : specify script for EPI review

            e.g. -gen_epi_review review_orig_EPI.txt

        By default, the proc script calls gen_epi_review.py on the original
        EPI data (from the tcat step, so only missing pre-SS TRs).  This
        creates a "drive afni" script that the user can run to quickly scan
        that EPI data for apparent issues.

        Without this option, the script will be called @epi_review.$subj,
        where $subj is the subject ID.

        The script starts afni, loads the first EPI run and starts scanning
        through time (effectively hitting 'v' in the graph window).  The
        user can press <enter> in the prompting terminal window to go to
        each successive run.

        Note that the user has full control over afni, aside from a new run
        being loaded whey they hit <enter>.  Recall that the <space> key
        (applied in the graph window) can terminate the 'v' (video mode).

        See 'gen_epi_review.py -help' for details.
        See also 'no_epi_review', to disable this feature.

    -no_epi_review

        This option is used to prevent writing a gen_epi_review.py command
        in the processing script (i.e. do not create a script to review the
        EPI data).

        The only clear reason to want this option is if gen_epi_review.py
        fails for some reason.  It should not hurt to create that little
        text file (@epi_review.$subj, by default).

        See also '-gen_epi_review'.

    -html_review_opts  ...   : pass extra options to apqc_make_tcsh.py

            e.g. -html_review_opts -mot_grayplot_off
            e.g. -html_review_opts -vstat_list vis aud V-A

        Blindly pass the given options to apqc_make_tcsh.py.

    -html_review_style STYLE : specify generation method for HTML review

            e.g.     -html_review_style pythonic
            default: -html_review_style basic

        At the end of processing, by default, the proc script will generate
        quality control images and other information that is akin to 
        running @ss_review_driver (the minimum QC suggested for every
        subject).  This information will be stored in a static HTML page,
        for an optional, quick review.

        Use this option to specify the STYLE of the pages:

            none     : no HTML review pages
            basic    : static - time graph images generated by 1dplot
            pythonic : static - time graph images generated in python

            more to come?  pester Paul...
            STYLE omnicient : page will explain everything about the image
                 (available by March 17, 3097, or your money back)

        The result of this will be a QC_$subj directory (e.g., QC_FT),
        containing index.html, along with media_dat and media_img dirs.
        One should be able to view the QC information by opening index.html
        in a browser.

        These methods have different software requirements, but 'basic'
        was meant to have almost nothing, and should work on most systems.
        If insufficient software is available, afni_proc.py will
        (hopefully) not include this step.  Use 'none' to opt out.

    -keep_rm_files          : do not have script delete rm.* files at end

            e.g. -keep_rm_files

        The output script may generate temporary files in a block, which
        would be given names with prefix 'rm.'.  By default, those files
        are deleted at the end of the script.  This option blocks that
        deletion.

    -keep_script_on_err     : do not remove proc script if AP command fails

        When there is a fatal error in the afni_proc.py command, it will
        delete any incomplete proc script, unless this option is applied.

    -move_preproc_files     : move preprocessing files to preproc.data dir

        At the end of the output script, create a 'preproc.data' directory,
        and move most of the files there (dfile, outcount, pb*, rm*).

        See also -remove_preproc_files.

    -no_proc_command        : do not print afni_proc.py command in script

            e.g. -no_proc_command

        If this option is applied, the command used to generate the output
        script will be stored at the end of the script.

    -out_dir DIR            : specify the output directory for the script

            e.g. -out_dir ED_results
            default: SUBJ.results

        The AFNI processing script will create this directory and perform
        all processing in it.

    -outlier_count yes/no   : should we count outliers with 3dToutcount?

            e.g. -outlier_count no
            default: yes

        By default, outlier fractions are computed per TR with 3dToutcount.
        To disable outlier counting, apply this option with parameter 'no'.
        This is a yes/no option, meaning those are the only valid inputs.

        Note that -outlier_count must be 'yes' in order to censor outliers
        with -regress_censor_outliers.

        See "3dToutcount -help" for more details.
        See also -regress_censor_outliers.

    -outlier_legendre yes/no : use Legendre polynomials in 3dToutcount?

            e.g. -outlier_legendre no
            default: yes

        By default the -legendre option is passed to 3dToutcount.  Along
        with using better behaved polynomials, it also allows them to be
        higher than 3rd order (if desired).

        See "3dToutcount -help" for more details.

    -outlier_polort POLORT  : specify polynomial baseline for 3dToutcount

            e.g. -outlier_polort 3
            default: same degree that 3dDeconvolve would use:
                     1 + floor(run_length/150)

        Outlier counts come after detrending the data, where the degree
        of the polynomial trend defaults to the same that 3dDeconvolve
        would use.  This option will override the default.

        See "3dToutcount -help" for more details.
        See "3dDeconvolve -help" for more details.
        See also '-regress_polort' and '-outlier_legendre'.

    -radial_correlate yes/no : correlate each voxel with local radius

            e.g. -radial_correlate yes
            default: no

     ** Consider using -radial_correlate_blocks, instead.

        With this option set, @radial_correlate will be run on the
        initial EPI time series datasets.  That creates a 'corr_test'
        directory that one can review, plus potential warnings (in text)
        if large clusters of high correlations are found.

        (very abbreviated) method for @radial_correlate:
            for each voxel
               compute average time series within 20 mm radius sphere
               correlate central voxel time series with spherical average
            look for clusters of high correlations

        This is a useful quality control (QC) dataset that helps one find
        scanner artifacts, particularly including coils going bad.

        To visually check the results, the program text output suggests:

            run command: afni corr_test.results.postdata
            then set:    Underlay  = epi.SOMETHING
                         Overlay   = res.SOMETHING.corr
                         maybe threshold = 0.9, maybe clusterize

        See also -radial_correlate_blocks.
        See "@radial_correlate -help" for details and a list of options.

    -radial_correlate_blocks B0 B1 ... : specify blocks for correlations

            e.g. -radial_correlate_blocks tcat volreg
            e.g. -radial_correlate_blocks tcat volreg regress

        With this option set, @radial_correlate will be run at the end of
        each listed block.  It computes, for each voxel, the correlation
        with a local spherical average (def = 20mm radius).  By default,
        this uses a fast technique to compute an approximate average that
        is slightly Gaussian weighted (relative weight 0.84 at the radius)
        via 3dmerge, but far faster than a flat average via 3dLocalstat.

        Valid blocks include:

            tcat, tshift, volreg, blur, scale, regress

        The @radial_correlate command will produce an output directory of
        the form radcor.pbAA.BBBB, where 'AA' is the processing block index
        (e.g. 02), and BBBB is the block label (e.g. volreg).

        Those 'radcor.*' directories will contain one epi.ulay.rRUN dataset
        and a corresponding radcor.BLUR.rRUN.corr dataset for that run,
        e.g.,

            radcor.pb02.volreg/epi.ulay.r01+tlrc.BRIK
                               epi.ulay.r01+tlrc.HEAD
                               radcor.20.r01.corr+tlrc.BRIK
                               radcor.20.r01.corr+tlrc.HEAD

        For the regress block, radcor results will be generated for the
        all_runs and errts datasets.

        See also -radial_correlate_opts.
        See '@radial_correlate -help' for more details.

    -radial_correlate_opts OPTS...: specify options for @radial_correlate

            e.g. -radial_correlate_opts -corr_mask yes -merge_frad 0.25

        Use this to pass additional options to all @radial_correlate
        commands in the proc script.

        See also -radial_correlate_blocks.

    -reg_echo ECHO_NUM  : specify 1-based echo for registration

            e.g. -reg_echo 3
            default: 2

        Multi-echo data is registered based on a single echo, with the
        resulting transformations being applied to all echoes.  Use this
        option to specify the 1-based echo used to drive registration.

        Note that the echo used for driving registration should have
        reasonable tissue contrast.

    -remove_preproc_files   : delete pre-processed data

        At the end of the output script, delete the intermediate data (to
        save disk space).  Delete dfile*, outcount*, pb* and rm*.

        See also -move_preproc_files.

    -script SCRIPT_NAME     : specify the name of the resulting script

            e.g. -script ED.process.script
            default: proc_subj

        The output of this program is a script file.  This option can be
        used to specify the name of that file.

        See also -scr_overwrite, -subj_id.

    -scr_overwrite          : overwrite any existing script

            e.g. -scr_overwrite

        If the output script file already exists, it will be overwritten
        only if the user applies this option.

        See also -script.

    -sep_char CHAR          : apply as separation character in filenames

            e.g. -sep_char _
            default: .

        The separation character is used in many output filenames, such as
        the default '.' in:

            pb04.Nancy.r07.scale+orig.BRIK

        If (for some crazy reason) an underscore (_) character would be
        preferable, the result would be:

            pb04_Nancy_r07_scale+orig.BRIK

        If "-sep_char _" is applied, so is -subj_curly.

        See also -subj_curly.

    -subj_curly             : apply $subj as ${subj}

        The subject ID is used in dataset names is typically used without
        curly brackets (i.e. $subj).  If something is done where this would
        result in errors (e.g. "-sep_char _"), the curly brackets might be
        useful to delimit the variable (i.e. ${subj}).

        Note that this option is automatically applied in the case of
        "-sep_char _".

        See also -sep_char.

    -subj_id SUBJECT_ID     : specify the subject ID for the script

            e.g. -subj_id elvis
            default: SUBJ

        The subject ID is used in dataset names and in the output directory
        name (unless -out_dir is used).  This option allows the user to
        apply an appropriate naming convention.

    -test_for_dsets yes/no  : test for existence of input datasets

            e.g. -test_for_dsets no
            default: yes

        This options controls whether afni_proc.py check for the existence
        of input datasets.  In general, they must exist when afni_proc.py
        is run, in order to get run information (TR, #TRs, #runs, etc).

    -test_stim_files yes/no : evaluate stim_files for appropriateness?

            e.g. -test_stim_files no
            default: yes

        This options controls whether afni_proc.py evaluates the stim_files
        for validity.  By default, the program will do so.

        Input files are one of local stim_times, global stim_times or 1D
        formats.  Options -regress_stim_files and -regress_extra_stim_files
        imply 1D format for input files.  Otherwise, -regress_stim_times is
        assumed to imply local stim_times format (-regress_global_times
        implies global stim_times format).

        Checks include:

            1D              : # rows equals total reps
            local times     : # rows equal # runs
                            : times must be >= 0.0
                            : times per run (per row) are unique
                            : times cannot exceed run time
            global times    : file must be either 1 row or 1 column
                            : times must be >= 0.0
                            : times must be unique
                            : times cannot exceed total duration of all runs

        This option provides the ability to disable this test.

        See "1d_tool.py -help" for details on '-look_like_*' options.
        See also -regress_stim_files, -regress_extra_stim_files,
        -regress_stim_times, -regress_local_times, -regress_global_times.

    -verb LEVEL             : specify the verbosity of this script

            e.g. -verb 2
            default: 1

        Print out extra information during execution.

    -write_3dD_prefix PREFIX : specify prefix for outputs from 3dd_script

            e.g. -write_3dD_prefix basis.tent.
            default: test.

        If a separate 3dDeconvolve command script is generated via the
        option -write_3dD_script, then the given PREFIX will be used for
        relevant output files. in the script.

        See also -write_3dD_script.

    -write_3dD_script SCRIPT : specify SCRIPT only for 3dDeconvolve command

            e.g. -write_3dD_script run.3dd.tent

        This option is intended to be used with the EXACT same afni_proc.py
        command (aside from any -write_3dD_* options).  The purpose is to
        generate a corresponding 3dDeconvolve command script which could
        be run in the same results directory.

        Alternatively, little things could be changed that would only
        affect the 3dDeconvolve command in the new script, such as the
        basis function(s).

        The new script should include a prefix to distinguish output files
        from those created by the original proc script.

      * This option implies '-test_stim_files no'.

        See also -write_3dD_prefix, -test_stim_files.

    -write_ppi_3dD_scripts  : flag: write 3dD scripts for PPI analysis

            e.g. -write_ppi_3dD_scripts                        \
                 -regress_ppi_stim_files PPI_*.1D some_seed.1D \
                 -regress_ppi_stim_labels PPI_A PPI_B PPI_C seed

        Request 3dDeconvolve scripts for pre-PPI filtering (do regression
        without censoring) and post-PPI filtering (include PPI regressors
        and seed).

        This is a convenience method for creating extra 3dDeconvolve
        command scripts without having to run afni_proc.py multiple times
        with different options.

        Using this option, afni_proc.py will create the main proc script,
        plus :

           A. (if censoring was done) an uncensored 3dDeconvolve command
              pre-PPI filter script, to create an uncensored errts time
              series.

              This script is akin to using -write_3dD_* to output a
              regression script, along with adding -regress_skip_censor.
              The regression command should be identical to the original
              one, except for inclusion of 3dDeconvolve's -censor option.

           B. a 3dDeconvolve post-PPI filter script to include the PPI
              and seed regressors.

              This script is akin to using -write_3dD_* to output a
              regression script, along with passing the PPI and seed
              regressors via -regress_extra_stim_files and _labels.

        Use -regress_ppi_stim_files and -regress_ppi_stim_labels to
        specify the PPI (and seed) regressors and their labels.  These
        options are currently required.

        See also -regress_ppi_stim_files, -regress_ppi_stim_labels.

    -----------------------------------------------------------------
    Block options (in default block order) ~3~

    These options pertain to individual processing blocks.  Each option
    starts with the block name.

    -tcat_preSS_warn_limit LIMIT : TR #0 outlier limit to warn of pre-SS

            e.g. -tcat_preSS_warn_limit 0.7
            default: 0.4

        Outlier fractions are computed across TRs in the tcat processing
        block.  If TR #0 has a large fraction, it might suggest that pre-
        steady state TRs have been included in the analysis.  If the
        detected fraction exceeds this limit, a warning will be stored
        (and output by the @ss_review_basic script).

        The special case of limit = 0.0 implies no check will be done.

    -tcat_remove_first_trs NUM : specify how many TRs to remove from runs

            e.g. -tcat_remove_first_trs 3
            e.g. -tcat_remove_first_trs 3 1 0 0 3
            default: 0

        Since it takes several seconds for the magnetization to reach a
        steady state (at the beginning of each run), the initial TRs of
        each run may have values that are significantly greater than the
        later ones.  This option is used to specify how many TRs to
        remove from the beginning of every run.

        If the number needs to vary across runs, then one number should
        be specified per run.

    -tcat_remove_last_trs NUM : specify TRs to remove from run ends

            e.g. -tcat_remove_last_trs 10
            default: 0

        For when the user wants a simple way to shorten each run.

        See also -ricor_regs_rm_nlast.

    -despike_mask           : allow Automasking in 3dDespike

        By default, -nomask is applied to 3dDespike.  Since anatomical
        masks will probably not be contained within the Automask operation
        of 3dDespike (which uses methods akin to '3dAutomask -dilate 4'),
        it is left up to the user to speed up this operation via masking.

        Note that the only case in which this should be done is when
        applying the EPI mask to the regression.

        Please see '3dDespike -help' and '3dAutomask -help' for more
        information.

    -despike_new yes/no/... : set whether to use new version of 3dDespike

            e.g. -despike_new no
            e.g. -despike_new -NEW25
            default: yes

        Valid parameters: yes, no, -NEW, -NEW25

        Use this option to control whether to use one of the new versions.

        There is a '-NEW' option/method in 3dDespike which runs a faster
        method than the previous L1-norm method (Nov 2013).  The results
        are similar but not identical (different fits).  The difference in
        speed is more dramatic for long time series (> 500 time points).

        The -NEW25 option is meant to be more aggressive in despiking.

        Sep 2016: in 3dDespike, -NEW is now the default if the input is
                  longer than 500 time points.

        See also env var AFNI_3dDespike_NEW and '3dDespike -help' for more
        information.

    -despike_opts_3dDes OPTS... : specify additional options for 3dDespike

            e.g. -despike_opts_3dDes -nomask -ignore 2

        By default, 3dDespike is used with only -prefix and -nomask
        (unless -despike_mask is applied).  Any other options must be
        applied via -despike_opts_3dDes.

        Note that the despike block is not applied by default.  To apply
        despike in the processing script, use either '-do_block despike'
        or '-blocks ... despike ...'.

        Please see '3dDespike -help' for more information.
        See also '-do_blocks', '-blocks', '-despike_mask'.

    -ricor_datum DATUM      : specify output data type from ricor block

            e.g. -ricor_datum float

        By default, if the input is unscaled shorts, the output will be
        unscaled shorts.  Otherwise the output will be floats.

        The user may override this default with the -ricor_datum option.
        Currently only 'short' and 'float' are valid parameters.

        Note that 3dREMLfit only outputs floats at the moment.  Recall
        that the down-side of float data is that it takes twice the disk
        space, compared with shorts (scaled or unscaled).

        Please see '3dREMLfit -help' for more information.

    -ricor_polort POLORT    : set the polynomial degree for 3dREMLfit

            e.g. -ricor_polort 4
            default: 1 + floor(run_length / 75.0)

        The default polynomial degree to apply during the 'ricor' block is
        similar to that of the 'regress' block, but is based on twice the
        run length (and so should be almost twice as large).  This is to
        account for motion, since volreg has typically not happened yet.

        Use -ricor_polort to override the default.

    -ricor_regress_method METHOD    : process per-run or across-runs

            e.g. -ricor_regress_method across-runs
            default: NONE: this option is required for a 'ricor' block

        * valid METHOD parameters: per-run, across-runs

        The cardiac and respiratory signals can be regressed out of each
        run separately, or out of all runs at once.  The user must choose
        the method, there is no default.

        See "RETROICOR NOTE" for more details about the methods.

    -ricor_regress_solver METHOD    : regress using OLSQ or REML

            e.g. -ricor_regress_solver REML
            default: OLSQ

        * valid METHOD parameters: OLSQ, REML

        Use this option to specify the regression method for removing the
        cardiac and respiratory signals.  The default method is ordinary
        least squares, removing the "best fit" of the card/resp signals
        from the data (also subject to the polort baseline).

        To apply the REML (REstricted Maximum Likelihood) method, use this
        option.

        Note that 3dREMLfit is used for the regression in either case,
        particularly since the regressors are slice-based (they are
        different for each slice).

        Please see '3dREMLfit -help' for more information.

    -ricor_regs REG1 REG2 ...       : specify ricor regressors (1 per run)

            e.g. -ricor_regs slibase*.1D

        This option is required with a 'ricor' processing block.

        The expected format of the regressor files for RETROICOR processing
        is one file per run, where each file contains a set of regressors
        per slice.  If there are 5 runs and 27 slices, and if there are 13
        regressors per slice, then there should be 5 files input, each with
        351 (=27*13) columns.

        This format is based on the output of RetroTS.py, included in the
        AFNI distribution.

    -ricor_regs_nfirst NFIRST       : ignore the first regressor timepoints

            e.g. -ricor_regs_nfirst 2
            default: 0

        This option is similar to -tcat_remove_first_trs.  It is used to
        remove the first few TRs from the -ricor_regs regressor files.

        Since it is likely that the number of TRs in the ricor regressor
        files matches the number of TRs in the original input dataset (via
        the -dsets option), it is likely that -ricor_regs_nfirst should
        match -tcat_remove_first_trs.

        See also '-tcat_remove_first_trs', '-ricor_regs', '-dsets'.

    -ricor_regs_rm_nlast NUM : remove the last NUM TRs from each regressor

            e.g. -ricor_regs_rm_nlast 10
            default: 0

        For when the user wants a simple way to shorten each run.

        See also -tcat_remove_last_trs.

    -tshift_align_to TSHIFT OP : specify 3dTshift alignment option

            e.g. -tshift_align_to -slice 14
            default: -tzero 0

        By default, each time series is aligned to the beginning of the
        TR.  This option allows the users to change the alignment, and
        applies the option parameters directly to the 3dTshift command
        in the output script.

        It is likely that the user will use either '-slice SLICE_NUM' or
        '-tzero ZERO_TIME'.

        Note that when aligning to an offset other than the beginning of
        the TR, and when applying the -regress_stim_files option, then it
        may be necessary to also apply -regress_stim_times_offset, to
        offset timing for stimuli to later within each TR.

        Please see '3dTshift -help' for more information.
        See also '-regress_stim_times_offset'.

    -tshift_interp METHOD   : specify the interpolation method for tshift

            e.g. -tshift_interp -wsinc9
            e.g. -tshift_interp -Fourier
            e.g. -tshift_interp -cubic
            default -quintic

        Please see '3dTshift -help' for more information.

    -tshift_opts_ts OPTS ... : specify extra options for 3dTshift

            e.g. -tshift_opts_ts -tpattern alt+z

        This option allows the user to add extra options to the 3dTshift
        command.  Note that only one -tshift_opts_ts should be applied,
        which may be used for multiple 3dTshift options.

        Please see '3dTshift -help' for more information.

    -blip_forward_dset      : specify a forward blip dataset

            e.g. -blip_forward_dset epi_forward_blip+orig'[0..9]'

        Without this option, the first TRs of the first input EPI time
        series would be used as the forward blip dataset.

        See also -blip_revers_dset.

        Please see '3dQwarp -help' for more information, and the -plusminus
        option in particular.

    -blip_reverse_dset      : specify a reverse blip dataset

            e.g. -blip_reverse_dset epi_reverse_blip+orig
            e.g. -blip_reverse_dset epi_reverse_blip+orig'[0..9]'

        EPI distortion correction can be applied via blip up/blip down
        acquisitions.  Unless specified otherwise, the first TRs of the
        first run of typical EPI data specified via -dsets is considered
        to be the forward direction (blip up, say).  So only the reverse
        direction data needs separate input.

        Please see '3dQwarp -help' for more information, and the -plusminus
        option in particular.

    -blip_opts_qw OPTS ...  : specify extra options for 3dQwarp

            e.g. -blip_opts_qw -noXdis -noZdis

        This option allows the user to add extra options to the 3dQwarp
        command specific to the 'blip' processing block.

        There are many options (e.g. for blurring) applied in the 3dQwarp
        command by afni_proc.py by default, so review the resulting script.

        Please see '3dQwarp -help' for more information.

    -tlrc_anat              : run @auto_tlrc on '-copy_anat' dataset

            e.g. -tlrc_anat

        Run @auto_tlrc on the anatomical dataset provided by '-copy_anat'.
        By default, warp the anat to align with TT_N27+tlrc, unless the
        '-tlrc_base' option is given.

        The -copy_anat option specifies which anatomy to transform.

     ** Note, use of this option has the same effect as application of the
        'tlrc' block.

        Please see '@auto_tlrc -help' for more information.
        See also -copy_anat, -tlrc_base, -tlrc_no_ss and the 'tlrc' block.

    -tlrc_base BASE_DSET    : run "@auto_tlrc -base BASE_DSET"

            e.g. -tlrc_base TT_icbm452+tlrc
            default: -tlrc_base TT_N27+tlrc

        This option is used to supply an alternate -base dataset for
        @auto_tlrc (or auto_warp.py).  Otherwise, TT_N27+tlrc will be used.

        Note that the default operation of @auto_tlrc is to "skull strip"
        the input dataset.  If this is not appropriate, consider also the
        '-tlrc_no_ss' option.

        Please see '@auto_tlrc -help' for more information.
        See also -tlrc_anat, -tlrc_no_ss.

    -tlrc_copy_base yes/no  : copy base/template to results directory

            e.g. -tlrc_copy_base no
            default: -tlrc_copy_base yes

        By default, the template dataset (-tlrc_base) will be copied
        to the local results directory (for QC purposes).
        Use this option to override the default behavior.

        See also -tlrc_base.

    -tlrc_NL_warp           : use non-linear for template alignment

            e.g. -tlrc_NL_warp

        If this option is applied, then auto_warp.py is applied for the
        transformation to standard space, rather than @auto_tlrc, which in
        turn applies 3dQwarp (rather than 3dWarpDrive in @auto_tlrc).

        The output datasets from this operation are:

            INPUT_ANAT+tlrc         : standard space version of anat
            anat.un.aff.Xat.1D      : affine xform to standard space
            anat.un.aff.qw_WARP.nii : non-linear xform to standard space
                                      (displacement vectors across volume)

        The resulting ANAT dataset is copied out of the awpy directory
        back into AFNI format, and with the original name but new view,
        while the 2 transformation files (one text file of 12 numbers, one
        3-volume dataset vectors) are moved out with the original names.

        If -volreg_tlrc_warp is given, then the non-linear transformation
        will also be applied to the EPI data, sending the 'volreg' output
        directly to standard space.  As usual, all transformations are
        combined so that the EPI is only resampled one time.

        Options can be added to auto_warp.py via -tlrc_opts_at.

        Consider use of -anat_uniform_method along with this option.

        Please see 'auto_warp.py -help' for more information.
        See also -tlrc_opts_at, -anat_uniform_method.

    -tlrc_NL_warped_dsets ANAT WARP.1D NL_WARP: import auto_warp.py output

            e.g. -tlrc_NL_warped_dsets anat.nii           \
                                       anat.un.aff.Xat.1D \
                                       anat.un.aff.qw_WARP.nii

        If the user has already run auto_warp.py on the subject anatomy
        to transform (non-linear) to standard space, those datasets can
        be input to save re-processing time.

        They are the same 3 files that would be otherwise created by
        running auto_warp_py from the proc script.

        When using this option, the 'tlrc' block will be empty of actions.

    -tlrc_NL_force_view Y/N : force view when copying auto_warp.py result

            e.g.     -tlrc_NL_force_view no
            default: -tlrc_NL_force_view yes

        The auto_warp.py program writes results using NIFTI format.  If the
        alignment template is in a standard space that is not part of the
        NIFTI standard (TLRC and MNI are okay), then currently the only
        sform_code available is 2 ("aligned to something").  But that code
        is ambiguous, so users often set it to mean orig view (by setting
        AFNI_NIFTI_VIEW=orig).  This option (defaulting to yes) forces
        sform_code=2 to mean standard space, using +tlrc view.

    -tlrc_NL_awpy_rm Y/N    : specify whether to remove awpy directory

            e.g.     -tlrc_NL_awpy_rm no
            default: -tlrc_NL_awpy_rm yes

        The auto_warp.py program does all its work in an sub-directory
        called 'awpy', which is removed by default.  Use this option with
        'no' to save the awpy directory.

    -tlrc_no_ss             : add the -no_ss option to @auto_tlrc

            e.g. -tlrc_no_ss

        This option is used to tell @auto_tlrc not to perform the skull
        strip operation.

        Please see '@auto_tlrc -help' for more information.

    -tlrc_opts_at OPTS ...   : add additional options to @auto_tlrc

            e.g. -tlrc_opts_at -OK_maxite

        This option is used to add user-specified options to @auto_tlrc,
        specifically those afni_proc.py is not otherwise set to handle.

        In the case of -tlrc_NL_warp, the options will be passed to
        auto_warp.py, instead.

        Please see '@auto_tlrc -help' for more information.
        Please see 'auto_warp.py -help' for more information.

    -tlrc_rmode RMODE       : apply RMODE resampling in @auto_tlrc

            e.g. -tlrc_rmode NN

        This option is used to apply '-rmode RMODE' in @auto_tlrc.

        Please see '@auto_tlrc -help' for more information.

    -tlrc_suffix SUFFIX     : apply SUFFIX to result of @auto_tlrc

            e.g. -tlrc_suffix auto_tlrc

        This option is used to apply '-suffix SUFFIX' in @auto_tlrc.

        Please see '@auto_tlrc -help' for more information.

    -align_epi_ext_dset DSET : specify dset/brick for align_epi_anat EPI

            e.g. -align_epi_ext_dset subj10/epi_r01+orig'[0]'

        This option allows the user to specify an external volume for the
        EPI base used in align_epi_anat.py in the align block.  The user
        should apply sub-brick selection if the dataset has more than one
        volume.  This volume would be used for both the -epi and the
        -epi_base options in align_epi_anat.py.

        The user might want to align to an EPI volume that is not in the
        processing stream in the case where there is not sufficient EPI
        contrast left after the magnetization has reached a steady state.
        Perhaps volume 0 has sufficient contrast for alignment, but is not
        appropriate for analysis.  In such a case, the user may elect to
        align to volume 0, while excluding it from the analysis as part of
        the first volumes removed in -tcat_remove_first_trs.

        e.g. -dsets subj10/epi_r*_orig.HEAD
             -tcat_remove_first_trs 3
             -align_epi_ext_dset subj10/epi_r01+orig'[0]'
             -volreg_align_to first

        Note that even if the anatomy were acquired after the EPI, the user
        might still want to align the anat to the beginning of some run,
        and align all the EPIs to a time point close to that.  Since the
        anat and EPI are being forcibly aligned, it does not make such a
        big difference whether the EPI base is close in time to the anat
        acquisition.

        Note that this option does not affect the EPI registration base.

        Note that without this option, the volreg base dataset (whether
        one of the processed TRs or not) will be applied for anatomical
        alignment, assuming the align block is applied.

        See also -volreg_base_dset.
        Please see "align_epi_anat.py -help" for more information.

    -align_opts_aea OPTS ... : specify extra options for align_epi_anat.py

            e.g. -align_opts_aea -cost lpc+ZZ
            e.g. -align_opts_aea -cost lpc+ZZ -check_flip
            e.g. -align_opts_aea -Allineate_opts -source_automask+4
            e.g. -align_opts_aea -giant_move -AddEdge
            e.g. -align_opts_aea -skullstrip_opts -blur_fwhm 2

        This option allows the user to add extra options to the alignment
        command, align_epi_anat.py.

        Note that only one -align_opts_aea option should be given, with
        possibly many parameters to be passed on to align_epi_anat.py.

        Note the second example.  In order to pass '-source_automask+4' to
        3dAllineate, one must pass '-Allineate_opts -source_automask+4' to
        align_epi_anat.py.

        Similarly, the fourth example passes '-blur_fwhm 2' down through
        align_epi_anat.py to 3dSkullStrip.

      * The -check_flip option to align_epi_anat.py is good for evaluating
        data from external sources.  Aside from performing the typical
        registration, it will compare the final registration cost to that
        of a left/right flipped version.  If the flipped version is lower,
        one should investigate whether the axes are correctly labeled, or
        even labeled at all.

      * Please do not include -epi_strip with this -align_opts_aea option.
        That option to align_epi_anat.py should be controlled by
        -align_epi_strip_method.

        Please see "align_epi_anat.py -help" for more information.
        Please see "3dAllineate -help" for more information.

    -align_opts_eunif OPTS ... : add options to EPI uniformity command

            e.g. -align_opts_eunif -wdir_name work.epi_unif -no_clean

        This option allows the user to add extra options to the EPI
        uniformity correction command, probably 3dLocalUnifize (possibly
        3dUnifize).

        Please see "3dLocalUnifize -help" for more information.

    -align_epi_strip_method METHOD : specify EPI skull strip method in AEA

            e.g. -align_epi_strip_method 3dSkullStrip
            default: 3dAutomask (changed from 3dSkullStrip, 20 Aug, 2013)

        When align_epi_anat.py is used to align the EPI and anatomy, it
        uses 3dSkullStrip to remove non-brain tissue from the EPI dataset.
        However afni_proc.py changes that to 3dAutomask by default (as of
        August 20, 2013).  This option can be used to specify which method
        to use, one of 3dSkullStrip, 3dAutomask or None.

        This option assumes the 'align' processing block is used.

        Please see "align_epi_anat.py -help" for more information.
        Please see "3dSkullStrip -help" for more information.
        Please see "3dAutomask -help" for more information.

    -align_unifize_epi METHOD: run uniformity correction on EPI base volume

            e.g. -align_unifize_epi local
            default: no

        Use this option to run uniformity correction on the vr_base dataset
        for the purpose of alignment to the anat.

        The older yes/no METHOD choices were based on 3dUnifize.  The
        METHOD choices now include:

            local   : use 3dLocalUnifize ... (aka the "P Taylor special")
            unif    : use 3dUnifize -T2 ...
            yes     : (old choice) equivalent to unif
            no      : do not run EPI uniformity correction

        The uniformity corrected EPI volume is only used for anatomical
        alignment, and possibly visual quality control.

        One can use option -align_opts_eunif to pass extra options to
        either case (3dLocalUnifize or 3dUnifize).

        Please see "3dLocalUnifize -help" for more information.
        Please see "3dUnifize -help" for more information.

    -volreg_align_e2a       : align EPI to anatomy at volreg step

        This option is used to align the EPI data to match the anatomy.
        It is done by applying the inverse of the anatomy to EPI alignment
        matrix to the EPI data at the volreg step.  The 'align' processing
        block is required.

        At the 'align' block, the anatomy is aligned to the EPI data.
        When applying the '-volreg_align_e2a' option, the inverse of that
        a2e transformation (so now e2a) is instead applied to the EPI data.

        Note that this e2a transformation is catenated with the volume
        registration transformations, so that the EPI data is still only
        resampled the one time.  If the user requests -volreg_tlrc_warp,
        the +tlrc transformation will also be applied at that step in a
        single transformation.

        See also the 'align' block and '-volreg_tlrc_warp'.

    -volreg_align_to POSN   : specify the base position for volume reg

            e.g. -volreg_align_to last
            e.g. -volreg_align_to MIN_OUTLIER
            default: third

        This option takes 'first', 'third', 'last' or 'MIN_OUTLIER' as a
        parameter.  It specifies whether the EPI volumes are registered to
        the first or third volume (of the first run), the last volume (of
        the last run), or the volume that is consider a minimum outlier.
        The choice of 'first' or 'third' might correspond with when the
        anatomy was acquired before the EPI data.  The choice of 'last'
        might correspond to when the anatomy was acquired after the EPI
        data.

        The default of 'third' was chosen to go a little farther into the
        steady state data.

        Note that this is done after removing any volumes in the initial
        tcat operation.

      * A special case is if POSN is the string MIN_OUTLIER, in which
        case the volume with the minimum outlier fraction would be used.

        Since anat and EPI alignment tends to work very well, the choice
        of alignment base could even be independent of when the anatomy
        was acquired, making MIN_OUTLIER a good choice.

        Please see '3dvolreg -help' for more information.
        See also -tcat_remove_first_trs, -volreg_base_ind and
        -volreg_base_dset.

    -volreg_allin_auto_stuff OPT ...  : specify 'auto' options for 3dAllin.

            e.g. -volreg_allin_auto_stuff -autoweight -warp shift_rotate

        When using 3dAllineate to do EPI motion correction, the default
        'auto' options applied are:

            -automask -source_automask -autoweight
        
        Use this option to _replace_ them with whatever is preferable.

      * All 3 options will be replaced, so if -autoweight is still wanted,
        for example, please include it with -volreg_allin_auto_stuff.

        Please see '3dAllineate -help' for more details.

    -volreg_allin_cost COST : specify the cost function used in 3dAllineate

            e.g. -volreg_allin_cost lpa+zz

        When using 3dAllineate to do EPI motion correction, the default
        cost function is lpa.  Use this option to specify another.

        Please see '3dAllineate -help' for more details, including a list
        of cost functions.

    -volreg_post_vr_allin yes/no : do cross-run alignment of reg bases

            e.g. -volreg_post_vr_allin yes

        Using this option, time series registration will be done per run,
        with an additional cross-run registration of each within-run base
        to what would otherwise be the overall EPI registration base.

        3dAllineate is used for cross-run vr_base registration (to the
        global vr_base, say, which may or may not be one of the per-run
        vr_base datasets).

      * Consider use of -volreg_warp_dxyz, for cases when the voxel size
        might vary across runs.  It would ensure that the final grids are
        the same.

        See also -volreg_pvra_base_index, -volreg_warp_dxyz.

    -volreg_pvra_base_index INDEX : specify per run INDEX for post_vr_allin

            e.g.     -volreg_pvra_base_index 3
            e.g.     -volreg_pvra_base_index $
            e.g.     -volreg_pvra_base_index MIN_OUTLIER
            default: -volreg_pvra_base_index 0

        Use this option to specify the within-run volreg base for use with
        '-volreg_post_vr_allin yes'.  INDEX can be one of:

            0             : the default (the first time point per run)
            VAL           : an integer index, between 0 and the last
            $             : AFNI syntax to mean the last volume
            MIN_OUTLIER   : compute the MIN_OUTLIER per run, and use it

        See also -volreg_post_vr_allin.

    -volreg_base_dset DSET  : specify dset/sub-brick for volreg base

            e.g. -volreg_base_dset subj10/vreg_base+orig'[0]'
            e.g. -volreg_base_dset MIN_OUTLIER

        This option allows the user to specify an external dataset for the
        volreg base.  The user should apply sub-brick selection if the
        dataset has more than one volume.

        For example, one might align to a pre-magnetic steady state volume.

        Note that unless -align_epi_ext_dset is also applied, this volume
        will be used for anatomical to EPI alignment (assuming that is
        being done at all).

      * A special case is if DSET is the string MIN_OUTLIER, in which
        case the volume with the minimum outlier fraction would be used.

        See also -align_epi_ext_dset, -volreg_align_to and -volreg_base_ind.

    -volreg_base_ind RUN SUB : specify run/sub-brick indices for base

            e.g. -volreg_base_ind 10 123
            default: 0 0

        This option allows the user to specify exactly which dataset and
        sub-brick to use as the base registration image.  Note that the
        SUB index applies AFTER the removal of pre-steady state images.

      * The RUN number is 1-based, matching the run list in the output
        shell script.  The SUB index is 0-based, matching the sub-brick of
        EPI time series #RUN.  Yes, one is 1-based, the other is 0-based.
        Life is hard.

        The user can apply only one of the -volreg_align_to and
        -volreg_base_ind options.

        See also -volreg_align_to, -tcat_remove_first_trs and
        -volreg_base_dset.

    -volreg_get_allcostX yes/no : compute all anat/EPI costs

            e.g. -volreg_get_allcostX no
            default: yes

        By default, given the final anatomical dataset (anat_final) and
        the the final EPI volreg base (final_epi), this option can be used
        to compute alignment costs between the two volumes across all cost
        functions from 3dAllineate.  Effectively, it will add the following
        to the proc script:

            3dAllineate -base FINAL_EPI -input FINAL_ANAT -allcostX

        The text output is stored in the file out.allcostX.txt.

        This operation is informational only, to help evaluate alignment
        costs across subjects.

        Please see '3dAllineate -help' for more details.

    -volreg_compute_tsnr yes/no : compute TSNR datasets from volreg output

            e.g. -volreg_compute_tsnr yes
            default: no

        Use this option to compute a temporal signal to noise (TSNR)
        dataset at the end of the volreg block.  Both the signal and noise
        datasets are from the run 1 output, where the "signal" is the mean
        and the "noise" is the detrended time series.

        TSNR = average(signal) / stdev(noise)

        See also -regress_compute_tsnr.

    -volreg_interp METHOD   : specify the interpolation method for volreg

            e.g. -volreg_interp -quintic
            e.g. -volreg_interp -Fourier
            default: -cubic

        Please see '3dvolreg -help' for more information.

    -volreg_method METHOD   : specify method for EPI motion correction

            e.g. -volreg_method 3dAllineate
            default: 3dvolreg

        Use this option to specify which program should be run to perform
        EPI to EPI base motion correction over time.

        Please see '3dvolreg -help' for more information.

    -volreg_motsim          : generate motion simulated time series

        Use of this option will result in a 'motsim' (motion simulation)
        time series dataset that is akin to an EPI dataset altered only
        by motion and registration (no BOLD, no signal drift, etc).

        This dataset can be used to generate regressors of no interest to
        be used in the regression block.

        rcr - note relevant options once they are in

        Please see '@simulate_motion -help' for more information.

    -volreg_opts_ms OPTS ... : specify extra options for @simulate_motion

            e.g. -volreg_opts_ms -save_workdir

        This option can be used to pass extra options directly to the
        @simulate_motion command.

        See also -volreg_motsim.
        Please see '@simulate_motion -help' for more information.

    -volreg_opts_ewarp OPTS ... : specify extra options for EPI warp steps

            e.g. -volreg_opts_ewarp -short

        This option allows the user to add extra options to the commands
        used to apply combined transformations to EPI data, warping it to
        its final grid space (currently via either 3dAllineate or 
        3dNwarpApply).

        Please see '3dAllineate -help' for more information.
        Please see '3dNwarpApply -help' for more information.

    -volreg_opts_vr OPTS ... : specify extra options for 3dvolreg

            e.g. -volreg_opts_vr -twopass
            e.g. -volreg_opts_vr -noclip -nomaxdisp

        This option allows the user to add extra options to the 3dvolreg
        command.  Note that only one -volreg_opts_vr should be applied,
        which may be used for multiple 3dvolreg options.

        Please see '3dvolreg -help' for more information.

    -volreg_no_extent_mask  : do not create and apply extents mask

            default: apply extents mask

        This option says not to create or apply the extents mask.

        The extents mask:

        When EPI data is transformed to the anatomical grid in either orig
        or tlrc space (i.e. if -volreg_align_e2a or -volreg_tlrc_warp is
        applied), then the complete EPI volume will only cover part of the
        resulting volume space.  Worse than that, the coverage will vary
        over time, as motion will alter the final transformation (remember
        that volreg, EPI->anat and ->tlrc transformations are all combined,
        to prevent multiple resampling steps).  The result is that edge
        voxels will sometimes have valid data and sometimes not.

        The extents mask is made from an all-1 dataset that is warped with
        the same per-TR transformations as the EPI data.  The intersection
        of the result is the extents mask, so that every voxel in the
        extents mask has data at every time point.  Voxels that are not
        are missing data from some or all TRs.

        It is called the extents mask because it defines the 'bounding box'
        of valid EPI data.  It is not quite a tiled box though, as motion
        changes the location slightly, per TR.

        See also -volreg_align_e2a, -volreg_tlrc_warp.
        See also the 'extents' mask, in the "MASKING NOTE" section above.

    -volreg_regress_per_run : regress motion parameters from each run

        === This option has been replaced by -regress_motion_per_run. ===

    -volreg_tlrc_adwarp     : warp EPI to +tlrc space at end of volreg step

            default: stay in +orig space

        With this option, the EPI data will be warped to standard space
        (via adwarp) at the end of the volreg processing block.  Further
        processing through regression will be done in standard space.

        This option is useful for applying a manual Talairach transform,
        which does not work with -volreg_tlrc_warp.  To apply one from
        @auto_tlrc, -volreg_tlrc_warp is recommended.

        The resulting voxel grid is the minimum dimension, truncated to 3
        significant bits.  See -volreg_warp_dxyz for details.

        Note: this step requires a transformed anatomy, which can come from
        the -tlrc_anat option or from -copy_anat importing an existing one.

        Please see 'WARP TO TLRC NOTE' above, for additional details.
        See also -volreg_tlrc_warp, -volreg_warp_dxyz, -tlrc_anat,
        -copy_anat.

    -volreg_tlrc_warp       : warp EPI to +tlrc space at volreg step

            default: stay in +orig space

        With this option, the EPI data will be warped to standard space
        in the volreg processing block.  All further processing through
        regression will be done in standard space.

        Warping is done with volreg to apply both the volreg and tlrc
        transformations in a single step (so a single interpolation of the
        EPI data).  The volreg transformations (for each volume) are stored
        and multiplied by the +tlrc transformation, while the volume
        registered EPI data is promptly ignored.

        The volreg/tlrc (affine or non-linear) transformation is then
        applied as a single concatenated warp to the unregistered data.

        Note that the transformation concatenation is not possible when
        using the 12-piece manual transformation (see -volreg_tlrc_adwarp
        for details).

        The resulting voxel grid is the minimum dimension, truncated to 3
        significant bits.  See -volreg_warp_dxyz for details.

        Note: this step requires a transformed anatomy, which can come from
        the -tlrc_anat option or from -copy_anat importing an existing one.

        Please see 'WARP TO TLRC NOTE' above, for additional details.
        See also -volreg_tlrc_adwarp, -volreg_warp_dxyz, -tlrc_anat,
        -volreg_warp_master, -copy_anat.

    -volreg_warp_dxyz DXYZ  : grid dimensions for _align_e2a or _tlrc_warp

            e.g. -volreg_warp_dxyz 3.5
            default: min dim truncated to 3 significant bits
                     (see description, below)

        This option allows the user to specify the grid size for output
        datasets from the -volreg_tlrc_warp and -volreg_align_e2a options.
        In either case, the output grid will be isotropic voxels (cubes).

        By default, DXYZ is the minimum input dimension, truncated to
        3 significant bits (for integers, starts affecting them at 9, as
        9 requires 4 bits to represent).

        Some examples:
            ----------------------------  (integer range, so >= 4)
            8.00   ...  9.99   --> 8.0
            ...
            4.00   ...  4.99   --> 4.0
            ----------------------------  (3 significant bits)
            2.50   ...  2.99   --> 2.5
            2.00   ...  2.49   --> 2.0
            1.75   ...  1.99   --> 1.75
            1.50   ...  1.74   --> 1.5
            1.25   ...  1.49   --> 1.25
            1.00   ...  1.24   --> 1.0
            0.875  ...  0.99   --> 0.875
            0.75   ...  0.874  --> 0.75
            0.625  ...  0.74   --> 0.625
            0.50   ...  0.624  --> 0.50
            0.4375 ...  0.49   --> 0.4375
            0.375  ...  0.4374 --> 0.375
            ...

        Preferably, one can specify the new dimensions via -volreg_warp_master.

      * As of 2024.04.07: values just under a 3 bit limit will round up.
        The minimum dimension will first be scaled up by a factor of 1.0001
        before the truncation.  For example, 2.9998 will "round" up to 3.0,
        while 2.9997 will truncate down to 2.5.

        For a demonstration, try:

            afni_python_wrapper.py -eval 'test_truncation()'

        See also -volreg_warp_master.

    -volreg_warp_final_interp METHOD : set final interpolation method

            e.g. -volreg_warp_final_interp wsinc5
            default: none (use defaults of called programs)

        This option allows the user to specify the final interpolation
        method used when warping data or concatenating warps.  This applies
        to computation of a final/output volume, after any transformations
        are already known.  Examples include:

            - all combined non-NN warp cases, such as for the main EPI
              datasets from concatenated transformations
              (both affine and non-linear)
              (NN warps are where nearest neighbor is not automatic)
            - final EPI (warped vr base)
            - anatomical followers

        These options are currently applied via:

            3dAllineate -final
            3dNwarpApply -ainterp

        Common choices:

            NN          : nearest neighbor
            linear      : \
            cubic       : as stated, or "tri" versions, e.g. trilinear
                          (these apply to 3dAllineate and 3dNwarpApply)
            quintic     : /
          * wsinc5      : nice interpolation, less blur, sharper edges
                          ==> the likely use case

        Please see '3dAllineate -help' for more details.
        Please see '3dNwarpApply -help' for more details.

    -volreg_warp_master MASTER : master dataset for volreg warps

            e.g. -volreg_warp_master my_fave_grid+orig
            e.g. -volreg_warp_master my_fave_grid+tlrc
            default: anatomical grid at truncated voxel size
                     (if applicable)

        This option allows the user to specify a dataset grid to warp
        the registered EPI data onto.  The voxels need not be isotropic.

        One can apply -volreg_warp_dxyz in conjunction, to specify the
        master box, along with an isotropic voxel size.
        
        It is up to the user to be sure the MASTER grid is in a suitable
        location for the results.

        See also -volreg_warp_dxyz.

    -volreg_zpad N_SLICES   : specify number of slices for -zpad

            e.g. -volreg_zpad 4
            default: -volreg_zpad 1

        This option allows the user to specify the number of slices applied
        via the -zpad option to 3dvolreg.

    -surf_anat ANAT_DSET    : specify surface volume dataset

            e.g. -surf_anat SUMA/sb23_surf_SurfVol+orig

        This option is required in order to do surface-based analysis.

        This volumetric dataset should be the one used for generation of
        the surface (and therefore should be in perfect alignment).  It may
        be output by the surface generation software.

        Unless specified by the user, the processing script will register
        this anatomy with the current anatomy.

        Use -surf_anat_aligned if the surf_anat is already aligned with the
        current experiment.

        Use '-surf_anat_has_skull no' if the surf_anat has already been
        skull stripped.

        Please see '@SUMA_AlignToExperiment -help' for more details.
        See also -surf_anat_aligned, -surf_anat_has_skull.
        See example #8 for typical usage.

    -surf_spec spec1 [spec2]: specify surface specification file(s)

            e.g. -surf_spec SUMA/sb23_?h_141_std.spec

        Use this option to provide either 1 or 2 spec files for surface
        analysis.  Each file must have lh or rh in the name (to encode
        the hemisphere), and that can be their only difference.  So if
        the files do not have such a naming pattern, they should probably
        be copied to new files that do.  For example, consider the spec
        files included with the AFNI_data4 sample data:

            SUMA/sb23_lh_141_std.spec
            SUMA/sb23_rh_141_std.spec

    -surf_A surface_A       : specify first surface for mapping

            e.g. -surf_A smoothwm
            default: -surf_A smoothwm

        This option allows the user to specify the first (usually inner)
        surface for use when mapping from the volume and for blurring.
        If the option is not given, the smoothwm surface will be assumed.

    -surf_B surface_B       : specify second surface for mapping

            e.g. -surf_B pial
            default: -surf_B pial

        This option allows the user to specify the second (usually outer)
        surface for use when mapping from the volume (not for blurring).
        If the option is not given, the pial surface will be assumed.

    -surf_blur_fwhm FWHM    :  NO LONGER VALID

        Please use -blur_size, instead.

    -blur_filter FILTER     : specify 3dmerge filter option

            e.g. -blur_filter -1blur_rms
            default: -1blur_fwhm

        This option allows the user to specify the filter option from
        3dmerge.  Note that only the filter option is set here, not the
        filter size.  The two parts were separated so that users might
        generally worry only about the filter size.

        Please see '3dmerge -help' for more information.
        See also -blur_size.

    -blur_in_automask       : apply 3dBlurInMask -automask

        This option forces use of 3dBlurInMask -automask, regardless of
        whether other masks exist and are being applied.

        Note that one would not want to apply -automask via -blur_opts_BIM,
        as that might result in failure because of multiple -mask options.

        Note that -blur_in_automask implies '-blur_in_mask yes'.

        Please see '3dBlurInMask -help' for more information.
        See also -blur_in_mask, -blur_opts_BIM.

    -blur_in_mask yes/no    : specify whether to restrict blur to a mask

            e.g. -blur_in_mask yes
            default: no

        This option allows the user to specify whether to use 3dBlurInMask
        instead of 3dmerge for blurring.

        Note that the algorithms are a little different, and 3dmerge comes
        out a little more blurred.

        Note that 3dBlurInMask uses only FWHM kernel size units, so the
        -blur_filter should be either -1blur_fwhm or -FWHM.

        Please see '3dBlurInMask -help' for more information.
        Please see '3dmerge -help' for more information.
        See also -blur_filter.

    -blur_opts_BIM OPTS ...  : specify extra options for 3dBlurInMask

            e.g. -blur_opts_BIM -automask

        This option allows the user to add extra options to the 3dBlurInMask
        command.  Only one -blur_opts_BIM should be applied, which may be
        used for multiple 3dBlurInMask options.

        This option is only useful when '-blur_in_mask yes' is applied.

        Please see '3dBlurInMask -help' for more information.
        See also -blur_in_mask.

    -blur_opts_merge OPTS ... : specify extra options for 3dmerge

            e.g. -blur_opts_merge -2clip -20 50

        This option allows the user to add extra options to the 3dmerge
        command.  Note that only one -blur_opts_merge should be applied,
        which may be used for multiple 3dmerge options.

        Please see '3dmerge -help' for more information.

    -blur_size SIZE_MM      : specify the size, in millimeters

            e.g. -blur_size 6.0
            default: 4

        This option allows the user to specify the size of the blur used
        by 3dmerge (or another applied smoothing program).  It is applied
        as the 'bmm' parameter in the filter option (such as -1blur_fwhm)
        in 3dmerge.

        Note the relationship between blur sizes, as used in 3dmerge:

            sigma = 0.57735027 * rms = 0.42466090 * fwhm
            (implying fwhm = 1.359556 * rms)

        Programs 3dmerge and 3dBlurInMask apply -blur_size as an additional
        gaussian blur.  Therefore smoothing estimates should be computed
        per subject for the correction for multiple comparisons.

        Programs 3dBlurToFWHM and SurfSmooth apply -blur_size as the
        resulting blur, and so do not require blur estimation.

        Please see '3dmerge -help'      for more information.
        Please see '3dBlurInMask -help' for more information.
        Please see '3dBlurToFWHM -help' for more information.
        Please see 'SurfSmooth -help'   for more information.
        See also -blur_filter.

    -blur_to_fwhm           : blur TO the blur size (not add a blur size)

        This option changes the program used to blur the data.  Instead of
        using 3dmerge, this applies 3dBlurToFWHM.  So instead of adding a
        blur of size -blur_size (with 3dmerge), the data is blurred TO the
        FWHM of the -blur_size.

        Note that 3dBlurToFWHM should be run with a mask.  So either:
            o  put the 'mask' block before the 'blur' block, or
            o  use -blur_in_automask
        It is not appropriate to include non-brain in the blur estimate.

        Note that extra options can be added via -blur_opts_B2FW.

        Please see '3dBlurToFWHM -help' for more information.
        See also -blur_size, -blur_in_automask, -blur_opts_B2FW.

    -blur_opts_B2FW OPTS ... : specify extra options for 3dBlurToFWHM

            e.g. -blur_opts_B2FW -rate 0.2 -temper

        This allows the user to add extra options to the 3dBlurToFWHM
        command.  Note that only one -blur_opts_B2FW should be applied,
        which may be used for multiple 3dBlurToFWHM options.

        Please see '3dBlurToFWHM -help' for more information.

    -mask_apply TYPE        : specify which mask to apply in regression

            e.g. -mask_apply group

        If possible, masks will be made for the EPI data, the subject
        anatomy, the group anatomy and EPI warp extents.  This option is
        used to specify which of those masks to apply to the regression.
        One can specify a pre-defined TYPE, or a user-specified one that
        is defined via -anat_follower_ROI or -mask_import, for example.

           Valid pre-defined choices:  epi, anat, group, extents.
           Valid user-defined choices: mask LABELS specified elsewhere.

        A subject 'anat' mask will be created if the EPI anat anatomy are
        aligned, or if the EPI data is warped to standard space via the
        anat transformation.  In any case, a skull-stripped anat will exist.

        A 'group' anat mask will be created if the 'tlrc' block is used
        (via the -blocks or -tlrc_anat options).  In such a case, the anat
        template will be made into a binary mask.

        This option makes -regress_apply_mask obsolete.

        See "MASKING NOTE" and "DEFAULTS" for details.
        See also -blocks.
        See also -mask_import.

    -mask_dilate NUM_VOXELS : specify the automask dilation

            e.g. -mask_dilate 3
            default: 1

        By default, the masks generated from the EPI data are dilated by
        1 step (voxel), via the -dilate option in 3dAutomask.  With this
        option, the user may specify the dilation.  Valid integers must
        be at least zero.

        Note that 3dAutomask dilation is a little different from the
        natural voxel-neighbor dilation.

        Please see '3dAutomask -help' for more information.
        See also -mask_type.

    -mask_epi_anat yes/no : apply epi_anat mask in place of EPI mask

            e.g. -mask_epi_anat yes

        An EPI mask might be applied to the data either for simple
        computations (e.g. global brain correlation, GCOR), or actually
        applied to the EPI data.  The EPI mask $full_mask is used for most
        such computations, by default.

        The mask_epi_anat dataset is an intersection of full_mask and
        mask_anat, and might be better suited to such computations.

        Use this option to apply mask_epi_anat in place of full_mask.

    -mask_import LABEL MSET : import a final grid mask with the given label

            e.g. -mask_import Tvent template_ventricle_3mm+tlrc

        Use this option to import a mask that is aligned with the final
        EPI data _and_ is on the final grid.

            o  this might be based on the group template
            o  this should already be resampled appropriately
            o  no warping or resampling will be done to this dataset

        This mask can be applied via LABEL as other masks, using options
        like: -regress_ROI, -regress_ROI_PC, -regress_make_corr_vols,
              -regress_anaticor_label, -mask_intersect, -mask_union.

        For example, one might import a ventricle mask from the template,
        intersect it with the subject specific CSFe (eroded CSF) mask,
        and possibly take the union with WMe (eroded white matter), before
        using the result for principle component regression, as in:

            -mask_import Tvent template_ventricle_3mm+tlrc \
            -mask_intersect Svent CSFe Tvent               \
            -mask_union WM_vent Svent WMe                  \
            -regress_ROI_PC WM_vent 3                      \

        See also -regress_ROI, -regress_ROI_PC, -regress_make_corr_vols,
                 -regress_anaticor_label, -mask_intersect, -mask_union.

    -mask_intersect NEW_LABEL MASK_A MASK_B : intersect 2 masks

            e.g. -mask_intersect Svent CSFe Tvent

        Use this option to intersect 2 known masks to create a new mask.
        NEW_LABEL will be the label of the result, while MASK_A and MASK_B
        should be labels for existing masks.

        One could use this to intersect a template ventricle mask with each
        subject's specific CSFe (eroded CSF) mask from 3dSeg, for example.

        See -mask_import for more details.

    -mask_union NEW_LABEL MASK_A MASK_B : take union of 2 masks

            e.g. -mask_union WM_vent Svent WMe

        Use this option to take the union of 2 known masks to create a new
        mask.  NEW_LABEL will be the label of the result, while MASK_A and
        MASK_B should be labels for existing masks.

        One could use this to create union of CSFe and WMe for principle
        component regression, for example.

        See -mask_import for more details.

    -mask_opts_automask ... : specify extra options for 3dAutomask

            e.g. -mask_opts_automask -clfrac 0.2 -dilate 1

        This allows one to add extra options to the 3dAutomask command used
        to create a mask from the EPI data.

        Please see '3dAutomask -help' for more information.

    -mask_rm_segsy Y/N  : choose whether to delete the Segsy directory

            e.g. -mask_rm_segsy no
            default: yes

        This option is a companion to -mask_segment_anat.

        In the case of running 3dSeg to segment the anatomy, a resulting
        Segsy directory is created.  Since the main result is a Classes
        dataset, and to save disk space, the Segsy directory is removed
        by default.  Use this option to preserve it.

        See also -mask_segment_anat.

    -mask_segment_anat Y/N  : choose whether to segment anatomy

            e.g. -mask_segment_anat yes
            default: no (if anat_final is skull-stripped)

        This option controls whether 3dSeg is run to segment the anatomical
        dataset.  Such a segmentation would then be resampled to match the
        grid of the EPI data.

        When this is run, 3dSeg creates the Classes dataset, which is a
        composition mask of the GM/WM/CSF (gray matter, white matter and
        cerebral spinal fluid) regions.  Then 3dresample is used to create
        Classes_resam, the same mask but at the resolution of the EPI.

        Such a dataset might have multiple uses, such as tissue-based
        regression.  Note that for such a use, the ROI time series should
        come from the volreg data, before any blur.

      * Mask labels created by -mask_segment_anat and -mask_segment_erode
        can be applied with -regress_ROI and -regress_ROI_PC.

      * The CSF mask is of ALL CSF (not just in the ventricles), and is
        therefore not very appropriate to use with tissue-based regression.

        Consider use of -anat_uniform_method along with this option.

        Please see '3dSeg -help' for more information.
        Please see '3dUnifize -help' for more information.
        See also -mask_rm_segsy, -anat_uniform_method -mask_segment_erode,
         and -regress_ROI, -regress_ROI_PC.

    -mask_segment_erode Y/N

            e.g. -mask_segment_erode Yes
            default: yes (if -regress_ROI or -regress_anaticor)

        This option is a companion to -mask_segment_anat.

        Anatomical segmentation is used to create GM (gray matter), WM
        (white matter) and CSF masks.  When the _erode option is applied,
        eroded versions of those masks are created via 3dmask_tool.

        See also -mask_segment_anat, -regress_anaticor.
        Please see '3dmask_tool -help' for more information.

    -mask_test_overlap Y/N  : choose whether to test anat/EPI mask overlap

            e.g. -mask_test_overlap No
            default: Yes

        If the subject anatomy and EPI masks are computed, then the default
        operation is to run 3dABoverlap to evaluate the overlap between the
        two masks.  Output is saved in a text file.

        This option allows one to disable such functionality.

        Please see '3dABoverlap -help' for more information.

    -mask_type TYPE         : specify 'union' or 'intersection' mask type

            e.g. -mask_type intersection
            default: union

        This option is used to specify whether the mask applied to the
        analysis is the union of masks from each run, or the intersection.
        The only valid values for TYPE are 'union' and 'intersection'.

        This is not how to specify whether a mask is created, that is
        done via the 'mask' block with the '-blocks' option.

        Please see '3dAutomask -help', '3dMean -help' or '3dcalc -help'.
        See also -mask_dilate, -blocks.

    -combine_method METHOD  : specify method for combining echoes

            e.g. -combine_method OC
            default: OC

        When using the 'combine' block to combine echoes (for each run),
        this option can be used to specify the method used.  There are:

            - basic methods
            - methods using tedana.py (or similar) from Prantik
            - methods using tedana from the MEICA group


        ---- basic combine methods (that do not use any tedana) ----

            methods
            -------
            mean             : simple mean of echoes
            OC               : optimally combined (via @compute_OC_weights)
                               (current default is OC_A)
            OC_A             : original log(mean()) regression method
            OC_B             : newer log() time series regression method
                               (there is little difference between OC_A
                               and OC_B)

        ---- combine methods that use Prantik's "original" tedana.py ----

           Prantik's tedana.py is run using the 'tedana*' combine methods.

              Prantik's tedana.py requires python 2.7.

              By default, tedana.py will be applied from the AFNI
              installation directory.

              Alternatively, one can specify the location of a different
              tedana.py using -combine_tedana_path.  And if it is 
              preferable to run it as an executable (as opposed to running
              it via 'python PATH/TO/tedana.py'), one can tell this to
              tedana_wrapper.py by applying:
                     -combine_opts_tedwrap -tedana_is_exec

            methods
            -------
            OC_tedort        : OC, and pass tedana orts to regression
            tedana           : run tedana.py, using output dn_ts_OC.nii
            tedana_OC        : run tedana.py, using output ts_OC.nii
                               (i.e. use tedana.py for optimally combined)
            tedana_OC_tedort : tedana_OC, and include tedana orts


        ---- combine methods that use tedana from the MEICA group ----

           The MEICA group tedana is specified with 'm_tedana*' methods.

              This tedana requires python 3.6+.

              AFNI does not distribute this version of tedana, so it must
              be in the PATH.  For installation details, please see:

                 https://tedana.readthedocs.io/en/stable/installation.html

            methods
            -------
            m_tedana         : tedana from MEICA group (dn_ts_OC.nii.gz)
            m_tedana_OC      : tedana OC from MEICA group (ts_OC.nii.gz)
            m_tedana_m_tedort: tedana from MEICA group (dn_ts_OC.nii.gz)
                               "tedort" from MEICA group
                               (--tedort: "good" projected from "bad")


        The OC/OC_A combine method is from Posse et. al., 1999, and then
        applied by Kundu et. al., 2011 and presented by Javier in a 2017
        summer course.

        The 'tedort' methods for Prantik's tedana.py are applied using
        @extract_meica_ortvec, which projects the 'good' MEICA components
        out of the 'bad' ones, and saves those as regressors to be applied
        later.  Otherwise, some of the 'good' components are removed with
        the 'bad.  The tedort method can be applied with either AFNI OC or
        tedana OC (meaning the respective OC method would be applied to
        combine the echoes, and the tedort components will be passed on to
        the regress block).

        The 'm_tedanam_m_tedort' method for the MEICA group's passes
        option --tedort to 'tedana', and tedana does the "good" from "bad"
        projection before projecting the modified "bad" components from the
        time series.

        Please see '@compute_OC_weights -help' for more information.
        Please see '@extract_meica_ortvec -help' for more information.
        See also -combine_tedana_path.

    -combine_opts_tedana OPT OPT ... : specify extra options for tedana.py

            e.g. -combine_opts_tedana --sourceTEs=-1 --kdaw=10 --rdaw=1

        Use this option to pass extra options through to tedana.py.
        This applies to any tedana-based -combine_method.

        See also -combine_method.

    -combine_opts_tedwrap OPT OPT ... : pass options to tedana_wrapper.py

            e.g. -combine_opts_tedwrap -tedana_is_exec

        Use this option to pass extra options to tedana_wrapper.py.
        This applies to any tedana-based -combine_method.

    -combine_tedana_path PATH : specify path to tedana.py

            e.g. -combine_tedana_path ~/testbin/meica.libs/tedana.py
            default: from under afni binaries directory

        If one wishes to use a version of tedana.py other than what comes
        with AFNI, this option allows one to specify that file.

        This applies to any tedana-based -combine_method.

        See also -combine_method.

    -combine_tedort_reject_midk yes/no : reject midk components

            e.g. -combine_tedort_reject_midk no
            default: yes (matching original method)

        Is may not be clear whether the midk (mid-Kappa) components are
        good ones or bad.  If one is not so sure, it might make sense not
        to project them out.  To refrain from projecting them out, use
        this option with 'no' (the default is 'yes' to match the original
        method).

    -combine_tedana_save_all yes/no : save all ted wrapper preproc files

            e.g. -combine_tedana_save_all yes
            default: no (save only 3dZcat stacked dataset)

        Use the option to save all of the preprocessing files created by
        tedana_wrapper.py (when calling tedana.py).  The default is to save
        only the 3dZcat stacked dataset, which is then passed to tedana.py.

        Please see 'tedana_wrapper.py -help' for details.

    -scale_max_val MAX      : specify the maximum value for scaled data

            e.g. -scale_max_val 1000
            default 200

        The scale step multiples the time series for each voxel by a
        scalar so that the mean for that particular run is 100 (allowing
        interpretation of EPI values as a percentage of the mean).

        Values of 200 represent a 100% change above the mean, and so can
        probably be considered garbage (or the voxel can be considered
        non-brain).  The output values are limited so as not to sacrifice
        the precision of the values of short datasets.  Note that in a
        short (2-byte integer) dataset, a large range of values means
        bits of accuracy are lost for the representation.

        No max will be applied if MAX is <= 100.

        Please see 'DATASET TYPES' in the output of '3dcalc -help'.
        See also -scale_no_max.

    -scale_no_max           : do not apply a limit to the scaled values

        The default limit for scaled data is 200.  Use of this option will
        remove any limit from being applied.

        A limit on the scaled data is highly encouraged when working with
        'short' integer data, especially when not applying a mask.

        See also -scale_max_val.

    -regress_3dD_stop       : 3dDeconvolve should stop after X-matrix gen

        Use this option to tell 3dDeconvolve to stop after generating the
        X-matrix (via -x1D_stop).  This is useful if the user only wishes
        to run the regression through 3dREMLfit.

        See also -regress_reml_exec.

    -regress_anaticor       : generate errts using ANATICOR method

        Apply the ANATICOR method of HJ Jo, regressing out the WMeLocal
        time series, which varies across voxels.

        WMeLocal is the average time series from all voxels within 45 mm
        which are in the eroded white matter mask.

        The script will run the standard regression via 3dDeconvolve (or
        stop after setting up the X-matrix, if the user says to), and use
        that X-matrix, possibly censored, in 3dTproject.  The WMeLocal time
        series is applied along with the X-matrix to get the result.

        Note that other 4-D time series might be regressed out via the
        3dTproject step, as well.

        In the case of task-based ANATICOR, -regress_reml_exec is required,
        which uses 3dREMLfit to regress the voxel-wise ANATICOR regressors.

        This option implies -mask_segment_anat and -mask_segment_erode.

      * Consider use of -regress_anaticor_fast, instead.

        Please see "@ANATICOR -help" for more detail, including the paper
        reference for the method.
        See also -mask_segment_anat, -mask_segment_erode, -regress_3dD_stop.
        See also -regress_reml_exec.

    -regress_anaticor_label LABEL : specify LABEL for ANATICOR ROI

        To go with either -regress_anaticor or -regress_anaticor_fast,
        this option is used the specify an alternate label of an ROI
        mask to be used in the ANATICOR step.  The default LABEL is WMe
        (eroded white matter from 3dSeg).

        When this option is included, it is up to the user to make sure
        afni_proc.py has such a label, either by including options:
            -mask_segment_anat (and possibly -mask_segment_erode),
            -regress_ROI_PC, -regress_ROI, or -anat_follower_ROI.

        Any known label made via those options may be used.

        See also -mask_segment_anat, -mask_segment_erode, -regress_ROI_PC,
            -anat_follower_ROI.

    -regress_anaticor_radius RADIUS : specify RADIUS for local WM average

        To go with -regress_anaticor or -regress_anaticor_fast, use this
        option to specify the radius.  In the non-fast case that applies
        to spheres within which local white matter is averaged.  In the
        fast case, the radius is applied as the HWHM (half width at half
        max).  A small radius means the white matter is more local.

        If no white matter is found within the specified distance of some
        voxel, the effect is that ANATICOR will simply not happen at that
        voxel.  That is a reasonable "failure" case, in that it says there
        is simply no white matter close enough to regress out (again, at
        the given voxel).

        See also -regress_anaticor or -regress_anaticor_fast.

    -regress_anaticor_fast  : generate errts using fast ANATICOR method

        This applies basically the same method as with -regress_anaticor,
        above.  While -regress_anaticor creates WMeLocal dataset by
        getting the average white matter voxel within a fixed radius, the
        'fast' method computes it by instead integrating the white matter
        over a gaussian curve.

        There some basic effects of using the 'fast' method:

            1. Using a Gaussian curve to compute each voxel-wise regressor
               gives more weight to the white matter that is closest to
               each given voxel.  The FWHM of this 3D kernel is specified
               by -regress_anaticor_fwhm, with a default of 30 mm.

            2. If there is no close white matter (e.g. due to a poor
               segmentation), the Gaussian curve will likely find white
               matter far away, instead of creating an empty regressor.

            3. This is quite a bit faster, because it is done by creating
               a time series of all desired white matter voxels, blurring
               it, and then just regressing out that dataset.  The blur
               operation is much faster than a localstat one.

        Please see "@ANATICOR -help" for more detail, including the paper
        reference for the method.
        See also -regress_anaticor_fwhm/
        See also -mask_segment_anat, -mask_segment_erode, -regress_3dD_stop.
        See also -regress_anaticor.

    -regress_anaticor_fwhm FWHM  : specify FWHM for 'fast' ANATICOR, in mm

            e.g.     -regress_anaticor_fwhm 20
            default: -regress_anaticor_fwhm 30


     ** This option is no longer preferable.  The newer application of
        -regress_anaticor_fast "thinks" in terms of a radius, like HWHM.
        So consider -regress_anaticor_radius for all cases.


        This option applies to -regress_anaticor_fast.

        The 'fast' ANATICOR method blurs the time series of desired white
        matter voxels using a Gaussian kernel with the given FWHM (full
        width at half maximum).

        To understand the FWHM, note that it is essentially the diameter of
        a sphere where the contribution from points at that distance
        (FWHM/2) contribute half as much as the center point.  For example,
        if FWHM=10mm, then any voxel at a distance of 5 mm would contribute
        half as much as a voxel at the center of the kernel.

        See also -regress_anaticor_fast.

    -regress_anaticor_term_frac FRAC : specify termination fraction

            e.g.     -regress_anaticor_term_frac .25
            default: -regress_anaticor_term_frac .5

        In the typical case of -regress_anaticor_fast, to make it behave
        very similarly to -regress_anaticor, blurring is applied with a
        Gaussian kernel out to the radius specified by the user, say 30 mm.

        To make this kernel more flat, it is terminated at a fraction of
        the HWHM (half width at half max, say 0.5), while the blur radius
        is extended by the reciprocal (to keep the overall distance fixed).
        So that means blurring with a wider Gaussian kernel, but truncating
        it to stay fixed at the given radius.

        If the fraction were 1.0, the relative contribution at the radius
        would be 0.5 of the central voxel (by definition of FWHM/HWHM).
        At a fraction of 0.5 (default), the relative contribution is 0.84.
        At a fraction of 0.25, the relative contribution is 0.958, seen by:

           afni_util.py -print 'gaussian_at_hwhm_frac(.25)'

        Consider the default fraction of 0.5.  That means we want the
        "radius" of the blur to terminate at 0.5 * HWHM, making it more
        flat, such that the relative contribution at the edge is ~0.84.
        If the specified blur radius is 30 mm, that mean the HWHM should
        actually be 60 mm, and we stop computing at HWHM/2 = 30 mm.  Note
        that the blur in 3dmerge is applied not as a radius (HWHM), but as
        a diameter (FWHM), so these numbers are always then doubled.  In
        this example, it would use FWHM = 120 mm, to achieve a flattened
        30 mm radius Gaussian blur.

        In general, the HWHM widening (by 1/FRAC) makes the inner part of
        the kernel more flat, and then the truncation at FRAC*HWHM makes
        the blur computations still stop at the radius.  Clearly one can
        make a flatter curve with a smaller FRAC.

        To make the curve a "pure Gaussian", with no truncation, consider
        the option -regress_anaticor_full_gaussian.

        Please see "@radial_correlate -help" for more information.
        Please also see:
           afni_util.py -print 'gaussian_at_hwhm_frac.__doc__'
        See also -regress_anaticor_fast, -regress_anaticor_radius,
        -regress_anaticor_full_gaussian.

    -regress_anaticor_full_gaussian yes/no: use full Gaussian blur

            e.g.     -regress_anaticor_full_gaussian yes
            default: -regress_anaticor_full_gaussian no

        When using -regress_anaticor_fast to apply ANATICOR via a Gaussian
        blur, the blur kernel is extended and truncated to stop at the
        -regress_anaticor_radius HWHM of the Gaussian curve, allowing the
        shape to be arbitrarily close to the flat curve applied in the
        original ANATICOR method via -regress_anaticor.

        Use this option to prevent the truncation, so that a full Gaussian
        blur is applied at the specified HWHM radius (FWHM = 2*HWHM).

      * Note that prior to 22 May 2019, the full Gaussian was always
        applied with -regress_anaticor_fast.  This marks an actual change
        in processing.

        See also -regress_anaticor_fast, -regress_anaticor_radius.

    -regress_apply_mask     : apply the mask during scaling and regression

        By default, any created union mask is not applied to the analysis.
        Use this option to apply it.

     ** This option is essentially obsolete.  Please consider -mask_apply
        as a preferable option to choose which mask to apply.

        See "MASKING NOTE" and "DEFAULTS" for details.
        See also -blocks, -mask_apply.

    -regress_apply_mot_types TYPE1 ... : specify motion regressors

            e.g. -regress_apply_mot_types basic
            e.g. -regress_apply_mot_types deriv
            e.g. -regress_apply_mot_types demean deriv
            e.g. -regress_apply_mot_types none
            default: demean

        By default, the motion parameters from 3dvolreg are applied in the
        regression, but after first removing the mean, per run.  This is
        the application of the 'demean' regressors.

        This option gives the ability to choose a combination of:

            basic:  dfile_rall.1D - the parameters straight from 3dvolreg
                    (or an external motion file, see -regress_motion_file)
            demean: 'basic' params with the mean removed, per run
            deriv:  per-run derivative of 'basic' params (de-meaned)
            none:   do not regress any motion parameters
                    (but one can still censor)

     ** Note that basic and demean cannot both be used, as they would cause
        multi-collinearity with the constant drift parameters.

     ** Note also that basic and demean will give the same results, except
        for the betas of the constant drift parameters (and subject to
        computational precision).

     ** A small side effect of de-meaning motion parameters is that the
        constant drift terms should evaluate to the mean baseline.

        See also -regress_motion_file, -regress_no_motion_demean,
        -regress_no_motion_deriv, -regress_no_motion.

    -regress_apply_ricor yes/no : apply ricor regs in final regression

            e.g.     -regress_apply_ricor yes
            default: no

        This is from a change in the default behavior 30 Jan 2012.  Prior
        to then, the 13 (?) ricor regressors from slice 0 would be applied
        in the final regression (mostly accounting for degrees of freedom).
        But since resting state analysis relies on a subsequent correlation
        analysis, it seems cleaner not to regress them (a second time).

    -regress_bandpass lowf highf : bandpass the frequency range

            e.g.  -regress_bandpass 0.01 0.1

        This option is intended for use in resting state analysis.

        Use this option to perform bandpass filtering during the linear
        regression.  While such an operation is slow (much slower than the
        FFT using 3dBandpass), doing it during the regression allows one to
        perform (e.g. motion) censoring at the same time.

        This option has a similar effect to running 3dBandpass, e.g. the
        example of '-regress_bandpass 0.01 0.1' is akin to running:

            3dBandpass -ort motion.1D -band 0.01 0.1

        except that it is done in 3dDeconvolve using linear regression.
        And censoring is easy in the context of regression.

        Note that the Nyquist frequency is 0.5/TR.  That means that if the
        TR were >= 5 seconds, there would be no frequencies within the band
        range of 0.01 to 0.1 to filter.  So there is no point to such an
        operation.

        On the flip side, if the TR is 1.0 second or shorter, the range of
        0.01 to 0.1 would remove about 80% of the degrees of freedom (since
        everything above 0.1 is filtered/removed, up through 0.5).  This
        might result in a model that is overfit, where there are almost as
        many (or worse, more) regressors than time points to fit.

        So a 0.01 to 0.1 bandpass filter might make the most sense for a
        TR in [2.0, 3.0], or so.

        A different filter range would affect this, of course.

        See also -regress_censor_motion.

    -regress_basis BASIS    : specify the regression basis function

            e.g. -regress_basis 'BLOCK(4,1)'
            e.g. -regress_basis 'BLOCK(5)'
            e.g. -regress_basis 'TENT(0,14,8)'
            default: GAM

        This option is used to set the basis function used by 3dDeconvolve
        in the regression step.  This basis function will be applied to
        all user-supplied regressors (please let me know if there is need
        to apply different basis functions to different regressors).

     ** Note that use of dmBLOCK requires -stim_times_AM1 (or AM2).  So
        consider option -regress_stim_types.

     ** If using -regress_stim_types 'file' for a particular regressor,
        the basis function will be ignored.  In such a case, it is safest
        to use 'NONE' for the corresponding basis function.

        Please see '3dDeconvolve -help' for more information, or the link:
            https://afni.nimh.nih.gov/afni/doc/misc/3dDeconvolveSummer2004
        See also -regress_basis_normall, -regress_stim_times,
                 -regress_stim_types, -regress_basis_multi.

    -regress_basis_multi BASIS BASIS .. : specify multiple basis functions

            e.g. -regress_basis_multi 'BLOCK(30,1)' 'TENT(0,45,16)' \
                                      'BLOCK(30,1)' dmUBLOCK

        In the case that basis functions vary across stim classes, use
        this option to list a basis function for each class.  The given
        basis functions should correspond to the listed -regress_stim_times
        files, just as the -regress_stim_labels entries do.

        See also -regress_basis.

    -regress_basis_normall NORM : specify the magnitude of basis functions

            e.g. -regress_basis_normall 1.0

        This option is used to set the '-basis_normall' parameter in
        3dDeconvolve.  It specifies the height of each basis function.

        For the example basis functions, -basis_normall is not recommended.

        Please see '3dDeconvolve -help' for more information.
        See also -regress_basis.

    -regress_censor_extern CENSOR.1D : supply an external censor file

            e.g. -regress_censor_extern censor_bad_trs.1D

        This option is used to provide an initial censor file, if there
        is some censoring that is desired beyond the automated motion and
        outlier censoring.

        Any additional censoring (motion or outliers) will be combined.

         See also -regress_censor_motion, -regress_censor_outliers.

    -regress_censor_motion LIMIT : censor TRs with excessive motion

            e.g. -regress_censor_motion 0.3

        This option is used to censor TRs where the subject moved too much.
        "Too much" is decided by taking the derivative of the motion
        parameters (ignoring shifts between runs) and the sqrt(sum squares)
        per TR.  If this Euclidean Norm exceeds the given LIMIT, the TR
        will be censored.

        This option will result in the creation of 3 censor files:

            motion_$subj_censor.1D
            motion_$subj_CENSORTR.txt
            motion_$subj_enorm.1D

        motion_$subj_censor.1D is a 0/1 columnar file to be applied to
        3dDeconvolve via -censor.  A row with a 1 means to include that TR,
        while a 0 means to exclude (censor) it.

        motion_$subj_CENSORTR.txt is a short text file listing censored
        TRs, suitable for use with the -CENSORTR option in 3dDeconvolve.
        The -censor option is the one applied however, so this file is not
        used, but may be preferable for users to have a quick peek at.

        motion_$subj_enorm.1D is the time series that the LIMIT is applied
        to in deciding which TRs to censor.  It is the Euclidean norm of
        the derivatives of the motion parameters.  Plotting this will give
        users a visual indication of why TRs were censored.

        By default, the TR prior to the large motion derivative will also
        be censored.  To turn off that behavior, use -regress_censor_prev
        with parameter 'no'.

        If censoring the first few TRs from each run is also necessary,
        use -regress_censor_first_trs.

        Please see '1d_tool.py -help' for information on censoring motion.
        See also -regress_censor_prev and -regress_censor_first_trs.

    -regress_censor_first_trs N  : censor the first N TRs in each run

            e.g.     -regress_censor_first_trs 3
            default: N = 0

        If, for example, censoring the first 3 TRs per run is desired, a
        user might add "-CENSORTR '*:0-2'" to the -regress_opts_3dD option.
        However, when using -regress_censor_motion, these censoring options
        must be combined into one for 3dDeconvolve.

        The -regress_censor_first_trs censors those TRs along with any with
        large motion.

        See '-censor_first_trs' under '1d_tool.py -help' for details.
        See also '-regress_censor_motion'.

    -regress_censor_prev yes/no  : censor TRs preceding large motion

            default: -regress_censor_prev yes

        Since motion spans two TRs, the derivative is not quite enough
        information to decide whether it is more appropriate to censor
        the earlier or later TR.  To error on the safe side, many users
        choose to censor both.

        Use this option to specify whether to include the previous TR
        when censoring.

        By default this option is applied as 'yes'.  Users may elect not
        not to censor the previous TRs by setting this to 'no'.

        See also -regress_censor_motion.

    -regress_censor_outliers LIMIT : censor TRs with excessive outliers

            e.g. -regress_censor_outliers 0.15

        This option is used to censor TRs where too many voxels are flagged
        as outliers by 3dToutcount.  LIMIT should be in [0.0, 1.0], as it
        is a limit on the fraction of masked voxels.

        '3dToutcount -automask -fraction' is used to output the fraction of
        (auto)masked voxels that are considered outliers at each TR.  If
        the fraction of outlier voxels is greater than LIMIT for some TR,
        that TR is censored out.

        Depending on the scanner settings, early TRs might have somewhat
        higher intensities.  This could lead to the first few TRs of each
        run being censored.  To avoid censoring the first few TRs of each
        run, apply the -regress_skip_first_outliers option.

        Note that if motion is also being censored, the multiple censor
        files will be combined (multiplied) before 3dDeconvolve.

        See '3dToutcount -help' for more details.
        See also -regress_skip_first_outliers, -regress_censor_motion.

    -regress_compute_gcor yes/no : compute GCOR from unit errts

            e.g. -regress_compute_gcor no
            default: yes

        By default, the global correlation (GCOR) is computed from the
        masked residual time series (errts).

        GCOR can be thought of as the result of:
            A1. compute the correlations of each voxel with every other
                --> can be viewed as an NMASK x NMASK correlation matrix
            A2. compute GCOR: the average of the NMASK^2 values

        Since step A1 would take a lot of time and disk space, a more
        efficient computation is desirable:
            B0. compute USET: scale each voxel time series to unit length
            B1. compute GMU: the global mean of this unit dataset
            B2. compute a correlation volume (of each time series with GMU)
            B3. compute the average of this volume

        The actual computation is simplified even further, as steps B2 and
        B3 combine as the L2 norm of GMU.  The result is:
            B2'. length(GMU)^2  (or the sum of squares of GMU)

        The steps B0, B1 and B2' are performed in the proc script.

        Note: This measure of global correlation is a single number in the
              range [0, 1] (not in [-1, 1] as some might expect).

        Note: computation of GCOR requires a residual dataset, an EPI mask,
              and a volume analysis (no surface at the moment).

    -regress_compute_auto_tsnr_stats yes/no : compute auto TSNR stats

            e.g. -regress_compute_auto_tsnr_stats no
            default: yes

        By default, -regress_compute_tsnr_stats is applied with the 'brain'
        mask and the APQC_atlas dataset for the final space, if they exist
        and are appropriate.

        Use this option to prevent automatic computation of those TSNR stats.

        See also -regress_compute_tsnr, -regress_compute_tsnr_stats.

    -regress_compute_tsnr yes/no : compute TSNR dataset from errts

            e.g. -regress_compute_tsnr no
            default: yes

        By default, a temporal signal to noise (TSNR) dataset is created at
        the end of the regress block.  The "signal" is the all_runs dataset
        (input to 3dDeconvolve), and the "noise" is the errts dataset (the
        residuals from 3dDeconvolve).  TSNR is computed (per voxel) as the
        mean signal divided by the standard deviation of the noise.

           TSNR = average(signal) / stdev(noise)

        The main difference between the TSNR datasets from the volreg and
        regress blocks is that the data in the regress block has been
        smoothed and "completely" detrended (detrended according to the
        regression model: including polort, motion and stim responses).

        Use this option to prevent the TSNR dataset computation in the
        'regress' block.

        One can also compute per-ROI statistics over the resulting TSNR
        dataset via -regress_compute_tsnr_stats.

        See also -volreg_compute_tsnr.
        See also -regress_compute_tsnr_stats.

    -regress_compute_tsnr_stats ROI_DSET_LABEL ROI_1 ROI_2 ...
                              : compute TSNR statistics per ROI

            e.g. -regress_compute_tsnr_stats Glasser 4 41 99 999

            e.g. -anat_follower_ROI aeseg epi SUMA/aparc.a2009s+aseg.nii.gz \
                 -ROI_import Glasser ~/abin/MNI_Glasser_HCP_v1.0.nii.gz     \
                 -regress_compute_tsnr_stats aeseg   4 41 99 999            \
                 -regress_compute_tsnr_stats Glasser 4 41 99 999

            default: -regress_compute_tsnr_stats brain 1

        Given:
           - TSNR statistics are being computed in the regress block
           - there is an EPI-grid ROI dataset with label ROI_DSET_LABEL

        Then one can list ROI regions in each ROI dataset to compute TSNR
        statistics over.  Details will be output for each ROI region, such as
        quartiles of the TSNR values, and maximum depth coordinates.

        This option results in a compute_ROI_stats.tcsh command being run for
        the ROI and TSNR datasets, and the ROI indices of interest.

        ROI datasets (and their respective labels) are made via options like
        -anat_follower_ROI, -ROI_import or even -mask_segment_anat.

      * This option is currently automatically applied with a 'brain' ROI and
        the relevant APQC_atlas, if appropriate.  To override use of such an
        atlas, specify '-regress_compute_auto_tsnr_stats no'.

        See 'compute_ROI_stats.tcsh -help' for more details.
        See also -anat_follower_ROI, -ROI_import, -regress_compute_tsnr.

    -regress_mask_tsnr yes/no : apply mask to errts TSNR dataset

            e.g. -regress_mask_tsnr yes
            default: no

        By default, a temporal signal to noise (TSNR) dataset is created at
        the end of the regress block.  By default, this dataset is not
        masked (to match what is done in the regression).

        To mask, apply this option with 'yes'.

      * This dataset was originally masked, with the default changing to
        match the regression 22 Feb, 2021.

        See also -regress_compute_tsnr.

    -regress_fout yes/no         : output F-stat sub-bricks

            e.g. -regress_fout no
            default: yes

        This option controls whether to apply -fout in 3dDeconvolve.  The
        default is yes.

    -regress_make_cbucket yes/no : add a -cbucket option to 3dDeconvolve

            default: 'no'

        Recall that the -bucket dataset (no 'c') contains beta weights and
        various statistics, but generally not including baseline terms
        (polort and motion).

        The -cbucket dataset (with a 'c') is a little different in that it
        contains:
            - ONLY betas (no t-stats, no F-stats, no contrasts)
            - ALL betas (including baseline terms)
        So it has one volume (beta) per regressor in the X-matrix.

        The use is generally for 3dSynthesize, to recreate time series
        datasets akin to the fitts, but where the user can request any set
        of parameters to be included (for example, the polort and the main
        2 regressors of interest).

        Setting this to 'yes' will result in the -cbucket option being
        added to the 3dDeconvolve command.

        Please see '3dDeconvolve -help' for more details.

    -regress_make_corr_vols LABEL1 ... : create correlation volume dsets

            e.g. -regress_make_corr_vols aeseg FSvent
            default: one is made against full_mask

        This option is used to specify extra correlation volumes to compute
        based on the residuals (so generally for resting state analysis).

        What is a such a correlation volume?

           Given: errts     : the residuals from the linear regression
                  a mask    : to correlate over, e.g. full_mask == 'brain'

           Compute: for each voxel (in the errts, say), compute the correlation
              against the average over all voxels within the given mask.

         * This is a change (as of Jan, 2020).  This WAS a mean correlation
           (across masked voxels), but now it is a correlation of the mean
           (over masked voxels).

        The labels specified can be from any ROI mask, such as those coming
        via -anat_follower_ROI, -regress_ROI_PC, or from the automatic
        masks from -mask_segment_anat.

        See also -anat_follower_ROI, -regress_ROI_PC, -mask_segment_anat.

    -regress_mot_as_ort yes/no : regress motion parameters using -ortvec

            default: yes
            [default changed from 'no' to 'yes' 16 Jan, 2019]

        Applying this option with 'no', motion parameters would be passed
        to 3dDeconvolve using -stim_file and -stim_base, instead of the
        default -ortvec.

        Using -ortvec (the default) produces a "cleaner" 3dDeconvolve
        command, without the many extra -stim_file options.  Otherwise,
        all results should be the same.

    -regress_motion_per_run : regress motion parameters from each run

            default: regress motion parameters catenated across runs

        By default, motion parameters from the volreg block are catenated
        across all runs, providing 6 (assuming 3dvolreg) regressors of no
        interest in the regression block.

        With -regress_motion_per_run, the motion parameters from each run
        are used as separate regressors, providing a total of (6 * nruns)
        regressors.

        This allows for the magnitudes of the regressors to vary over each
        run, rather than using a single (best) magnitude over all runs.
        So more motion-correlated variance can be accounted for, at the
        cost of the extra degrees of freedom (6*(nruns-1)).

        This option will apply to all motion regressors, including
        derivatives (if requested).

        ** This option was previously called -volreg_regress_per_run. **

    -regress_skip_first_outliers NSKIP : ignore the first NSKIP TRs

            e.g. -regress_skip_first_outliers 4
            default: 0

        When using -regress_censor_outliers, any TR with too high of an
        outlier fraction will be censored.  But depending on the scanner
        settings, early TRs might have somewhat higher intensities, leading
        to them possibly being inappropriately censored.

        To avoid censoring any the first few TRs of each run, apply the
        -regress_skip_first_outliers option.

        See also -regress_censor_outliers.

    -regress_compute_fitts       : compute fitts via 3dcalc, not 3dDecon

        This option is to save memory during 3dDeconvolve, in the case
        where the user has requested both the fitts and errts datasets.

        Normally 3dDeconvolve is used to compute both the fitts and errts
        time series.  But if memory gets tight, it is worth noting that
        these datasets are redundant, one can be computed from the other
        (given the all_runs dataset).

            all_runs = fitts + errts

        Using -regress_compute_fitts, -fitts is no longer applied in 3dD
        (though -errts is).  Instead, note that an all_runs dataset is
        created just after 3dDeconvolve.  After that step, the script will
        create fitts as (all_runs-errts) using 3dcalc.

        Note that computation of both errts and fitts datasets is required
        for this option to be applied.

        See also -regress_est_blur_errts, -regress_errts_prefix,
        -regress_fitts_prefix and -regress_no_fitts.

    -regress_cormat_warnings Y/N : specify whether to get cormat warnings

            e.g. -mask_cormat_warnings no
            default: yes

        By default, '1d_tool.py -show_cormat_warnings' is run on the
        regression matrix.  Any large, pairwise correlations are shown
        in text output (which is also saved to a text file).

        This option allows one to disable such functionality.

        Please see '1d_tool.py -help' for more details.

    -regress_est_blur_detrend yes/no : use -detrend in blur estimation

            e.g. -regress_est_blur_detrend no
            default: yes

        This option specifies whether to apply the -detrend option when
        running 3dFWHMx to estimate the blur (auto correlation function)
        size/parameters.  It will apply to both epits and errts estimation.

        See also -regress_est_blur_epits, -regress_est_blur_errts.
        Please see '3dFWHMx -help' for more details.

    -regress_est_blur_epits      : estimate the smoothness of the EPI data

        This option specifies to run 3dFWHMx on each of the EPI datasets
        used for regression, the results of which are averaged.  These blur
        values are saved to the file blur_est.$subj.1D, along with any
        similar output from errts.

        These blur estimates may be input to 3dClustSim, for any multiple
        testing correction done for this subject.  If 3dClustSim is run at
        the group level, it is reasonable to average these estimates
        across all subjects (assuming they were scanned with the same
        protocol and at the same scanner).

        The mask block is required for this operation (without which the
        estimates are not reliable).

        Please see '3dFWHMx -help' for more information.
        See also -regress_est_blur_errts.

    -regress_est_blur_errts      : estimate the smoothness of the errts

        This option specifies to run 3dFWHMx on the errts dataset, output
        from the regression (by 3dDeconvolve).

        These blur estimates may be input to 3dClustSim, for any multiple
        testing correction done for this subject.  If 3dClustSim is run at
        the group level, it is reasonable to average these estimates
        across all subjects (assuming they were scanned with the same
        protocol and at the same scanner).

        Note that the errts blur estimates should be not only slightly
        more accurate than the epits blur estimates, but they should be
        slightly smaller, too (which is beneficial).

        The mask block is required for this operation (without which the
        estimates are not reliable).

        Please see '3dFWHMx -help' for more information.
        See also -regress_est_blur_epits.

    -regress_errts_prefix PREFIX : specify a prefix for the -errts option

            e.g. -regress_fitts_prefix errts

        This option is used to add a -errts option to 3dDeconvolve.  As
        with -regress_fitts_prefix, only the PREFIX is specified, to which
        the subject ID will be added.

        Please see '3dDeconvolve -help' for more information.
        See also -regress_fitts_prefix.

    -regress_fitts_prefix PREFIX : specify a prefix for the -fitts option

            e.g. -regress_fitts_prefix model_fit
            default: fitts

        By default, the 3dDeconvolve command in the script will be given
        a '-fitts fitts' option.  This option allows the user to change
        the prefix applied in the output script.

        The -regress_no_fitts option can be used to eliminate use of -fitts.

        Please see '3dDeconvolve -help' for more information.
        See also -regress_no_fitts.

    -regress_global_times        : specify -stim_times as global times

            default: 3dDeconvolve figures it out, if it can

        By default, the 3dDeconvolve determines whether -stim_times files
        are local or global times by the first line of the file.  If it
        contains at least 2 times (which include '*' characters), it is
        considered as local_times, otherwise as global_times.

        The -regress_global_times option is mostly added to be symmetric
        with -regress_local_times, as the only case where it would be
        needed is when there are other times in the first row, but the
        should still be viewed as global.

        See also -regress_local_times.

    -regress_local_times         : specify -stim_times as local times

            default: 3dDeconvolve figures it out, if it can

        By default, the 3dDeconvolve determines whether -stim_times files
        are local or global times by the first line of the file.  If it
        contains at least 2 times (which include '*' characters), it is
        considered as local_times, otherwise as global_times.

        In the case where the first run has only 1 stimulus (maybe even
        every run), the user would need to put an extra '*' after the
        first stimulus time.  If the first run has no stimuli, then two
        would be needed ('* *'), but only for the first run.

        Since this may get confusing, being explicit by adding this option
        is a reasonable thing to do.

        See also -regress_global_times.

    -regress_iresp_prefix PREFIX : specify a prefix for the -iresp option

            e.g. -regress_iresp_prefix model_fit
            default: iresp

        This option allows the user to change the -iresp prefix applied in
        the 3dDeconvolve command of the output script.

        By default, the 3dDeconvolve command in the script will be given a
        set of '-iresp iresp' options, one per stimulus type, unless the
        regression basis function is GAM.  In the case of GAM, the response
        form is assumed to be known, so there is no need for -iresp.

        The stimulus label will be appended to this prefix so that a sample
        3dDeconvolve option might look one of these 2 examples:

            -iresp 7 iresp_stim07
            -iresp 7 model_fit_donuts

        The -regress_no_iresp option can be used to eliminate use of -iresp.

        Please see '3dDeconvolve -help' for more information.
        See also -regress_no_iresp, -regress_basis.

    -regress_make_ideal_sum IDEAL.1D : create IDEAL.1D file from regressors

            e.g. -regress_make_ideal_sum ideal_all.1D

        By default, afni_proc.py will compute a 'sum_ideal.1D' file that
        is the sum of non-polort and non-motion regressors from the
        X-matrix.  This -regress_make_ideal_sum option is used to specify
        the output file for that sum (if sum_idea.1D is not desired).

        Note that if there is nothing in the X-matrix except for polort and
        motion regressors, or if 1d_tool.py cannot tell what is in there
        (if there is no header information), then all columns will be used.

        Computing the sum means adding a 1d_tool.py command to figure out
        which columns should be used in the sum (since mixing GAM, TENT,
        etc., makes it harder to tell up front), and a 3dTstat command to
        actually sum those columns of the 1D X-matrix (the X-matrix is
        output by 3dDeconvolve).

        Please see '3dDeconvolve -help', '1d_tool.py -help' and
        '3dTstat -help'.
        See also -regress_basis, -regress_no_ideal_sum.

    -regress_motion_file FILE.1D  : use FILE.1D for motion parameters

            e.g. -regress_motion_file motion.1D

        Particularly if the user performs motion correction outside of
        afni_proc.py, they may wish to specify a motion parameter file
        other than dfile_rall.1D (the default generated in the volreg
        block).

        Note: such files no longer need to be copied via -copy_files.

        If the motion file is in a remote directory, include the path,
        e.g. -regress_motion_file ../subject17/data/motion.1D .

    -regress_no_fitts       : do not supply -fitts to 3dDeconvolve

            e.g. -regress_no_fitts

        This option prevents the program from adding a -fitts option to
        the 3dDeconvolve command in the output script.

        See also -regress_fitts_prefix.

    -regress_no_ideal_sum      : do not create sum_ideal.1D from regressors

        By default, afni_proc.py will compute a 'sum_ideal.1D' file that
        is the sum of non-polort and non-motion regressors from the
        X-matrix.  This option prevents that step.

        See also -regress_make_ideal_sum.

    -regress_no_ideals      : do not generate ideal response curves

            e.g. -regress_no_ideals

        By default, if the GAM or BLOCK basis function is used, ideal
        response curve files are generated for each stimulus type (from
        the output X matrix using '3dDeconvolve -x1D').  The names of the
        ideal response function files look like 'ideal_LABEL.1D', for each
        stimulus label, LABEL.

        This option is used to suppress generation of those files.

        See also -regress_basis, -regress_stim_labels.

    -regress_no_iresp       : do not supply -iresp to 3dDeconvolve

            e.g. -regress_no_iresp

        This option prevents the program from adding a set of -iresp
        options to the 3dDeconvolve command in the output script.

        By default -iresp will be used unless the basis function is GAM.

        See also -regress_iresp_prefix, -regress_basis.

    -regress_no_mask        : do not apply the mask in regression

        ** This is now the default, making the option unnecessary.

        This option prevents the program from applying the mask dataset
        in the scaling or regression steps.

        If the user does not want to apply a mask in the regression
        analysis, but wants the full_mask dataset for other reasons
        (such as computing blur estimates), this option can be used.

        See also -regress_est_blur_epits, -regress_est_blur_errts.

    -regress_no_motion      : do not apply motion params in 3dDeconvolve

            e.g. -regress_no_motion

        This option prevents the program from adding the registration
        parameters (from volreg) to the 3dDeconvolve command, computing
        the enorm or censoring.

        ** To omit motion regression but to still compute the enorm and
            possibly censor, use:

                -regress_apply_mot_types none

    -regress_no_motion_demean : do not compute de-meaned motion parameters

            default: do compute them

        Even if they are not applied in the regression, the default is to
        compute de-meaned motion parameters.  These may give the user a
        better idea of motion regressors, since their scale will not be
        affected by jumps across run breaks or multi-run drift.

        This option prevents the program from even computing such motion
        parameters.  The only real reason to not do it is if there is some
        problem with the command.

    -regress_no_motion_deriv  : do not compute motion parameter derivatives

            default: do compute them

        Even if they are not applied in the regression, the default is to
        compute motion parameter derivatives (and de-mean them).  These can
        give the user a different idea about motion regressors, since the
        derivatives are a better indication of per-TR motion.  Note that
        the 'enorm' file that is created (and optionally used for motion
        censoring) is basically made by collapsing (via the Euclidean Norm
        - the square root of the sum of the squares) these 6 derivative
        columns into one.

        This option prevents the program from even computing such motion
        parameters.  The only real reason to not do it is if there is some
        problem with the command.

            See also -regress_censor_motion.

    -regress_no_stim_times  : do not use

        OBSOLETE: please see -regress_use_stim_files

    -regress_opts_fwhmx OPTS ... : specify extra options for 3dFWHMx

            e.g. -regress_opts_fwhmx -ShowMeClassicFWHM

        This option allows the user to add extra options to the 3dFWHMx
        commands used to get blur estimates.  Note that only one
        such option should be applied, though multiple parameters
        (3dFWHMx options) can be passed.

        Please see '3dFWHMx -help' for more information.

    -regress_opts_3dD OPTS ...   : specify extra options for 3dDeconvolve

            e.g. -regress_opts_3dD -gltsym ../contr/contrast1.txt  \
                                   -glt_label 1 FACEvsDONUT        \
                                   -jobs 6                         \
                                   -GOFORIT 8

        This option allows the user to add extra options to the 3dDeconvolve
        command.  Note that only one -regress_opts_3dD should be applied,
        which may be used for multiple 3dDeconvolve options.

        Please see '3dDeconvolve -help' for more information, or the link:
            https://afni.nimh.nih.gov/afni/doc/misc/3dDeconvolveSummer2004

    -regress_opts_reml OPTS ...  : specify extra options for 3dREMLfit

            e.g. -regress_opts_reml                                 \
                    -gltsym ../contr/contrast1.txt FACEvsDONUT      \
                    -MAXa 0.92

        This option allows the user to add extra options to the 3dREMLfit
        command.  Note that only one -regress_opts_reml should be applied,
        which may be used for multiple 3dREMLfit options.

        Please see '3dREMLfit -help' for more information.

    -regress_ppi_stim_files FILE FILE ... : specify PPI (and seed) files

            e.g. -regress_ppi_stim_files PPI.1.A.1D PPI.2.B.1D PPI.3.seed.1D

        Use this option to pass PPI stimulus files for inclusion in
        3dDeconvolve command.  This list is essentially appended to
        (and could be replaced by) -regress_extra_stim_files.

      * These are not timing files, but direct regressors.

        Use -regress_ppi_stim_labels to specify the corresponding labels.

        See also -write_ppi_3dD_scripts, -regress_ppi_stim_labels.

    -regress_ppi_stim_labels LAB1 LAB2 ... : specify PPI (and seed) labels

            e.g. -regress_ppi_stim_files PPI.taskA PPI.taskB PPI.seed

        Use this option to specify labels for the PPI stimulus files
        specified via -regress_ppi_stim_files.  This list is essentially
        appended to (and could be replaced by) -regress_extra_stim_labels.

        Use -regress_ppi_stim_labels to specify the corresponding labels.

        See also -write_ppi_3dD_scripts, -regress_ppi_stim_labels.

    -regress_polort DEGREE  : specify the polynomial degree of baseline

            e.g. -regress_polort 2
            default: 1 + floor(run_length / 150.0)

        3dDeconvolve models the baseline for each run separately, using
        Legendre polynomials (by default).  This option specifies the
        degree of polynomial.  Note that this will create DEGREE * NRUNS
        regressors.

        The default is computed from the length of a run, in seconds, as
        shown above.  For example, if each run were 320 seconds, then the
        default polort would be 3 (cubic).

      * It is also possible to use a high-pass filter to model baseline
        drift (using sinusoids).  Since sinusoids do not model quadratic
        drift well, one could consider using both, as in:

            -regress_polort 2         \
            -regress_bandpass 0.01 1

        Here, the sinusoids allow every frequency from 0.01 on up to pass
        (assuming the Nyquist frequency is <= 1), modeling the lower
        frequencies as regressors of no interest, along with 3 terms for
        polort 2.

        Please see '3dDeconvolve -help' for more information.

    -regress_reml_exec      : execute 3dREMLfit, matching 3dDeconvolve cmd

        3dDeconvolve automatically creates a 3dREMLfit command script to
        match the regression model of 3dDeconvolve.  Via this option, the
        user can have that command executed.

        Note that the X-matrix used in 3dREMLfit is actually generated by
        3dDeconvolve.  The 3dDeconvolve command generates both the X-matrix
        and the 3dREMLfit command script, and so it must be run regardless
        of whether it actually performs the regression.

        To terminate 3dDeconvolve after creation of the X-matrix and
        3dREMLfit command script, apply -regress_3dD_stop.

        See also -regress_3dD_stop.

    -regress_ROI R1 R2 ... : specify a list of mask averages to regress out

            e.g. -regress_ROI WMe
            e.g. -regress_ROI brain WMe CSF
            e.g. -regress_ROI FSvent FSwhite

        Use this option to regress out one more more known ROI averages.
        ROIs that can be generated from -mask_segment_anat/_erode include:

            name    description     source dataset    creation program
            -----   --------------  --------------    ----------------
            brain   EPI brain mask  full_mask         3dAutomask
                       or, if made: mask_epi_anat     3dAutomask/3dSkullStrip
            CSF     CSF             mask_CSF_resam    3dSeg -> Classes
            CSFe    CSF (eroded)    mask_CSFe_resam   3dSeg -> Classes
            GM      gray matter     mask_GM_resam     3dSeg -> Classes
            GMe     gray (eroded)   mask_GMe_resam    3dSeg -> Classes
            WM      white matter    mask_WM_resam     3dSeg -> Classes
            WMe     white (eroded)  mask_WMe_resam    3dSeg -> Classes

        Other ROI labels can come from -anat_follower_ROI options, i.e.
        imported masks.

      * Use of this option requires either -mask_segment_anat or labels
        defined via -anat_follower_ROI options.

        See also -mask_segment_anat/_erode, -anat_follower_ROI.
        Please see '3dSeg -help' for more information on the masks.

    -regress_ROI_PC LABEL NUM_PC    : regress out PCs within mask

            e.g. -regress_ROI_PC vent 3
                 -regress_ROI_PC WMe 3

        Add the top principal components (PCs) over an anatomical mask as
        regressors of no interest.

          - LABEL   : the class label given to this set of regressors
          - NUM_PC  : the number of principal components to include

        The LABEL can apply to something defined via -mask_segment_anat
        maybe with -mask_segment_erode, or from -anat_follower_ROI
        (assuming 'epi' grid), or 'brain' (full_mask).  The -mask_segment*
        options define ROI labels implicitly (see above), while the user
        defines ROI labels in any -anat_follower_ROI options.

        Method (including 'follower' steps):

          If -anat_follower_ROI is used to define the label, then the
          follower ROI steps would first be applied to that dataset.

          If ROIs are created 'automatically' via 3dSeg (-mask_segment_anat)
          then the follower steps do not apply.

          F1. if requested (-anat_follower_erode) erode the ROI mask
          F2. apply all anatomical transformations to the ROI mask
              a. catenate all anatomical transformations
                 i.   anat to EPI?
                 ii.  affine xform of anat to template?
                 iii. subsequent non-linear xform of anat to template?
              b. sample the transformed mask on the EPI grid
              c. use nearest neighbor interpolation, NN

       Method (post-mask alignment):

          P1. extract the top NUM_PC principal components from the volume
              registered EPI data, over the mask
              a. detrend the volume registered EPI data at the polort level
                 to be used in the regression, per run
              b. catenate the detrended volreg data across runs
              c. compute the top PCs from the (censored?) time series
              d. if censoring, zero-fill the time series with volumes of
                 zeros at the censored TRs, to maintain TR correspondence
          P2. include those PCs as regressors of no interest
              a. apply with: 3dDeconvolve -ortvec PCs LABEL

        Typical usage might start with the FreeSurfer parcellation of the
        subject's anatomical dataset, followed by ROI extraction using
        3dcalc (to make a new dataset of just the desired regions).  Then
        choose the number of components to extract and a label.

        That ROI dataset, PC count and label are then applied with this
        option.

      * The given MASK must be in register with the anatomical dataset,
        though it does not necessarily need to be on the anatomical grid.

      * Multiple -regress_ROI_PC options can be used.

        See also -anat_follower, -anat_follower_ROI, -regress_ROI_erode,
        and -regress_ROI.

    -regress_ROI_per_run LABEL ... : regress these ROIs per run

            e.g. -regress_ROI_per_run vent
            e.g. -regress_ROI_per_run vent WMe

        Use this option to create the given ROI regressors per run.
        Instead of creating one regressor spanning all runs, this option
        leads to creating one regressor per run, akin to splitting the
        long regressor across runs, and zero-padding to be the same length.

        See also -regress_ROI_PC, -regress_ROI_PC_per_run.

    -regress_ROI_PC_per_run LABEL ... : regress these PCs per run

            e.g. -regress_ROI_PC_per_run vent
            e.g. -regress_ROI_PC_per_run vent WMe

        Use this option to create the given PC regressors per run.  So
        if there are 4 runs and 3 'vent' PCs were requested with the
        option "-regress_ROI_PC vent 3", then applying this option with
        the 'vent' label results in not 3 regressors (one per PC), but
        12 regressors (one per PC per run).

        Note that unlike the -regress_ROI_per_run case, this is not merely
        splitting one signal across runs.  In this case the principle
        components are be computed per run, almost certainly resulting in
        different components than those computed across all runs at once.

        See also -regress_ROI_PC, -regress_ROI_per_run.

    -regress_RSFC           : perform bandpassing via 3dRSFC

        Use this option flag to run 3dRSFC after the linear regression
        step (presumably to clean resting state data).  Along with the
        bandpassed data, 3dRSFC will produce connectivity parameters,
        saved in the RSFC directory by the proc script.

        The -regress_bandpass option is required, and those bands will be
        passed directly to 3dRSFC.  Since bandpassing will be done only
        after the linear regression, censoring is not advisable.

        See also -regress_bandpass, -regress_censor_motion.
        Please see '3dRSFC -help' for more information.

    -regress_RONI IND1 ...  : specify a list of regressors of no interest

            e.g. -regress_RONI 1 17 22

        Use this option flag regressors as ones of no interest, meaning
        they are applied to the baseline (for full-F) and the corresponding
        beta weights are not output (by default at least).

        The indices in the list should match those given to 3dDeconvolve.
        They start at 1 first with the main regressors, and then with any
        extra regressors (given via -regress_extra_stim_files).  Note that
        these do not apply to motion regressors.

        The user is encouraged to check the 3dDeconvolve command in the
        processing script, to be sure they are applied correctly.

    -regress_show_df_info yes/no    : set whether to report DoF information

            e.g.     -regress_show_df_info no
            default: -regress_show_df_info yes

        This option is used to specify whether get QC information about
        degrees of freedom using:

            1d_tool.py -show_df_info

        By default, that will be run, saving output to out.df_info.txt.

        Please see '1d_tool.py -help' for more information.

    -regress_stim_labels LAB1 ...   : specify labels for stimulus classes

            e.g. -regress_stim_labels houses faces donuts
            default: stim01 stim02 stim03 ...

        This option is used to apply a label to each stimulus type.  The
        number of labels should equal the number of files used in the
        -regress_stim_times option, or the total number of columns in the
        files used in the -regress_stim_files option.

        These labels will be applied as '-stim_label' in 3dDeconvolve.

        Please see '3dDeconvolve -help' for more information.
        See also -regress_stim_times, -regress_stim_labels.

    -regress_stim_times FILE1 ... : specify files used for -stim_times

            e.g. -regress_stim_times ED_stim_times*.1D
            e.g. -regress_stim_times times_A.1D times_B.1D times_C.1D

        3dDeconvolve will be run using '-stim_times'.  This option is
        used to specify the stimulus timing files to be applied, one
        file per stimulus type.  The order of the files given on the
        command line will be the order given to 3dDeconvolve.  Each of
        these timing files will be given along with the basis function
        specified by '-regress_basis'.

        The user must specify either -regress_stim_times or
        -regress_stim_files if regression is performed, but not both.
        Note the form of the files is one row per run.  If there is at
        most one stimulus per run, please add a trailing '*'.

        Labels may be specified using the -regress_stim_labels option.

        These two examples of such files are for a 3-run experiment.  In
        the second example, there is only 1 stimulus at all, occurring in
        run #2.

            e.g.            0  12.4  27.3  29
                            *
                            30 40 50

            e.g.            *
                            20 *
                            *

        Please see '3dDeconvolve -help' for more information, or the link:
            https://afni.nimh.nih.gov/afni/doc/misc/3dDeconvolveSummer2004
        See also -regress_stim_files, -regress_stim_labels, -regress_basis,
                 -regress_basis_normall, -regress_polort.

    -regress_stim_files FILE1 ... : specify TR-locked stim files

            e.g. -regress_stim_files ED_stim_file*.1D
            e.g. -regress_stim_files stim_A.1D stim_B.1D stim_C.1D

        Without the -regress_use_stim_files option, 3dDeconvolve will be
        run using '-stim_times', not '-stim_file'.  The user can still
        specify the 3dDeconvolve -stim_file files here, but they would
        then be converted to -stim_times files using the script,
        make_stim_times.py .

        It might be more educational for the user to run make_stim_times.py
        outside afni_proc.py (such as was done before example 2, above), or
        to create the timing files directly.

        Each given file can be for multiple stimulus classes, where one
        column is for one stim class, and each row represents a TR.  So
        each file should have NUM_RUNS * NUM_TRS rows.

        The stim_times files will be labeled stim_times.NN.1D, where NN
        is the stimulus index.

        Note that if the stimuli were presented at a fixed time after
        the beginning of a TR, the user should consider the option,
        -regress_stim_times_offset, to apply that offset.

        ---

        If the -regress_use_stim_files option is provided, 3dDeconvolve
        will be run using each stim_file as a regressor.  The order of the
        regressors should match the order of any labels, provided via the
        -regress_stim_labels option.

        Alternately, this can be done via -regress_stim_times, along
        with -regress_stim_types 'file'.

        Please see '3dDeconvolve -help' for more information, or the link:
            https://afni.nimh.nih.gov/afni/doc/misc/3dDeconvolveSummer2004
        See also -regress_stim_times, -regress_stim_labels, -regress_basis,
                 -regress_basis_normall, -regress_polort,
                 -regress_stim_times_offset, -regress_use_stim_files.

    -regress_extra_stim_files FILE1 ... : specify extra stim files

            e.g. -regress_extra_stim_files resp.1D cardiac.1D
            e.g. -regress_extra_stim_files regs_of_no_int_*.1D

        Use this option to specify extra files to be applied with the
        -stim_file option in 3dDeconvolve (as opposed to the more usual
        option, -stim_times).

        These files will not be converted to stim_times format.

        Corresponding labels can be given with -regress_extra_stim_labels.

        See also -regress_extra_stim_labels, -regress_ROI, -regress_RONI.

    -regress_extra_stim_labels LAB1 ... : specify extra stim file labels

            e.g. -regress_extra_stim_labels resp cardiac

        If -regress_extra_stim_files is given, the user may want to specify
        labels for those extra stimulus files.  This option provides that
        mechanism.  If this option is not given, default labels will be
        assigned (like stim17, for example).

        Note that the number of entries in this list should match the
        number of extra stim files.

        See also -regress_extra_stim_files.

    -regress_stim_times_offset OFFSET : add OFFSET to -stim_times files

            e.g. -regress_stim_times_offset 1.25
            e.g. -regress_stim_times_offset -9.2
            default: 0

        With -regress_stim_times:

           If the -regress_stim_times option is uses, and if ALL stim files
           are timing files, then timing_tool.py will be used to add the
           time offset to each -regress_stim_times file as it is copied into
           the stimuli directory (near the beginning of the script).

        With -regress_stim_files:

           If the -regress_stim_files option is used (so the script would
           convert -stim_files to -stim_times before 3dDeconvolve), the
           user may want to add an offset to the times in the resulting
           timing files.

           For example, if -tshift_align_to is applied and the user chooses
           to align volumes to the middle of the TR, it might be appropriate
           to add TR/2 to the times of the stim_times files.

           This OFFSET will be applied to the make_stim_times.py command in
           the output script.

        Please see 'make_stim_times.py -help' for more information.
        See also -regress_stim_files, -regress_use_stim_files,
                 -regress_stim_times and -tshift_align_to.

    -regress_stim_types TYPE1 TYPE2 ... : specify list of stim types

            e.g. -regress_stim_types times times AM2 AM2 times AM1 file
            e.g. -regress_stim_types AM2
            default: times

        If amplitude, duration or individual modulation is desired with
        any of the stimulus timing files provided via -regress_stim_files,
        then this option should be used to specify one (if all of the types
        are the same) or a list of stimulus timing types.  One can also use
        the type 'file' for the case of -stim_file, where the input is a 1D
        regressor instead of stimulus times.

        The types should be (possibly repeated) elements of the set:
        {times, AM1, AM2, IM}, where they indicate:

            times:  a standard stimulus timing file (not married)
                    ==> use -stim_times in 3dDeconvolve command

            AM1:    have one or more married parameters
                    ==> use -stim_times_AM1 in 3dDeconvolve command

            AM2:    have one or more married parameters
                    ==> use -stim_times_AM2 in 3dDeconvolve command

            IM:     NO married parameters, but get beta for each stim
                    ==> use -stim_times_IM in 3dDeconvolve command

            file:   a 1D regressor, not a stimulus timing file
                    ==> use -stim_file in 3dDeconvolve command

        Please see '3dDeconvolve -help' for more information.
        See also -regress_stim_times.
        See also example 7 (esoteric options).

    -regress_use_stim_files : use -stim_file in regression, not -stim_times

        The default operation of afni_proc.py is to convert TR-locked files
        for the 3dDeconvolve -stim_file option to timing files for the
        3dDeconvolve -stim_times option.

        If the -regress_use_stim_times option is provided, then no such
        conversion will take place.  This assumes the -regress_stim_files
        option is applied to provide such -stim_file files.

        This option has been renamed from '-regress_no_stim_times'.

        Please see '3dDeconvolve -help' for more information.
        See also -regress_stim_files, -regress_stim_times,
                 -regress_stim_labels.

    -regress_extra_ortvec FILE1 ... : specify extra -ortvec files

            e.g. -regress_extra_ortvec ort_resp.1D ort_cardio.1D
            e.g. -regress_extra_ortvec lots_of_orts.1D

        Use this option to specify extra files to be applied with the
        -ortvec option in 3dDeconvolve.  These are applied as regressors
        of no interest, going into the baseline model.

        These files should be in 1D format, columns of regressors in text
        files.  They are not modified by the program, and should match the
        length of the final regression.

        Corresponding labels can be set with -regress_extra_ortvec_labels.

        See also -regress_extra_ortvec_labels.

    -regress_extra_ortvec_labels LAB1 ... : specify label for extra ortvecs

            e.g. -regress_extra_ortvec_labels resp cardio
            e.g. -regress_extra_ortvec_labels EXTERNAL_ORTs

        Use this option to specify labels to correspond with files given
        by -regress_extra_ortvec.  There should be one label per file.

        See also -regress_extra_ortvec.

    -----------------------------------------------------------------
    3dClustSim options ~3~

    -regress_run_clustsim yes/no : add 3dClustSim attrs to stats dset

            e.g. -regress_run_clustsim no
            default: yes

        This option controls whether 3dClustSim will be executed after the
        regression analysis.  Since the default is 'yes', the effective use
        of this option would be to turn off the operation.

        3dClustSim generates a table of cluster sizes/alpha values that can
        then be stored in the stats dataset for a simple multiple
        comparison correction in the cluster interface of the afni GUI, or
        which can be applied via a program like 3dClusterize.

        The blur estimates and mask dataset are required, and so the
        option is only relevant in the context of blur estimation.

        Please see '3dClustSim -help' for more information.
        See also -regress_est_blur_epits, -regress_est_blur_epits and
                 -regress_opts_CS.

    -regress_CS_NN LEVELS   : specify NN levels for 3dClustSim command

            e.g.     -regress_CS_NN 1
            default: -regress_CS_NN 123

        This option allows the user to specify which nearest neighbors to
        consider when clustering.  Cluster results will be generated for
        each included NN level.  Using multiple levels means being able to
        choose between those same levels when looking at the statistical
        results using the afni GUI.

        The LEVELS should be chosen from the set {1,2,3}, where the
        respective levels mean "shares a face", "shares an edge" and
        "shares a corner", respectively.  Any non-empty subset can be used.
        They should be specified as is with 3dClustSim.

        So there are 7 valid subsets: 1, 2, 3, 12, 13, 23, and 123.

        Please see '3dClustSim -help' for details on its '-NN' option.

    -regress_opts_CS OPTS ...    : specify extra options for 3dClustSim

            e.g. -regress_opts_CS -athr 0.05 0.01 0.005 0.001

        This option allows the user to add extra options to the 3dClustSim
        command.  Only 1 such option should be applied, though multiple
        options to 3dClustSim can be included.

        Please see '3dClustSim -help' for more information.
        See also -regress_run_clustsim.


- R Reynolds  Dec, 2006                             thanks to Z Saad
===========================================================================


This page auto-generated on Thu Apr 18 14:46:12 EDT 2024